![Trumpf N 700-0 Operator'S Manual Download Page 18](http://html1.mh-extra.com/html/trumpf/n-700-0/n-700-0_operators-manual_1176316018.webp)
18
Maintenance
E210EN_03.DOC
5.1 Changing the tool
Replace the tools when the punch and/or die are blunt and can no
longer be reground.
Disassembling the punch
1. Loosen clamping screw (36).
2. Rotate die carrier (7) by 45°.
3. Pull die carrier (7) out towards the bottom.
4. Remove punch (9) by rotating it.
Installing the punch
1. Lightly lubricate the square part of the punch and die carrier
bore hole with lubricating grease "S1" TRUMPF Order
No. 121486.
2. Ensure that penetration depth is correct.
Changing the die and the punch guide
1. To replace the die and the punch guide, unscrew the fixing
screws (4).
2. Clean support areas on the die carrier (7).
3. Take care to ensure that the replacement parts are clean.
4. Lubricate the guide surfaces of the punch guide with lubricating
grease "S1" TRUMPF Order No. 121486.
5. Screw the fastening screws tightly when mounting the die and
the punch guide. (Tightening torque 16.5 Nm)
Use original screws only!
(see Fig. 9016, Pg. 16)