8
Use only spare parts and accessories recommended by the manufacturer. In
the event the tool is not working take it to repairs in a
Authorized Service Center.
Maintenance
Repairs
• Always disconnect the tool before cleaning it.
• Never use water or other liquids. Use a brush only.
• To prevent motor overheating clean regularly the ventilation slots.
• Double-check the entire tool components are perfectly tight.
• The tool housing shall not be cracked or damaged.
• Always verify the power cord is not cut or peeled.
• After a prolonged time of use, the grease in the head shall need to be
changed. Go to a Authorized Service Center to service it.
• Carbon brushes need to be replaced. Replace with new carbons when worn,
burnt, broken or smaller than 0.19” long.
• When replacing always replace both carbon brushes.
• Remove worn carbon brushes off the carbon housing. Remove accumulated
dust with compressed air.
• Set the new carbon brushes reversing the order. Carbons shall drop easily in
the carbon housing.
• After setting the new carbons run the car polisher a few minutes with no load
to get better fit.
• Use only original replacement carbon brushes
specifically designed with the hardness and electric resistance for each type of
motor. Carbon brushes that are out of specification may damage the motor.
Carbon brush replacement
ENGLISH
Neatly store the tool in a dry place and protected from dust and water .