Truma AquaGo basic Operating Instructions Manual Download Page 1

Professional decalcification kit for Truma AquaGo

®

Table of contents

Intended use

  ..........................................................................   3

Functional description

  ..........................................................   3

Scope of delivery

  ...................................................................   3

Safety instructions

  ................................................................   4

Operating instructions

  ..........................................................   7

Decalcification frequency  .........................................................   7
Preparing for decalcification  ....................................................   8
Connecting the circulation pump  .............................................   8
Carrying out the decalcification process   ...............................   10
Cleaning the circulation pump   ..............................................   10
Flushing the water system  .....................................................   11
Stopping decalcification  .........................................................   11

Accessories

  ..........................................................................   11

Technical data, pump

  .........................................................   11

Troubleshooting

  ..................................................................   12

MANUFACTURER LIMITED WARRANTY

  ........................   13

Summary of Contents for AquaGo basic

Page 1: ...s 4 Operating instructions 7 Decalcification frequency 7 Preparing for decalcification 8 Connecting the circulation pump 8 Carrying out the decalcification process 10 Cleaning the circulation pump 10...

Page 2: ...2 Legend 1 Easy Drain Lever 2 Outlet hose 3 Inlet hose 4 Socket 12 pin 5 Plug 6 POWER switch 7 Control panel 8 Connector cable circulation pump Circulation adapter Figure 2 Overview Figure 1...

Page 3: ...ication kit for AquaGo pumps a decalcification solution through the AquaGo instant water heater with the aid of a circulation pump This dissolves and flushes out calcium residues Scope of delivery Ser...

Page 4: ...erate injury is used to address practices not related to physical injury Other important information or tips Installation and service must be performed by an expert Improper installation altera tion s...

Page 5: ...Easy Drain Lever and water inlet filter or latch The use of non original AquaGo profes sional decalcification e g vinegar for de calcification can cause chemical reactions and produce hazardous subst...

Page 6: ...elid open and rinse with running water for 10 15 min Remove contact lenses if present and easy to do Continue rinsing Consult an eye specialist If you swallow the decalcification agent immediately rin...

Page 7: ...r the AquaGo instant water heater Decalcification frequency Lime scale occurs especially as a result of pre cipitation from hard water The AquaGo must be decalcified regularly depending on water hardn...

Page 8: ...he POWER switch 6 Open the hot water faucet and wait until cold water comes Leave the hot water faucet open in order to depressurize and vent the water system Interrupt the water supply Wait until no...

Page 9: ...fore inserting the circulation adapter 9 check that the O rings are in place and intact see Figure 2 page 2 Insert the circulation adapter 9 and close the Easy Drain Lever 1 see Figure 5 Figure 5 Plac...

Page 10: ...for 2 hours un der supervision Figure 7 Cleaning the circulation pump Remove the socket 4 from the plug 5 Dispose of the remaining decalcification product in accordance with the statutory regulations...

Page 11: ...and switch it on at the POWER switch 6 Close the access door of the AquaGo See Closing the access door in the operat ing instructions for the AquaGo instant water heater Decalcification is finished S...

Page 12: ...insufficient power supply Check and or establish a power supply Circulation pump defective Check and or replace circulation pump Water leaking at circulation adapter O ring dirty Clean O ring and corr...

Page 13: ...ctions provided and in compliance with applicable codes During the warranty period TRUMA will repair or replace at its own discretion and costs the defective Product or parts or components of such Pro...

Page 14: ...service center in the United States Truma Corp Service Center 825 East Jackson Blvd Elkhart IN 46516 toll free 855 558 7862 fax 574 538 2426 service trumacorp com www truma net The purchaser shall pr...

Page 15: ...or directly related to the causes of action asserted Unless prohibited under applicable state law in no event will TRUMA its agents subcontrac tors affiliates suppliers and employees be li able for a...

Page 16: ...e contact the Truma Service Center at 855 558 7862 or one of our autho rized service partners For details see www truma net Please have the model number and serial number on water heater s type plate...

Reviews: