4. Mechanical elements
4.1
Maintenance Instructions
Safety fencing
Maintenance interval: Every 6 months
Ø
Check polycarbonate windows for damage. In case neces-
sary: request Technical Service.
Maintenance interval: Every 6 months
Means, Tools, Materials
■
Anti static plastic cleaner (mat. no. 1672922).
Ø
Clean the polycarbonate panes with anti-static plastic cleaner.
Lift gate
Maintenance interval: Every 6 months
No maintenance work is required on any of the guide elements
(guide carriage and guide rail; toothed wheel and rack)
1. Check the lift gate for damage.
2. Manually open the lift gate in manual mode.
3. Check the control unit of the lift gate of the upper end posi-
tion. Correct display:
¯.Eo¯
.
4. Manually close the lift gate in manual mode.
5. Check the safety bar for proper function. The lift gate has to
open itself again.
6. Manually close the lift gate in manual mode.
7. Check the control unit of the lift gate of the lower end posi-
tion. Correct display:
_.Eu_
.
8. Carry out steps 1 to 7 on all lift gates.
Maintenance interval: Every 6 months
No maintenance work is required on any of the guide elements
(guide carriage and guide rail; toothed wheel and rack)
5
‐
10
Mechanical elements
2015-06-01
B579EN
106274:
Checking polycarbonate
windows for damage
106613:
Cleaning the polycarbonate
panes
106614:
Checking the lift gate
without store interface
106618:
Checking the lift gate with
store interface
Summary of Contents for BendMaster 150
Page 1: ...Operator s manual BendMaster TruBend Cell 5000...
Page 2: ......
Page 3: ...Operator s manual BendMaster TruBend Cell 5000 Original operator s manual Edition 2015 06 01...
Page 6: ...II Before you proceed 2015 06 01 B579EN...
Page 16: ...0 10 Table of contents 2015 06 01 B579EN...
Page 44: ...1 28 Disassembly and disposal 2015 06 01 B579EN...