3 Communication between the PC and the device. 

–  Field flashes green – faulty communication. 

–  Field shines red – interruption.

Show error detail

Any errors are marked in red on the screen.

1

4

3

2

1 Show the error details 

by clicking the field 

marked in red.

or 

 Show the error details 

by clicking the “Error” 

tab.

3 Detailed description of 

the error. 

4 Return to the  

“Live Display” pro-

gram by clicking the 

“Live Display” tab. 

Set operating status

Certain operating parameters can be set for examinations.

For the Combi 4 (E) / Combi 6 (E) devices this is e.g. the field 

“Burner” or “ULMotor”. If the cursor is moved over this field, 

the cursor changes from an   arrow to   a hand.

Combi 4 (E) / Combi 6 (E)

1

2

1 Click the field 

“Burner” to change 

the parameters of the 

burner.

Set the speed of 

the “ULMotor” 

(D.C motor) to min. 

5 % otherwise the 

heater may cut out 

due to overheating.

or 

 Click the field 

“ULMotor” to change 

the parameters of the 

D.C. motor.

End program

1

1  Open the menu “File” 

and leave the program 

by pressing “End”.

Disconnect the diag-

nosis cable from the 

test object.

Switch device off.

“Live Display” program

Show or change the operating statuses and parameters

Prerequisites for operation:

Device

from index

Combi 4 (E)

Combi 6 (E)

4/1A

6/1A

4/11

6/11

4/1

6/1

4/13

6/13

Combi D

Mover®

Start program

The 

“Diagnose Tool”

 program may not be active, it 

must be closed first.

Combi 4 (E), 6 (E): 

Operate the device in heating mode with 

the D.C. motor due to overheating. To do this, set the rotary 

knob for the room temperature to “5” on the control panel.

1

Combi Live Display

2

1 Double-click the icon 

on the desktop.

or

 

 A start screen is shown 

whilst the program is 

loading.

Search for device

1

1 Open the “Tools” 

menu and click “Start” 

to start the search.

After a successful search, this screen is shown with param-

eters in the case of a Combi.

2

3

1

Display the current action

1 Device search.

 Initialisation of the hardware and software.

Summary of Contents for Diagnose Tool

Page 1: ...lled in the heater 11 Export control unit separately 12 Mover 12 Control unit installed in the vehicle 12 Export control unit separately 12 Operation instructions software Intended use 13 User interfa...

Page 2: ...gnose Tool is connected the software needs to be installed on the computer Connect the Diagnose Tool to the computer I n t e r f a c e 1 2 D ia g n o s e T o o l U S B 1 2 V Operating voltage The inte...

Page 3: ...mbi adapter cable Connection to Combi 4 E Combi 6 E Combi D X1 Interface Diagnose Tool Combi 1 2 X1 Interface Diagnose Tool Combi 1 2 X1 Coupling RJ12 for cable extension Export error memory Start the...

Page 4: ...Simulate the connection of the safety socket with a bridge W1 Connect the Diagnose Tool to the Mover adapter cable W2 W1 W2 12 V 1 2 Interface Diagnose Tool SET 01 belu 2010 Export error memory Start...

Page 5: ...rogram Prerequisites for operation Device from index Combi 4 E Combi 6 E 4 12A 6 12A 4 11 6 11 4 12 6 12 4 13 6 13 Combi D 6 06 6 07 4 01 Mover all Mover S from 01 2008 Start program The Live Display...

Page 6: ...nd in the file system with Save error list 1 1 Click the dialogue Tools and select Reset errors The error memory in the device is reset deleted End program 1 1 Open the menu File and leave the program...

Page 7: ...2 Click the field ULMotor to change the parameters of the D C motor End program 1 1 Open the menu File and leave the program by pressing End Disconnect the diag nosis cable from the test object Switch...

Page 8: ...nde 19 Mover 19 Commande install e dans le v hicule 19 Consulter s par ment la commande 19 Mode d emploi logiciel Utilisation 20 Interface utilisateur 20 R gler la langue 20 Programme Diagnose Tool D...

Reviews: