• The connection to the power source shall be carried out by a
professional electrician and should follow the electric diagram shown to the right.
operating and ground shall not be disconnected before finishing the welding job;
• The gauge in the ground conducting cable cannot have a lower
Ground
connection bolt
˜
F
Input diagram in the connections board
220 V˜
110 V˜
R
S
R
S
Output
Power source
input
(220 V˜ or 110 V )
3
Technical data
Power requirements
• Always confirm that the input connection
board configuration matches with the voltage of the power
supply to which the welding machine will be connected (110 V˜
or 220 V˜). The connection screws shall be tightly fastened.
• The power source shall meet the following
requisites:
CAUTION
CAUTION
CAUTION
• The welding machine shall be perfectly grounded before
otherwise the operator may receive an electric shock and get severely injured.
• There shall be a parallel connection when the tool is using the same ground
together with other tools. Never connect a series of devices.
gauge then the power cable.
* The fuse fusion current is double of its rated current.
CAUTION
WARNING
Switch
Power cord
60 A
0.009 in
2
If extensions are required between the welding machine and the
work piece, the welding cord gauge shall be increased in order to
keep the welding machine energy output with a potential drop not
higher than 4 V˜
ENGLISH
WARNING
WARNING
Avoid the risk of electric shock or severe injury. When the power cable gets damaged
it should only be replaced by the manufacturer or at a Authorized Service Center.
The build quality of the electric insulation is altered if spills or liquid gets into the tool while in use.
Do not expose to rain, liquids and/or dampness.
Before gaining access to the terminals all power sources should be disconnected.
13107
50 V˜
Fan
60 Hz
Stick welder
Code
Description
Voltage
Frequency
Current
Power
Rated voltage with no load
Power Cord Grips: Type Y
Tool Build Quality: Basic insulation.
The class of thermal insulation of the windings: Class H
110 V˜
220 V
66 A
46 A
7,3 kVA
10 kVA
˜
60 A - 180 A
60 A - 130 A
Current adjust range
Type of cooling
Insulation
Class I
SOT-250CL
Input
Output
1 minute work per 9 minutes rest.
Output values specified are with a 68 ºF Temperatures higher than the work cycle may be reduced.
Duty cycle
IP21S
IP Grade