Truma Ultrastore Operating And Installation Instructions Download Page 5

2

Maintenance

Note:

The water tank in the

Truma-Ultrastore is made of
high quality food-proof stain-
less steel VA.

Use wine vinegar for de-scal-
ing the water heater, this be-
ing introduced into the appli-
ance via the water supply. Al-
low the product to react and
then thoroughly flush out the
appliance with plenty of fresh
water. To sterilise the water
we recommend „Certisil-Ar-
gento”. Other products, par-
ticularly those containing
chlorine are unsuitable.

In order to avoid the prolifera-
tion of micro-organisms, heat
the Ultrastore to 70°C at reg-
ular intervals.

Do not use the water as
drinking water!

Fuses

The water heater fuse is on
the electronic control unit on
the water heater.

Important note:

Only re-

place the miniature Fuse on
the p.c.b. with a fuse of the
same type: 1.6 AT 
EN 60127-2-3 (slow action).

If there is a defect in the elec-
tronics, return the control
p.c.b. well padded. If you fail
to pack it correctly the guar-
antee shall no longer be valid.

Only use original Truma-Ultra-
store control p.c.b.'s as spare
parts!

while. Remedial action here
is to immediately run the
heater and to ensure ade-
quate room ventilation.

7. Items sensitive to heat
(e.g. spray cans) must not be
stored in the installation area,
since excess temperatures
may under certain circum-
stances be incurred there.

8. If the burner makes an un-
usual noise or if the flame
lifts off, it is likely that the
regulator is faulty and it is
essential to have it checked. 

9. For the gas system, only
gas pressure regulators with
protection against excess
pressure, such as regulators
with safety valves according
to DIN 4811 and VP 306, may
be used. We recommend the
Truma DUB vehicle regulator
or in the case of a two cylin-
der gas installation that is 
only accessible from the out-
side, the Truma Triomatic au-
tomatic reserve switch-over.
The Truma regulators have
been specially designed for
heavy duty use in caravans,
boats and vehicles. In addi-
tion to a safety valve for
countering excess pressure,
they also have a pressure
gauge with which you can
check that the installation is
fully gas tight.

Always connect the pressure
regulators to the gas cylin-
ders by hand, using great
care! For temperatures
around 0°C and below, the
regulators should be operat-
ed with a defroster system
(Eis-Ex). Inspect regulator
connection hoses regularly
for signs of weakness. 
For winter operation only use
special frost-resistant hoses.
Gas cylinders must always
stand upright!

General safety 
notes

In event of leaks in the gas
system or if there is a smell of
gas:

- extinguish all naked 

flames!

- do not smoke!
- switch off the appliances!
- close gas cylinder!
- open the windows!
- do not operate any 

electrical switches!

- have the entire system 

checked by an expert!

Repair jobs are only
to be carried out by
an expert.

1. Any alteration to the appli-
ance (including cowl) or the
use of spare parts and acces-
sories which are important for
the functioning of the heater
and which are not original
Truma parts, as well as the
non-observance of the instal-
lation and operating instruc-
tions, shall lead to the can-
celling of the guarantee and
exclusion of liability claims. It
also becomes illegal to use
the appliance, and in some
countries this even makes it
illegal to use the vehicle.

2. The operating pressure for
the gas supply is 30 mbar (or
28 mbar butane/37 mbar
propane) and must corre-
spond to the operating pres-
sure of the appliance (see da-
ta plate).

3. In Germany only

LPG

systems must comply with
the DVGW form G 607.

The gas system must be 
tested every 2 years

by a 

liquid gas expert (DVFG, TÜV,
DEKRA). This inspection must
be confirmed on the test cer-
tificate in accordance with
the DVGW-form G 607. 

The vehicle owner is al-
ways responsible for ar-
ranging the inspection.

4. In other countries,

the

respectively valid regulations
must be observed. For your
own safety it is absolutely
necessary to have the com-
plete gas installation regularly
checked by an expert (at least
every 2 years).

5. Do not operate the water
heater when refuelling the ve-
hicle and when in the garage.

6. During the initial operation
of a brand new appliance (or
after it has not been used for
some time), a slight amount
of fumes and a slight smell
may be noticed for a short

Technical data

Water contents:

10 litres

Water pressure:

up to max. 2.8 bar

Type of gas: 

Liquid gas (propane/butane)

Operating pressure: 

30 mbar (or 28 mbar butane/
37 mbar propane)

Rated thermal output:

1500 W

Gas consumption:

120 g/h

Heating time 
up to approx. 70°C

Gas operation: approx. 35 min.
electrical operation: 
approx. 70 min.
Gas and electrical operation:
approx. 20 min.

Power consumption 12 V

Ignition: 0.17 A
Heating up: 0.08 A
Standby: 0.04 A

Power consumption 230 V

Heating up: (2 A) 450 W

Weight (empty):

approx.: 6.7 kg

Declaration of conformity:

The Truma-Ultrastore model
has been tested and ap-
proved through the DVGW
and fulfils the EC gas appli-
ance guidelines (90/396/EEC)
as well as the associated EC
guidelines. The CE product
number is available for EU
countries: 

CE-0085AP0038

Summary of Contents for Ultrastore

Page 1: ...der dem Truma Service in Ihrem Land angefordert wer den Operating instructions Installation instructions To be kept in the vehicle Page 1 Bruks och monterings anvisningar p svenska kan rekvireras fr n...

Page 2: ...Installation example 1 Truma Ultrastore 2 Control panel 3 Safety drain valve 4 Cowl for combustion air intake and exhaust gas discharge US 2 Ultrastore Gas and Electric Storage Water Heater 1 2 4 3...

Page 3: ...US 3 Ultrastore Gas and Electric Storage Water Heater 23 20 15 16 22 14 13 24 6 A C F E D Direction of travel 12 23 20 15 16 22 14 13 24 B...

Page 4: ...en 3 Open safety drain valve Lever in vertical position po sition f 4 The water heater is now drained directly to the outside via the safety drain valve Check that the water con tents have been comple...

Page 5: ...nt hoses Gas cylinders must always stand upright General safety notes In event of leaks in the gas system or if there is a smell of gas extinguish all naked flames do not smoke switch off the applianc...

Page 6: ...ter is more than 35 mm you must use the cowl extension VBO 2 Art no 70131 00 with an additional length of 50 mm Saw out 100 x 176 mm along the dashed line If there are any cavities in the area of the...

Page 7: ...eter for leading through the cable and pass the cable through the hole Fasten con trol panel with the two screws and route the cable to the appliance 5 Electrical connection 12 V Always disconnect th...

Page 8: ...g the device to the manufacturers or send it to them If there is damage to heaters heat exchangers the gas pressure regulator must also be sent back to the factory In instances of the device be ing se...

Page 9: ...public KOV Karos rna a sl v rna Velim Tel 0321 76 35 58 Danmark A C Lemvigh M ller Kopenhagen Tel 03311 05 32 Finland Keh Caravan Tukku Oy Espoo Tel 09 84 94 30 34 France Euro Accessoires Tournon Tel...

Page 10: ...s a whole Today Truma is the interna tionally acknowledged brand leader operating on the basis of the certified quality man agement system according to ISO 9001 To be filled in by the dealer Date of s...

Reviews: