![Trustwave SWG 3000 Setup Manual Download Page 7](http://html1.mh-extra.com/html/trustwave/swg-3000/swg-3000_setup-manual_1177394007.webp)
Secure Web Gateway 11.5 Setup Guide
Copyright © 2013 Trustwave Holdings, Inc. All rights reserved.
7
2.1.1
Requirements before Installing a Physical Appliance
•
Working electrical outlet:
•
1 x Outlet for the SWG 3000
•
2 x Outlets for the SWG 5000
•
4 x 16amp Outlets for the SWG 7000, preferably via PDU
•
Network connection — cable and switch
•
Hardware for connecting — ethernet cable, serial cable, or a keyboard and monitor
•
Rack space for the appliance
•
1U Rack space for SWG 3000 or SWG 5000
•
7U Rack space for SWG 7000
•
Switch port for the internet cable
•
Appliance name
•
Physical address
•
DNS address
•
DNS name
•
Default gateway
2.1.2
Connecting an Appliance Using an Ethernet Cable
2.1.2.1
For SWG 3000 and SWG 5000 models:
1.
Plug in the power cable and switch the appliance on.
2.
Connect a PC directly to the appliance’s GE0 port or via a switch (for 5000-SWG, see 5000-SWG Rear
Panel) using a standard (8 thread) Ethernet cable. CAT5e cables (or better) are recommended.
3.
The default IP of the GE0 interface is 10.0.0.1, and its default netmask is 255.255.255.0. Configure
the TCP/IP settings of your PC so that it is on the same logical network subnet as the appliance’s GE0
interface. For example, configure the IP on the PC as 10.0.0.101 and the PC’s netmask as
255.255.255.0.
IMPORTANT:
Do not set the PC’s IP to 10.0.0.1, as this will result in an IP conflict with the appliance.
4.
Continue with initial setup of your SWG Appliance using Limited Shell.