EQUIPMENT DET
AILS
90
The intelligent heat management system
operation in dual fuel mode and allow the
Truma Combination boiler to prioritize the
electric power source over your gas, which all
conserve your gas supply.
Truma Combi 4E
1 Control panel
2 Power selector switch
3 Optional timer
4 Room temperature sensor
5 Cold water connection
6 Hot water connection
7 Gas connection
8 Hot air outlets
9 Recirculated air intake
10 Waste gas discharge
11 Combustion air infeed
12 Electronic control unit
13 Water container (10 litres)
14 Burner
15 Heat exchanger
16 Power electronics
17 Heating elements 230 V
18 Overheating switch 230 V
Function description
The liquid gas heater ‘Truma Combi’ is a
warm-air heater with integrated hot water
boiler (10 litre volume). The burner operates
fan-supported, which ensures trouble-free
function even when on the move.
In winter operation the heater can be used to
heat the room and simultaneously warm water.
If only warm water is required, select
summer operation.
• In summer operation, the water contents are
heated in the smallest burner stage. Once
the water temperature is reached, the burner
switches off.
• In winter operation, the unit automatically
selects the required power setting according
to the temperature difference between the
temperature set on the control panel and the
current room temperature. When the boiler
is filled, the water is automatically heated as
well. The water temperature depends on the
selected operational mode and the heater
output.
At a temperature of approximately 3° C at the
automatic FrostControl safety/drain valve, the
valve will open and drain the boiler.
The unit is not suitable for use as a flow heater.
Safety instructions
If the gas system is leaking or if there is a
smell of gas:
• extinguish all open flames
• open windows and door
• close all quick-acting valves and gas
cylinders
• do not smoke
• do not activate any electric switches
• ask an expert to inspect the entire system!
Repairs may only be carried out by an
expert!
Any modifications to the unit, including
accessories, exhaust duct, and cowl, or the
use of spare parts and accessories that are
important to the operation of the system
TRUMA COMBI 4E