8
TRUE
TAC-27K / TAC-27K-HC-LD: AIR CURTAIN
www
.
truemfg
.
com
STARTUP
A. The compressor is ready to operate. Plug in the cooler.
PLEASE REVIEW THE FOLLOWING CAUTIONS
WHEN THE OPTIONAL HEATED PAN IS USED.
CAUTION:
This unit has two power supply cords. Unplug both
cords before moving or servicing this appliance.
CAUTION:
This unit has two power supply cords. Connect
each plug to a receptacle that is connected to an
individual branch circuit.
CAUTION:
This unit has more than one disconnect switch (plug).
B. Temperature controls are factory-set to give refrigerators an
approxiate temperature of 35°F (1.6ºC). Allow unit to function
several hours, completely cooling cabinet before changing the
control setting.
Temperature Control Location and Settings.
• Temperature control type will vary upon model and age of
cabinet.
• Mechanical control or electronic control without display:
- Inside cabinet
- Behind cabinet
- Behind front or rear access grill
• Electronic control with display:
- In countertop
- In top louvered panel
- In or behind bottom louvered grill
See website for adjustments, sequence of operation, and more
information.
C. Excessive tampering with the control could lead to service
difficulties. Should it ever become necessary to replace
temperature control, be sure it is ordered from your TRUE
dealer or recommended service agent.
D. Good air flow in your TRUE unit is critical. Be careful to
load product so that it neither presses against the back wall,
nor comes within four inches of the evaporator housing.
Refrigerated air off the coil must circulate down the back wall.
NOTE:
If the unit is disconnected or shut off, wait five minutes
before starting again.
RECOMMENDATION
- Before loading product we recommend
you run your TRUE unit empty for two to three days. This allows
you to be sure electrical wiring and installation are correct and no
shipping damage has occurred. Remember, our factory warranty does
not cover product loss!
LIGHT SWITCH LOCATION:
The light switch is located
behind the interior light inside the cabinet. HC cabinet lights are
turned on/off through the LAE temperature control. See page 14.
OPERATION
ON Position