REGULATE VALVE
WRONG INSTALLATION
INSTALLATION
ELECTRIC DIAGRAM
R
JOINER NUT
CONCRETE BASE
SUCTION PIPING
SUPPORT
FOOT VALVE
MINIMUM LEVEL
19.6”
RIGHT INSTALLATION
SAND BOX
GUIDELINES FOR EXTENSION CORDS
Make sure the extension cord is in good shape. When using an
extension cord, verify the gauge is enough for the power that your
product needs. A lower gauge cord will cause voltage drop in the
line, resulting in power loss and overheating.
The following table shows the right size to use depending on the
cord´s length and the ampere capability shown in the tool’s
nameplate. If in doubt, use the next higher gauge. The lower the
gauge, the heavier the cord will be.
Make sure that your extension cord is properly grounded and in
good shape.
(1) It is safe to use only if the extensions themselves have an artifact for over current protection.
(2) One of the conductors should be grounded. All conductors are the same gauge including the one that is grounded.
Reference: NMX-J-195-ANCE-2006
Ampere Capacity
(2)
Higher than
0 A
10 A
13 A
15 A
Up to
10 A
13 A
15 A
20 A
Number of
Conductor
3
3
3
3
From 5.9’ to
49.2’
18 AWG (1)
16 AWG
14 AWG
8 AWG
Higher than 49.2’
16 AWG
14 AWG
12 AWG
6 AWG
Extension Gauge
4
Failure to follow with these caution advices may damage the pump and void the warranty.
PROBLEM
The motor does not start.
The motor runs without
pumping water.
Flow speed is not enough.
The motor overload short
is activated
CAUSE
- There is no energy.
- Blocked impeller.
- Clogged filter.
- Excessive height in the suction.
- Air in the admission.
- Suction height is in the limit.
- Filter is partially clogged.
- Blocked impeller.
- Motor overload.
- Stuck impeller.
SOLUTIONS
- Check the connections and the power values
- See the maintenance section
- Clean the filter
- Reduce the suction pipe length.
- Double-check the suction pipe is hermetic.
- Check the foot valve is submerged at least 19.6”
- Priming the pump back is required.
- Verify the suction height.
- Shorten the suction pipe length.
- Clean the foot valve and the whole suction pipe is necessary.
- Release the impeller (See maintenance section)
- Double-check power and ventilation.
- Release the impeller ( see the maintenance section)
TROUBLESHOOTING