Specification
Outputs
VALUE
EN: 4-20 mA analogue output using setpoint 1.
Note:
DC PSU ONLY
DE: 4-20 mA Analogausgang mit Sollwert 1.
FR: Sortie analogique 4 à 20 mA via le point de consigne 1.
ES: 4-20 mA salida analógica utilizando punto de ajuste 1.
IT: Uscita analogica 4-20 mA con valore di riferimento 1.
EN: Using a diode-protected relay on setpoint 1.
Note:
DC PSU ONLY
DE: Mit einem diodengeschützten Relais auf Sollwert 1.
FR:
Utilisation d’un relais avec diode de protection contre l’inversion de
polarité au point de consigne 1.
ES: Usando un relé de diodo protegido en punto de ajuste 1.
IT: Utilizzare un relè protetto da diodo su valore di riferimento 1.
EN: Analogue Output and relay using both setpoints.
Note:
DC PSU ONLY
DE: Analogausgang und Relais mit beiden Sollwerten.
FR: Sortie analogique et relais utilisant les deux points de consigne.
ES:
Salida analógica y el relé usando ambos puntos de ajuste.
IT:
Uscita analogica e relè con entrambi i valori di riferimento.
EN: Use the Reset input with the peak hold function
Note:
DC PSU ONLY
DE: Verwenden Sie den Reset-Eingang mit der Peak-Hold-Funktion
FR:
Effectuer l’entrée de réinitialisation via la fonction de maintien de la
valeur de crête
ES: Utilice la entrada Reset con la función de mantenimiento de pico
IT: Utilizzare l'ingresso di reset con la funzione Mantieni
Environment
Temperature - operating
–10 to +60 deg C
Temperature - storage
–40 to +70 deg C
Altitude
2000 metres
Relative Humidity (non-condensing) - Continuous
0
– 85 %
Relative Humidity (non-condensing) - Intermittent
0
– 95 %
Pollution Degree (IEC664)
2
IP rating (from the front)
IP65
NEMA Rating (from the front)
Type 4 & Type 12
Vibration
Shock
Power supply
Input
12-24V DC +/-10%
Max Power
1.6W
Supply Frequency
DC
Isolation
None
Display
Number of digits
4
Digit height
12 mm
Number of bar-graph segments
40
Number of starburst message characters
4
Backlight colours
Red, Green, White
LCD
Positive or negative
Digit update frequency
0.08
– 21 sec
Bar-graph update frequency
0.08
– 21 sec
Viewing angle
+/-70° Horizontal
+/-70° Vertical
Open Collector Outputs
Max voltage (open collector outputs)
34 V
Max current (open collector outputs)
500 mA
Analogue Output
Output
4-20 mA
Accuracy
0.50 %
Resolution
0.02 mA
Connections
Type
Screw Terminals
Wire type
Solid or Stranded
Min. cable temperature rating
65 deg C (149F)
Wire strip length
6.5mm to 7mm
(0.26” to 0.28”)
Wire gauge
0.8mm² - 3.3mm²
(18AWG to 12AWG)
Torque
0.5-0.6Nm
(4.42-5.31 lbf-in)
Certification
CE
cULus
IEC 61010-1
In the Box
APM
Getting started & safety guide
Gasket
Retaining clip
Panel Cut-out:
68 x 68 mm (2.68 in) +0.7 -0 mm
(0.02 in).
Max. panel thickness
: 10 mm.
Dimensions:
Depth behind panel inside front: 55mm
(2.17in) incl. external connections.
Weight:
180 grams.
-
+
12 to 24V
DC
PSU
Fuse
0V
4-20mA
Output
-
+
12 to 24V
DC
PSU
Fuse
RELAY
+
-
-
+
12 to 24V
DC
PSU
Fuse
RELAY
+
-
0V
4-20mA
- ~
+ ~
12 to 24V
AC or DC
PSU
Fuse
Wiring Diagrams
CURRENT INPUT
Ground referenced
DC POWERED (12 to 24V)
CURRENT INPUT
Ground Referenced
DC POWERED (12 to 24V)
WITH SETPOINT OUTPUT
CURRENT INPUT
Ground Referenced
DC POWERED (12 to 24V)
WITH EXTERNAL RESET
-
+
12 to 24VDC
PSU
Fuse
NOTE:
Max Voltage 1.5V
Referenced to
COM Terminal
SHUNT
-
+
12 to 24VDC
PSU
Fuse
SETPOINT 1
OUTPUT
SHUNT
0V
NOTE:
Max Voltage 1.5V
Referenced to
COM Terminal
-
+
12 to 24VDC
PSU
Fuse
SHUNT
NOTE:
Max Voltage 1.5V
Referenced to
COM Terminal
www.
GlobalTestSupply
.com
Find Quality Products Online at: