MAINTENANCE, CARE & CLEANING
MAINTENANCE, CARE & CLEANING
MAINTENANCE, CARE & CLEANING
CLEANING THE CONDENSER COIL
REQUIRED TOOLS
• Phillips Screwdriver
• Stiff Bristle Brush
• Adjustable Wrench
___________ STEP 1
___________
Disconnect power to unit.
___________ STEP 2
___________
DOUBLE-DUTY MODELS:
Take off front lower grill assembly by
removing four (4) screws in corners.
SINGLE DUTY MODELS:
Take off front lower grill assembly by
removing two (2) bottom screws.
If necessary, loosen screws holding
the top pivot pins. Swing grill up and
remove frame hooks from pivot pins
at top of louver.
___________ STEP 3
___________
Remove bolts anchoring compressor
assembly to frame rails and carefully
slide out. (tube connections are flexi-
ble)
___________ STEP 4
___________
Clean off accumulated dirt from con-
densing coil with a stiff bristle brush.
___________ STEP 5
___________
Lift cardboard cover above fan at
plastic plugs and carefully clean con-
denser coil and fan blades.
___________ STEP 6
___________
After brushing condenser coil vacuum
dirt from coil, and interior floor.
___________ STEP 7
___________
Replace cardboard cover. Carefully
slide compressor assembly back into
position and replace bolts.
___________ STEP 8
___________
Reinstall louver assembly onto unit,
tighten all screws.
___________ STEP 9
___________
Connect unit to power and check to
see if condensing unit is running.
Single Duty (TSID) Models