background image

2

GB

N 200-5

E415EN1_2.DOC

For your safety

Safe operation of the appliance is only
possible when the operator's manual and the
supplied safety information (red print,
TRUMPF order no. 125699) have been
completely read and the instructions
contained within have been strictly adhered
to.

 

 
 

Danger of injury

 
Check the unit, compressed-air tube and
reception coupling before each use.
 Have all damaged parts repaired by an
expert.

 
 

Danger of injury

 
Hot chips are ejected from the chip ejector at
extremely high speeds. You should therefore
use a swarf box to collect the ejected chips.

Always wear safety glasses, hearing
protection, protective gloves, and hard
shoes when operating.

  Do not connect the compressed air unless the

machine is turned off.

  Always disconnect the compressed-air tube from

the machine before beginning any work on the
machine!

  Always guide the compressed-air tube back away

from the unit.

 

Use only original TRUMPF accessories.

Before putting the machine into
service

1.  Read the chapter on safety.

For your safety

2.  Replace blunt tools.

Tool changes

3. The flow pressure of the compressed air must be

6 bar at the point of extraction.

4. Oil lubrication must take place for the

compressed-air motor.

Maintenance

Operating istructions

Damage to the machine!

Check the tools for wear and the oil
lubrication of the compressed-air motor
every hour.

Never work with blunt tools!

(the compressed-air motor may stop).

Switching on and off

Fig. 26691

Turning on the unit:

  Press lever 1.

Turning off the unit:

  Release lever 1

(the lever springs back into initial position and the
flow of compressed air is interrupted).

1

1

Lever

Reviews: