Fault finding

Gas operation

Symptom

Cause

When switching on, the heat-
er does not operate.

 

– No 12 V supply voltage.

Check the power supply (operation voltage min. 10.5 V).
Check the Truma UltraRapid HWS fuse (refer to maintenance 
“Fuses”).

When switching on, the heat-
er does not operate and the 
red lamp lights up 
after approx. 30 secs. 

 

– Cowl cover fitted. 

 

– Air in the gas supply.

 

– No gas supply. 

 

– Incorrect gas pressure.

Remove cowl cover and / or clear any obstruction. 
Check gas valves and gas cylinder.
To unlock (and purge air), switch off the appliance, wait 
5 minutes, and switch on again.

Heater operates for a pro-
longed time and then 
the red lamp lights up.

 

– Excess temperature 

thermostat has responded.

Check water level, refill if required (close drain valve).
To unlock, switch off the appliance, wait 5 minutes, and 
switch on again.

Electrical operation

Symptom

Cause

When switching on, the 
heater does not operate.

 

– No 240 V supply voltage.

 

– Excess temperature 

thermostat has responded.

Connect the caravan to the site supply and / or check residual 
current circuit breaker.
Check water level, refill if required (close drain valve).

The electrical heating element is fitted with an excess tem-
perature cut-out. In the event of a fault, switch off at the 
control panel, wait 10 minutes, then switch on again.

Water supply

Symptom

Cause

Water drips from the 
P&T safety valve.

 

– Water pressure to high.

 

– Lime or dirt under the 

P&T safety valve seat.

Check water pressure (max. 400 kPa), use a pressure reduc-
er when connected to central water supply.

Allow the appliance to cool and then slowly raise the test 
lever (Fig. 2a – 4a) to flush the water system and attempt to 
force dirt or foreign matter out of the P&T safety valve seat. 

Replace P&T safety valve. This must be performed only by a 
certified service technician.

When opening the cold 
water tap, hot water 
comes out.

 

– Hot water flows back 

through the cold water 
supply.

Fit a non-return valve in the cold water supply (refer to instal-
lation instructions “Water connection”).

If fault persists, please contact the nearest Dometic Service.

Technical data

Protection type / protection class 

IP21 / class I

Water capacity

14 litres

Rated water pressure

400 kPa

Maximum working water pressure / P&T safety valve setting

500 kPa – 99 °C – 10 kW

Type of gas

LPG (Propane)

Test point pressure

2.75 kPa

Nominal heat input

5.0 MJ/h (H

S

)

Nominal heat output

1.2 kW

Gas consumption

96 g/h 

Injector size

0.70 mm

Heating up time from approx. 20 °C up to approx. 65 °C

(14 litres)
Gas operation: approx. 45 min.
Electrical operation: approx. 40 min.
Gas and electrical operation: approx. 28 min.

Power consumption 12 V 

Ignition: 0.160 A
Heating up: 0.12 A
Stand-by: 0.05 A

Power consumption 230 V ~ / 240 V ~

Heating up: 5.7 A / 5.9 A, 1300 W / 1415 W

Weight (empty) 14 litres

BGA:  

 

7.7 

kg 

BGA with peripheral devices:  

8.6 kg 

BGEA:  

 

8.1 

kg 

BGEA with peripheral devices: 

9.1 kg 

 Water pressure reducer 

Flow range water:   0 – 10 litres/min.
Maximum inlet pressure: 

700 kPa

Maximum outlet pressure:  200 kPa

 

The right to make technical modifications is reserved!

Dimensions 

cut out

245

129

324

168

47

30

109

24

255

18

Fig. 7

water
connections

gas connection
with test point

electronic

cowl

cut out

PTR Valve
connection

360

347

92

383 

174

Minimum 120 

Fig. 8

(All dimensions in mm)

Summary of Contents for UltraRapid

Page 1: ...Operating instructions Page 4 Installation instructions Page 8 To be kept in the vehicle Truma UltraRapid Hot Water System LPG and 230 V 240 V Electric Storage Water Heater...

Page 2: ...lt finding 6 Technical data 6 Truma warranty policy 7 Installation instructions Data label 8 Intended use 8 Regulations 8 Water heater kit 8 Choice of location 8 Installation of the water heater 8 Wat...

Page 3: ...the P T safety valve is to be installed in a continuously downward direction and in a frost free ambient Before accessing terminals please ensure all supply circuits are disconnected i e 230 V 240 V...

Page 4: ...tire water supply through with clean warm water Always mount the cowl cap when the water heater is not being operated Drain the water heater if there is a risk of frost Warranty claims will not be acc...

Page 5: ...ease refer to page 5 Fault finding To unlock switch off the appliance wait 10 minutes and switch on again Electrical operation 230 V 240 V option 230 V 240 V 1300 W 1415 W 5 7 A 5 9 A The Truma UltraR...

Page 6: ...ly Allow the appliance to cool and then slowly raise the test lever Fig 2a 4a to flush the water system and attempt to force dirt or foreign matter out of the P T safety valve seat Replace P T safety...

Page 7: ...check carefully the operating instructions warranty terms and conditions If the product fails for any of the reasons detailed therein or is faulty due to abuse misuse or improper installation then a s...

Page 8: ...unt sealing frame 3 the anti twisting device ensures correct fitting Pre drill holes for the 6 fastening bolts 4 Installation of the unit may only be carried out by properly qualified professionals Th...

Page 9: ...ater and the resulting expansion All hot water pipes should be routed in a descending man ner to the drain valve Otherwise there is no guarantee of protection from frost Installation of the pressure r...

Page 10: ...valve 14 and elbow 13 lower pipe on water heater Pressure reducer B The pressure reducer 10 must be fitted between the drain valve and water pump in accordance with the direction of flow indicated by...

Page 11: ...not possible use the surface mounting frame 25 as supplied Electrical connection 12 V Disconnect device from power supply before starting to work on electrical components Switching off at the control...

Page 12: ...cable supply cord is damaged it must be replaced by the manufacturer its service agent or simi larly qualified persons in order to avoid a hazard Fig 21 In order to operate the element the manufacture...

Page 13: ...13 BGA 14 BGEA 14 LPG Propane and 230 V 240 V Electric Storage Water Heater When ordering spare parts please always state the serial number and year of manufacture...

Page 14: ...rown BU blue GN green GY green yellow OG orange RD red WH white YE yellow WH BN GN YE GY Electrical Connection Diagram Truma UltraRapid Hot Water System Safety Valve PC Push Coil HC Holding Coil RD GN...

Page 15: ...15...

Page 16: ...elevant service partners should be contacted www truma com Having the equipment model and the serial number ready see type plate will speed up processing Service Australia Telephone 61 0 3 92 39 10 50...

Reviews: