• Do not place in direct sunlight.
• No HVAC supply or return air vents pushing air into or pulling
air out of the cabinet.
• No ceiling fans.
• No doorways.
• Make sure cabinet is level from front-to-back and side-to-side.
NOTE:
Check for correct clearance in back of and above the
cabinet. A 3" (77 mm) clearance is required at the rear of the
cabinet and 8" (204 mm) clearance above the cabinet.
• Maximum ambient conditions 75°F (24°C) or as indicated on
the serial label, and 55% relative humidity.
• Place cabinet in an area that will not have any air drafts.
• Excessive airflow around cabinet can effect interior cabinet
airflow (air-curtain).
Recommended Operating Conditions
Installation (cont.)
*
Or as indicated on the serial label.
3 inches
77 mm
8 inches / 204 mm
AIR FLO
W
≤ 75ºF
≤ 23ºC
≤ 55%