background image

Chef Base Series

www.truemfg.com

TEC_TM_159 | REV. A | EN

07/6/2022 

Page 8 of 19

Installation (cont.)

Leveling

Proper leveling of your TRUE cooler is critical to operating success 
(for non-mobile models). Leveling impacts effective condensate 
removal and door operation.

Procedure

Level the unit front-to-back and side-to-side.

1. 

Position the level on the inside floor of the unit near the doors 
(the level should be parallel to cabinet front). Level the cabinet.

2. 

Position the level at the inside rear of cabinet (again, the level 
should be placed parallel to cabinet back). Level the cabinet.

3. 

Perform procedures similar to steps 1 and 2 by placing the 
level on inside floor (left and right side, parallel to the depth of 
the cooler). Level the cabinet.

NOTE: If the cabinet has a center leveling screw, castor, or leg, 

make sure it is adjusted properly so it makes full contact with 

the floor after the cabinet has been leveled.

Sealing the Cabinet to the Floor

Asphalt floors are susceptible to chemical attack. A layer of tape 
may be placed on the floor prior to applying the sealant to protect 
the floor.

Procedure

1. 

Position the cabinet, allowing 3" (73 mm) between the wall 
and the rear of the cabinet to ensure proper ventilation.

2. 

Level the cabinet. The cabinet should be level side-to-side 
and front-to-back. To check that the cabinet is level, place a 
carpenter's level on the interior cabinet floor in four places:

a. 

Position the level on the inside floor of the cabinet, near 

the doors (the level should be placed parallel to the cabinet 
front). Level the cabinet.

b. 

Position the level at the inside rear of the cabinet (the level 

should be placed parallel to the cabinet back). Level the 
cabinet.

c. 

Perform procedures similar to a and b by placing the level 

on the left and right inside floor (level should be parallel to 
the cabinet sides). Level the cabinet.

3. 

Draw an outline of the cooler base on the floor.

4. 

Raise and block the front side of the cabinet.

5. 

Apply a bead of NSF-approved sealant (see list below) to the 
floor, 1/2" (13 mm) inside the front part of the outline drawn in 
step 4. The bead of sealant must be heavy enough to seal the 
entire cabinet surface when the cabinet is lowered on top of 
the sealant.

6. 

Raise and block the rear of the cabinet.

7. 

Apply sealant to the floor on the other three sides, as outlined 
in step 5.

8. 

Examine the the cabinet to ensure that it is sealed to the floor 
around the entire perimeter.

NSF-Approved Sealants

•  3M #ECU800 Caulk
•  3M #ECU2185 Caulk
•  3M #ECU1055 Bead
•  3M #ECU1202 Bead
•  Armstrong Cork – Rubber Caulk
•  Products Research Co. #5000 Rubber Caulk
•  G.E. Silicone Sealer
•  Dow Corning Silicone Sealer

 A

 B

C

Fig. 4. 

Install castor shims in pairs.

Snug Fit

Here

Castor

Mounting

Plate

Castor

Leveling Shims

Leveling Shims

Side View

Left

Shim in

Position

Top View

Summary of Contents for TRCB Series

Page 1: ...55 878 9277 Warranty Fax 1 636 980 8510 Warranty Email WarrantyInquiries TrueMfg com Technical Phone 1 855 372 1368 Technical Email Service TrueMfg com 7 00am 6 00pm CST Monday Friday 8 00am 12 00pm Saturday UK Ireland Middle East Africa India Phone 44 0 800 783 2049 Service EMEA TrueMfg com 8 30am 5 00pm M F European Union Commonwealth of Independent States Phone 49 0 7622 6883 0 Service EMEA Tru...

Page 2: ... 7 Leveling Legs Castors 7 Leveling 8 Sealing the Cabinet to the Floor 8 Electrical Safety 9 Cabinet Setup Drawer Removal and Installation 10 Cabinet Operation Startup 12 Temperature Control Location 12 Sequence of Operation 13 Maintenance Care and Cleaning Condenser Coil Cleaning 14 Stainless Steel Care Cleaning 16 Cabinet Adjustments Servicing Component Replacement Sevicing Replacing Components ...

Page 3: ... as aerosol cans with a flammable propellant in this appliance Keep fingers out of the pinch point areas clearances between the doors and cabinet are necessarily small be careful closing doors when children are in the area DO NOT use electrical appliances inside the food storage compartments of the units unless the appliances are of the type recommended by the manufacturer NOTE All servicing must ...

Page 4: ...ratures shall not be less than 60 F 15 5 C and no greater than 104 F 40 C Appliance is not suitable for outdoor use Appliance is not suitable for an area where a pressure washer or hose may be used Ensure the location will provide adequate clearances and sufficient airflow for the cabinet Ensure the power supply for the cabinet matches the cabinet specification sheet or cabinet data plate and is w...

Page 5: ...2 10 10 8 8 8 8 6 6 6 18 14 12 10 10 8 8 8 8 8 8 8 5 20 14 12 10 10 8 8 8 6 6 6 5 5 25 12 10 10 8 8 6 6 6 6 5 4 4 30 12 10 8 8 6 6 6 6 5 4 4 3 35 10 10 8 6 6 6 5 5 4 4 3 2 40 10 8 8 6 6 5 5 4 4 3 2 2 45 10 8 6 6 6 5 4 4 3 3 2 1 50 10 8 6 6 5 4 4 3 3 2 1 1 230 Volts Distance In Feet To Center of Load AMPS 20 30 40 50 60 70 80 90 100 120 140 160 5 14 14 14 14 14 14 14 14 14 14 14 14 6 14 14 14 14 14...

Page 6: ...pliance b Carefully lay the unit on its back c With an adjustable wrench remove all shipping bolts securing the wood skid to the bottom of the appliance See fig 2 4 If leveling legs or castors will not be used carefully lift the appliance upright and position the unit in its final installation location If leveling legs or castors will be used proceed to leveling leg or castor installation instruct...

Page 7: ...n adjustable wrench adjust the bottom stem of the leveling leg as needed to level the unit See fig 2 NOTE DO NOT lift the unit by the countertops doors drawers or grills NOTE Be sure to leave the unit upright twice the time it was laying down up to 4 hours before restoring power If this time exceeds 4 hours let the unit stand upright for 24 hours before powering the unit Castor Installation 1 Loca...

Page 8: ... to back To check that the cabinet is level place a carpenter s level on the interior cabinet floor in four places a Position the level on the inside floor of the cabinet near the doors the level should be placed parallel to the cabinet front Level the cabinet b Position the level at the inside rear of the cabinet the level should be placed parallel to the cabinet back Level the cabinet c Perform ...

Page 9: ... cord that shows cracks or abrasion damage along its length or at either end If the supply power cord is damaged it should be replaced with original equipment manufacturer OEM components To avoid hazard this should be done by a licensed service provider Cabinet Wiring Diagram The cabinet s wiring diagram is in the exterior servicing compartment space of the cabinet A copy of the wiring diagram may...

Page 10: ...drawer rotate the roller clips upward See fig 3 4 Lift the drawer from the channel slot Installation 1 With the roller clips in the up position see fig 3 lower the drawer s rear rollers into the channel slots 2 Push the drawer into position 3 Rotate the roller clips to the down position See figs 1 and 2 Fig 1 Roller clip location Fig 2 Roller clip in down position Fig 3 Rotate the roller clip upwa...

Page 11: ...wer Installation 1 With the plastic drawer retainer raised align the drawer with the slide and push the drawer into position See figs 2b and 3 2 Align the drawer with the drawer slide and push the drawer into position 3 Press the plastic drawer retainer down and towards the back of the cabinet See fig 1 4 Verify correct drawer operation Fig 1 Drawer retainer location Retainer is engaged Fig 2a Pus...

Page 12: ...onnected or shut off wait 5 minutes before restarting RECOMMENDATION Before loading product run your TRUE unit empty for 24 hours to verify proper operation Remember our factory warranty DOES NOT cover product loss Electronic Temperature Control with Digital Display On the front of grill Mechanical Temperature Control Inside top ceiling or right wall Temperature Control Light Switch Location The l...

Page 13: ... control display may reflect the refrigeration cycle swings of up and down temperatures NOT product temperature The most accurate method to determine a cabinet s operation is to verify the product temperature Refrigerators with mechanical temperature controls will defrost during every compressor off cycle Freezers with mechanical temperature controls will defrost by time initiation as determined b...

Page 14: ...efore proceeding DO NOT clean appliance with a pressure washer or hose CAUTION Risk of eye injury Eye protection is recommended CAUTION Coil fins are sharp Gloves are recommended Required Tools Required tools include but may not be limited to the following Procedure 1 Disconnect power to unit 2 Remove the front louvered grill from the cabinet See fig 1 3 With a stiff bristle brush carefully clean ...

Page 15: ...aning cont Fig 3 Verify all blockages have been removed Fig 4 Condenser base bolt locations Fig 1 Front louver grill screw locations Fig 2 Never brush across coil fins Fig 6 Carefully slide the condensing unit back into position and reinstall the bolts Fig 5 Carefully slide the condensing unit out ...

Page 16: ...sement Omission of proprietary cleansers from this list does not imply inadequacy 8 Tips to Help Prevent Rust on Stainless Steel Maintain the Cleanliness of Your Equipment Avoid build up of hard stains by cleaning frequently Use cleaners at the recommended strength alkaline chlorinated or non chloride Use the Correct Cleaning Tools Use non abrasive tools when cleaning your stainless steel products...

Page 17: ... Have a licensed service provider service your unit to minimize the risk of possible ignition due to incorrect parts or improper service and to ensure the operator s health and safety Unplug the refrigerator freezer before cleaning or making any repairs Setting temperature controls to the 0 position or powering off an electronic control may not remove power from all components e g light circuits p...

Page 18: ...directly through TRUE All claims should include model number of the unit the serial number of the cabinet proof of purchase date of installation and all pertinent information supporting the existence of the alleged defect In case of warranty compressor a picture of the compressor model tag must be returned to TRUE along with above listed information For warranty claim information visit www truemfg...

Page 19: ...TEC_TM_159 REV A EN 07 6 2022 Page 19 of 19 www truemfg com EA AL_975534_07 2022 ...