Important notice 

 

Before calling a service technician please check carefully the 

operating instructions, warranty terms and conditions. If the 
product fails for any of the reasons detailed therein, or is faulty 
due to abuse, misuse or improper installation, then a service fee 
shall be charged to the purchaser.  

If you have any queries regarding the interpretation of the warranty 

you should contact Dometic Pty Ltd.  

Whilst this book represents service outlets at the time of printing, 

changes occur from time to time. Should you have any queries or 
wish to locate your nearest authorised service agent please contact 
Dometic Pty Ltd.  

Warranty does not cover 

 Any 

heater which has been:   

(a)

 

Subject to misuse, neglect, accident or alteration by any 

person.  

(b)

 

Damaged or destroyed by fire, flood, act of God or other 

inevitable accident.  

 

Fair wear and tear.   

 

Damage from foreign substances such as dirt or liquid.   

 

Travelling expenses or call out fee to and from authorised  service 
agents premises.  

 

Accommodation or Site Expenses.  

 

Cleaning of the system or cleaning and adjustment of the  gas 
system. This is considered to be a part of normal product 
maintenance. 

 

Non operation of the heater or resultant damage to the  unit 
where the heater has been operated in an out of level situation. 

 

Freight cost of the appliance or parts, to or from, point of  service 
or transit damage.  

 

Dometic / Truma are not responsible for resultant loss or  damage 
sustained by the purchaser.  

 

Non operation of the appliance or resultant damage to the  unit 
where the appliance has not been installed, ventilated, flued or 
operated in accordance with the manufacturers instructions.  

Apart from any warranties implied by the Trade Practices Act 1974 

or any relevant State legislation all other warranties express or 
implied whether arising by virtue of statute or otherwise are hereby 
excluded.  

Installation instructions 

Read the installation instructions carefully prior 
to starting work and observe the instructions! 

Non-compliance  with  installation  instructions 
or  incorrect  installation  can  result  in 

endangerment 

 

of persons and property.

 

This appliance shall be installed in accordance with the 

manufacturer’s installation instructions, local gas fitting regulations, 

municipal building codes, electrical wiring regulations. AS/NZS 5601 

“Gas installations”, and any other statutory regulations.

 

 Please pay attention to the ESD regulations!  

Intended use 

The Truma Combi 2 E / 4 E CP plus (Australia) liquid gas heater is a 

warm-air heater with integrated hot water boiler (10 litre capacity). 

The heater comes with additional electric heating elements, for 

operation with a mains voltage of 240 V ~. 

This unit was designed for installation in motor homes and caravans. 

The equipment must not be installed in buses or vehicles for 
transporting hazardous goods (vehicle classes M2 and M3). If the 
equipment is installed in special vehicles, the applicable regulations 
must be followed. 

Vehicules for hazardous materials

 

Combustion heaters for gaseous fuel are not permittet. 

Approval 

Declaration of conformity

 

The heater Combi 2 E / 4 E CP plus (Australia) is approved according 

AS 4552, AS 4556, AS/NZS 60335.2.21+A1-A3, AS/ NZS 
60335.2.30+A1, AS/NZS 60335.1+A1 and fulfills these standards: 

The heater complies with the electromagnetic compatibility for 

vehicles UN ECE R10. 

SAI Global Certification Number

 

GAS40016 

The year when the equipment was first taken into operation must 

be indicated with a check on the type plate.

 

Accessories

 

Summary of Contents for Combi 2E CP plus

Page 1: ...Combi 2 E 4 E CP plus Australia Operating instructions Page 2 Installation instructions Page 9 To be kept in the vehicle...

Page 2: ...ion 5 Gas connection with pressure test point not shown 6 Hot air outlets 7 Recirculated air intake 8 Waste gas discharge 9 Combustion air infeed 10 Electronic control unit 11 Water container 10 litre...

Page 3: ...unit gas mode only LPG for autonomous use electrical mode only 240 V for stationary use on camp sites or gas and electrical mode mixed mode Only possible in heating and hot water mode Heating and hot...

Page 4: ...essure control systems DuoControl CS for dual cylinder gas systems At temperatures of around 0 C or less the gas pressure regulator and the changeover valve should be operated using the EisEx regulato...

Page 5: ...er that has frozen The boiler can be thawed out again by briefly starting it up max 2 minutes Frozen lines can be thawed out by heating up the interior If connected to a central water supply rural or...

Page 6: ...switch If the 12 V power supply is interrupted during operation or during the after run period for example the temperatures within the unit could activate the overheating protection Fig 6 To reset th...

Page 7: ...Dimensions Fig 7 The right to effect technical modifications is reserved Truma warranty policy Truma CP plus The warranty is given by Dometic Pty Ltd Building 3B Digital control panel Truma CP plus pa...

Page 8: ...s Apart from any warranties implied by the Trade Practices Act 1974 or any relevant State legislation all other warranties express or implied whether arising by virtue of statute or otherwise are here...

Page 9: ...on with the original Fig 9 In order to heat the vehicle evenly throughout the heater must be installed in a location in the vehicle that is as central as possible in a wardrobe stowage compartment or...

Page 10: ...e heating device assembly instructions are enclosed with the delivery Installing the wall cowl Permissible duct lengths The length specific ations refer to the combusti on air intake duct Ducts with a...

Page 11: ...et of the unit in confined spaces we recommend the use of the BGC 90 elbow part no 34091 01 This elbow makes it possible to connect a R warm air duct with a diameter of 65 mm or a VR warm air duct wit...

Page 12: ...s 27 28 and safety drain valve 24 have a 12 mm rigid piping connection e g John Guest System For connecting to rigid pipes with other diameters appropiate adapters not included in scope of delivery mu...

Page 13: ...e regulation we recommend that the room temperature sensor be fitted above the entrance door Fig 26 Please ensure that the room temperature sensor is always attached to a vertical wall There may be no...

Page 14: ...from Truma for the different applications Please ask your dealer Other chargers may be used only with a 12 V battery as a buffer Room temperature sensor Attach plug of connecting cable to connection 4...

Page 15: ...Dometic Service C entre if problems are encountered in other countries the relevant service partners should be contacted www truma com Having the e quipment model and the serial number ready see type...

Page 16: ...Road Clayton Victoria 3168 Australia Service Australia Telephone 61 0 3 92 39 10 50 Facsimile 61 0 3 92 39 10 99 Dometic New Zealand Ltd Post Box 12011 1642 Penrose Auckland New Zealand Service New Z...

Reviews: