of the louver. During operation, if the power fails 

or the end user shuts down the unit in the turbo 

mode,  the  louver  will  restore  to  the  default 

angle. 

For heat pump models which are provided with 

this  function,  after  running  in  cooling  or  drying 

mode,  if  the  user  press 

Self Clean

  button  on 

remote controller, firstly, indoor unit runs in fan 

only mode for a while, then low heat operation 

and finally runs in fan only again. This function 

can  keep  the  inside  of  indoor  unit  dry  and 

prevent breeding of mold. 

1)

If the indoor PCB receives the signal which

results  from  pressing  the  FOLLOW  ME  button

on  remote  controller,  the  buzzer  will  emit  a

sound and this indicates the follow me function

is  initiated.  But  when  the  indoor  PCB  receives

signal  which sent  from  remote controller  every

3  minutes,  the  buzzer  will  not  respond.  When

the  unit  is  running  with  follow me function,  the

PCB  will  control  the  unit  according  to  the

temperature  from  follow  me  signal,  and  the

temperature  collection  function  of  room

temperature  sensor  will  be  shielded,  but  the

error  detective  function  of  room  temperature

sensor will be still valid.

2)

When the follow me function is available,

the  PCB  will  control  the  unit  according  to  the

room  temperature  from  the  remote  controller

and the setting temperature.

3)

The PCB will take action to the mode

change  information  from  remote  controller

follow: 

When cooling, the setting temperature rises 1

 

(be  lower  than  30

)  every  one  hour,  2  hours 

later  the  setting  temperature  stops  rising  and 

the indoor fan is fixed at low speed.     

When 

heating, 

the 

setting 

temperature 

decreases 1

  (be higher than 17

) every one 

hour,  2  hours  later  the  setting  temperature 

stops rising and indoor fan is fixed at low speed. 

(Anti-cold wind function has the priority). 

3

.4.8.3 Operation time in sleep mode is 7 hours. 

After 7 hours the AC quits this mode and turns 

off. 

3

.4.8.4 Timer setting is available 

3

.4.9 Auto-Restart function 

The  indoor  unit  is  equipped  with  auto-restart 

function,  which  is  carried  out  through  an 

auto-restart module. In case of a sudden power 

failure,  the  module  memorizes  the  setting 

conditions before the power failure. The unit will 

resume  the  previous  operation  setting  (not 

including  swing  function)  automatically  after  3 

minutes when power returns. 

If  the  memorization  condition  is  forced  cooling 

mode,  the  unit  will  run  in  cooling  mode  for  30 

minutes and turn to auto mode as 24

  setting 

temp. 

If AC is off before power off and AC is required 

to  start  up  now,  the  compressor  will  have  1 

minute delay when power on. Other conditions, 

the compressor will have 3 minutes delay when 

restarts. 

3

.4.10 Refrigerant Leakage Detection 

With  this  new  technology,  the  display  area  will 

show 

EC

  when  the  outdoor  unit  detects 

refrigerant leakage. 

3

.4.11 Louver Position Memory Function 

When starting the unit again after shutting down, 

its louver will restore to the angle originally set 

by  the  user,  but  the  precondition  is  that  the 

angle  must  be  within  the  allowable  range,  if  it 

exceeds,  it  will  memorize  the  maximum  angle 

3

.4.12 8

  Heating(optional) 

In heating operation, the preset temperature of 

the  air  conditioner  can  be  as  lower  as  8

which  keeps  the  room  temperature  steady  at 

8

  and  prevents  household  things  freezing 

when the house is unoccupied for a long time in 

severe cold weather. 

3

.4.13 Self clean (optional) 

3

.4.14 Follow me (optional) 

14

Summary of Contents for TC Series

Page 1: ... CONDITIONING EQUIPMENT CO Prepared By Engineering R D Department Shiraz May 2017 INVERTER WALL MOUNTED SPLIT TC SERIES TRUST AIR CONDITIONING EQUIPMENT CO Prepared By Engineering R D Department Shiraz May 2017 ...

Page 2: ...or many years 4 1 6 Re installation while the indoor unit need to be repaired 5 1 7 Re installation while the outdoor unit need to be repaired 6 1 Installation Details 1 1 1 Wrench torque sheet for installation 1 3 2 Display function 10 3 3 Main Protection 11 3 4 Operation Modes and Functions 12 3 Electronic function 10 3 1 Abbreviation 10 2 Operation Characteristics 9 ...

Page 3: ...ld be selected according to the following specifications sheet Rated current of appliance Nominal cross sectional area mm 3 and 6 0 75 6 and 10 1 10 and 16 1 5 16 and 25 2 5 The cable size and the current of the fuse or switch are determined by the maximum current indicated on the nameplate which located on the side panel of the unit Please refer to the nameplate before selecting the cable fuse an...

Page 4: ... 3 8 Ф9 52 1 4 Ф6 35 5 10 25 15 TMST12HT1I3 66 i O 4SW1R1N1S 1 2 Ф12 7 1 4 Ф6 35 5 10 25 15 TMST18HT1I3 52 i O 4SW1R1N1S 1 2 Ф12 7 1 4 Ф6 35 5 20 30 15 TMST24HT1I3 55 i O 4SW1R1N1S 5 8 Ф15 9 3 8 Ф9 52 5 25 50 30 Caution The capacity test is based on the standard length and the maximum permissive length is based on the system reliability 1 3 Pipe length and the elevation 2 ...

Page 5: ... to the vacuum pump 4 Fully open the handle Lo of the manifold valve 5 Operate the vacuum pump to evacuate 6 Make evacuation for 30 minutes and check whether the compound meter indicates 0 1Mpa If the meter does not indicate 0 1Mpa after pumping 30 minutes it should be pumped 20 minutes more If the pressure can t achieve 0 1Mpa after pumping 50 minutes please check if there are some leakage points...

Page 6: ... the vacuum pump to the valve at the bottom of the cylinder If the refrigerant is R410A make the cylinder bottom up to ensure the liquid charge 2 Purge the air from the charge hose Open the valve at the bottom of the cylinder and press the check valve on the charge set to purge the air be careful of the liquid refrigerant 3 Put the charging cylinder onto the electronic scale and record the weight ...

Page 7: ...r purging of the charge hose Open the handle Lo valve of the manifold valve slightly to purge air from the charge hose for 5 seconds and then close it quickly 4 Set the 2 way valve to the close position 5 Operate the air conditioner at the cooling cycle and stop it when the gauge indicates 0 1MPa 6 Set the 3 way valve to the closed position immediately Do this quickly so that the gauge ends up ind...

Page 8: ...e hose to the charging cylinder open the 2 way valve and the 3 way valve Connect the charge hose which you disconnected from the vacuum pump to the valve at the bottom of the cylinder If the refrigerant is R410A make the cylinder bottom up to ensure liquid charge 2 Purge the air from the charge hose Open the valve at the bottom of the cylinder and press the check valve on the charge set to purge t...

Page 9: ...port Use torque wrench to tighten the service port cap to a torque of 18N m Be sure to check for gas leakage 7 ...

Page 10: ...ove conditions certain safety protection features may come into operation and cause the unit to operate abnormally 2 The room relative humidity should be less than 80 If the air conditioner operates beyond this figure the surface of the air conditioner may attract condensation Please set the vertical air flow louver to its maximum angle vertically to the floor and set HIGH fan mode 3 The optimum p...

Page 11: ...ration Dispalys when anti cold air feature is activated under heating mode Dispalys during self clean operation if aplicable Dispalys under 8 heating operation if aplicable Optional According to the operation mode the indicator displays different colour Under Cool or Dry mode it displays as cool colour Under Heat mode it displays as warm colour if aplicable Energy saving display Displays when the ...

Page 12: ...fan will open 7s later If the unit runs in heating mode the indoor fan will be also controlled by anti cold wind function 3 3 7 Compressor preheating functions Preheating permitting condition When T4 outdoor ambient temperature 3 C the preheating function will be activated 3 3 8 Sensor protection at open circuit and breaking disconnection When there s only one temperature sensor in malfunction the...

Page 13: ...H H B C M M M Z D M M M E F L L L D G L L L H I T1 Td F L L L L D H H H H G M M M M Z The auto fan acts as below rules a b c d T 1 e Resume Off Decrease Hold Increase 3 4 Operation Modes and Functions 3 4 1 Fan mode 1 Outdoor fan and compressor stop 2 Temperature setting function is disabled and no setting temperature is displayed 3 Indoor fan can be set to high med low auto 4 The louver operates ...

Page 14: ...F L L L D G L L L H I T1 Td F L L L L D H H H H G M M M M Z Auto fan action in heating mode a b c d T 1 e lighted Will be displayed If any one of the following items is satisfied the defrosting will finish and the machine will turn to normal heating mode T3 rises to be higher than TCDE1 T3 keeps to be higher than TCDE2 for 80 seconds The machine has run for 15 minutes in defrosting mode 3 4 2 5 Ev...

Page 15: ...g temperature can be changed between 17 C 30 C In auto mode the machine will choose cooling heating or fan only mode according to ΔT ΔT T1 Ts 3 4 5 Drying mode Indoor fan speed is fixed at breeze and can t be changed The louver angle is the same as in cooling mode All protections are active and the same as that 3 4 7 Timer function 3 4 7 1 Timing range is 24 hours 3 4 7 2 Timer on The machine will...

Page 16: ...erature decreases 1 be higher than 17 every one hour 2 hours later the setting temperature stops rising and indoor fan is fixed at low speed Anti cold wind function has the priority 3 4 8 3 Operation time in sleep mode is 7 hours After 7 hours the AC quits this mode and turns off 3 4 8 4 Timer setting is available 3 4 9 Auto Restart function The indoor unit is equipped with auto restart function w...

Page 17: ...temperature will control the unit according to the room temperature detected from its own room temperature sensor and setting temperature Press the silence button on remote controller to initiate SILENCE function When the Silence function is activated the compressor running frequency will keep lower than F2 and the indoor unit will bring faint breeze which will reduce the noise to the lowest level...

Page 18: ...serve 3 Reserve 4 Reserve 5 Reserve 6 Reserve L Reserve A Reserve U Reserve T When the AC enter into the information enquiry status it will display the code value in the next 25s the details are as follows 3 4 16 Point check function Press the LED DISPLAY or LED or MUTE button of the remote controller three times and then press the AIR DIRECTION or SWING button three times in ten seconds the buzze...

Page 19: ...139 E0 E1 E9 140 141 149 F0 F1 F9 150 151 159 Indoor fan speed Outdoor fan speed 0 OFF 1 2 3 4 Low speed Medium speed High speed Turbo For some big capacity motors 14 FF Actual fan speed Display value turns to decimal value and then multiply 10 The unit is RPM For some small capacity motors display value is from 14 FF hexadecimal the corresponding fan speed range is from 200 2550RPM EXV opening an...

Page 20: ...36341070 Fax 98 71 36341094 Tehran office No 19 koohe nour St Motahhari St TEHRAN IRAN Post code 15876 73111 Tel 98 21 89389 Fax 98 21 88541903 Ahwaz office No 309 Kaveh St AHWAZ IRAN Post code 61939 47911 Tel 98 61 32230647 8 Fax 98 61 32230647 E mail info trustacs com Web site http www trustacs com Air Conditioning Systems Cooling Heating ...

Reviews: