background image

2

EN

Aventa compact

Safety instructions

Only competent and trained persons 
(experts) may install, repair or perform 

the function check on the  Truma product in 
accordance with the installation and operat-
ing instructions and the currently accepted 
technical regulations. Experts are persons 
who, based on their specialist instruction and 
training, their knowledge and experience with 
 Truma products and the relevant standards, 
can carry out the necessary work properly and 
identify potential hazards.

The appliance must be installed in accordance 
with the national installation regulations.

This appliance may be used by children from 
8 years old and by persons with reduced phys-
ical, sensory or mental capabilities or with a 
lack of experience and knowledge only if they 
are supervised or have been instructed in the 
safe use of the appliance and understand the 
resulting risks.

Children must not be allowed to play with the 
appliance.

To avoid transportation damage, the appliance 
may only be dispatched if the  Truma Service 
Centre has been consulted beforehand.

When transporting on trailers with lowered 
drawbars, the openings on the rear side of the 
air conditioning system must be taped up in 
order to prevent water from entering.

The power supply must be disconnected 
from the mains (all poles) before opening the 
housing.

The appliance fuses and connection cables 
must only be replaced by experts.

The 230 V, T 5 A H (slow) appliance fuse can 
be found on the electronic control unit in the 
appliance and must always be replaced with 
an identical fuse.

Only original  Truma parts, spare parts and 
accessories may be used.

Symbols used

The appliance must only be installed and repaired  

by an expert.

Symbol indicates possible hazards.

Note containing information and tips.

The appliance is not accessible to the general public

You can also download the installation and operating 

instructions from our web site. Use the following link  

for the respective instructions:  

https://www.truma.com/int/en/service/downloads.html

Table of contents

Symbols used  ........................................................................  2

Safety instructions

  ............................................................  2

Notes on using air conditioning systems

  ......................  3

Operating instructions

Remote control  ......................................................................  4

Start-up  .................................................................................  5

Switching on  .........................................................................  5

Mode  .....................................................................................  5

Fan  .........................................................................................  5

Sleep function  .......................................................................  5

Switching off  .........................................................................  5

Time  .......................................................................................  5

Timer ON / OFF  .....................................................................  5

* Ambient lighting  .................................................................  5

Reset  .....................................................................................  5

Resend  ..................................................................................  5

Setup  .....................................................................................  6

IR receiver and manual on / off  .............................................  6

IR receiver / function display  .................................................  6

Red LED illuminated  ..............................................................  6

Air distribution  .......................................................................  6

IR remote control battery change  .........................................  6

Disposal

  ...............................................................................  6

Maintenance

  .......................................................................  6

Disposal

  ...............................................................................  6

Accessories

  .........................................................................  7

Troubleshooting

  .................................................................  7

Technical data

 .....................................................................  8

Installation dimensions (in mm)  ............................................  8

Clearance around the air conditioning system  .....................  8

Air inlets / outlets  ..................................................................  8

Condensation traps  ...............................................................  9

Manufacturer’s Warranty 

(European Union)

 ................................................................  9

Summary of Contents for Aventa compact

Page 1: ...EN Operating instructions To be kept in the vehicle Aventa compact Seite 2 Page 95...

Page 2: ...ower supply must be disconnected from the mains all poles before opening the housing The appliance fuses and connection cables must only be replaced by experts The 230 V T 5 A H slow appliance fuse ca...

Page 3: ...vehicle is being cleaned it must be ensured that no water gets into the appliance when spraying with a high pressure cleaner for example do not spray directly into the openings of the appliance Hot cl...

Page 4: ...matic Circulated air Temperatureselectionbuttons 16 31 C In 1 C steps On Off switch Reset Resets the remote control to the factory settings Fan level low medium high Resend Retransmit data Time select...

Page 5: ...ly depending on the room temperature In circulated air mode the interior air is recirculated and cleaned by the filters panels No LED s illuminate in the IR receiver Fan Select the required fan level...

Page 6: ...N 2400 1 5 V The battery compartment is on the back of the remote control When inserting new batteries make sure the positive negative terminals are con nected correctly Empty used batteries can leak...

Page 7: ...rop at 230 V power supply check 230 V power supply If these actions do not remedy the problem please con tact Truma Service Accessories Aventa air filter kit 2 pcs for air distributor not for air dist...

Page 8: ...T Figure 11 a air distributor small Air inlets outlets Figure 12 Technical data Determined on the basis of EN 14511 or Truma test conditions Power supply 230 V 240 V 50 Hz Power consumption Cooling 2...

Page 9: ...ingly and any repair and transport expenses shall then be the Consumer s liability We ask you not to send in an ap pliance without prior arrangement Condensation traps The condensation is led away via...

Page 10: ...type d appareil et le num ro de s rie voir plaque signal tique IT In caso di guasti rivolgersi al centro di assistenza Truma o a un nostro partner di assistenza autorizzato consultare il sito www trum...