INSTALLATION OF CASTORS OR 

OPTIONAL LEGS

Important Safeguard for installation of leg/castor. Images 1-5 demon-
strate procedure.

SECURING CASTORS AND LEGS

To obtain maximum strength and stability of the unit, it is important 
that you make sure each castor is secure. Optional legs are hand-
tightened securely against the lower rail assembly see image 4-5.  The 
bearing race on the castor or the top edge of the leg must make firm 
contact with the rail.

LEVELING SHIMS

Four leveling shims have been provided for leveling castored units 
positioned on uneven floors. Shims must be positioned between rail 
end and bearing race.

A.   Turn the bearing race counter-clockwise until the cabinet is 

level. Level front to back and side to side. (diagonally)

B.  Install the desired number of shims, making sure the slot of the 

shim is in contact with the threaded stem of the castor. See 
image 2.

C.  If more than one shim is used, turn the slot at a 90° angle so 

they are not in line.

D.  Turn the bearing race clockwise to tighten and secure the 

castor by tightening the anchoring bolt with a 3/4 inch open-
end wrench or the tool provided.  See image 3.

CAUTION:  TO AVOID DAMAGE TO LOWER RAIL 
ASSEMBLY, SLOWLY RAISE UNIT TO UPRIGHT 
POSITION.

NOTE:  OPEN HOLES LOCATED ON THE CROSS 
MEMBERS OF THE FRAME RAIL SHOULD BE 
PLUGGED BEFORE UNIT IS IN USE. 

Rail End

Lower Rail

Assembly

Snug Fit

Here

Leveling Shim

Castor

Leg

Bearing

Race

Lower Rail Assembly

Snug Fit

Here

Rail End

Thread castor into the underside of 
cabinet frame rail.

1

For leveling, insert the shim between 
castor and frame rail.

2

Use the tool provided to tighten the 
castor into place.

3

Thread leg into cabinet bottom 
frame rail.

4

5

The end of the leg is adjustable for 
easy leveling.

Summary of Contents for GDIM

Page 1: ...ALLATION MANUAL INSTALLATION MANUAL gdim glass door ice merchandisers TABLE OF CONTENTS 975541 LM 6 15 SAFETY INFORMATION Safety Precautions 1 Proper Disposal Connecting Electricity Adapter Plugs 2 IN...

Page 2: ...tions must be followed CAUTION Risk of fire or explosion Dispose of properly in accordance with federal or local regulations Flammable refrigerant used CAUTION Risk of fire or explosion due to punctur...

Page 3: ...OUNDED The power cord from this appliance is equipped with a grounding plug which minimizes the possibility of electric shock hazard Have the wall outlet and circuit checked by a qualified electrician...

Page 4: ...ges 4 6 Do not throw the bracket or blocks away For future cabinet movement the bracket and blocks will need to be installed so the glass door does not receive any damage See image for bracket and shi...

Page 5: ...8 8 8 5 20 14 12 10 10 8 8 8 6 6 6 5 5 25 12 10 10 8 8 6 6 6 6 5 4 4 30 12 10 8 8 6 6 6 6 5 4 4 3 35 10 10 8 6 6 6 5 5 4 4 3 2 40 10 8 8 6 6 5 5 4 4 3 2 2 45 10 8 6 6 6 5 4 4 3 3 2 1 50 10 8 6 6 5 4...

Page 6: ...stall the desired number of shims making sure the slot of the shim is in contact with the threaded stem of the castor See image 2 C If more than one shim is used turn the slot at a 90 angle so they ar...

Page 7: ...f the cooler Level cabinet STEP 3 Draw an outline on the base on the floor STEP 4 Raise and block the front side of the cabinet STEP 5 Apply a bead of NSF Approved Sealant see list below to floor on h...

Page 8: ...Should it ever become necessary to replace temperature control be sure it is ordered from your TRUE dealer or recommended service agent D Good air flow in your TRUE unit is critical Be careful to loa...

Page 9: ...e evaporator coil is reached 3 The temperature control may cycle the compressor and evaporator fan s on and off together a The temperature control is sensing the air temperature b The temperature cont...

Page 10: ...making adjustment measure temperature during three cycles before adjusting again NOTE Only adjust the screw small flathead on the face of the control next to the cam See Figure 3 Follow the Altitude...

Page 11: ...which wire is on which spade terminal STEP 4 Pull out gently from cabinet NOTE Mechanical temperature controllers are affected when functioning at high altitude The cut in and cut out temperatures wil...

Page 12: ...truemfg com O 9 8 7 6 5 4 3 2 1 2 O 9 8 7 5 4 3 2 1 CUT OUT CUT IN COLDER BUL NO CHART CCW Adjustment based on 360 complete turn Height 2000 42 3000 78 4000 114 5000 150 6000 186 7000 222 8000 258 900...

Page 13: ...RATION FOR UNITS WITH MECHANICAL CONTROL RECOMMENDED DEFROST SETTINGS TRUE Manufacturing has factory set your defrost time clock to a recommended time and duration defrost scenario All refrigeration e...

Page 14: ...carefully slide out tube connections are flexible STEP 4 Clean off accumulated dirt from condensing coil with a stiff bristle brush STEP 5 Lift cardboard cover above fan at plastic plugs and carefully...

Page 15: ...pose the Condenser The Condenser looks like a group of vertical fins You need to be able to see through the condenser for the unit to function at maximum capacity Do not place filter material in front...

Page 16: ...STAINLESS STEEL 1 USING THE CORRECT CLEANING TOOLS Use non abrasive tools when cleaning your stainless steel products The stainless steel s passive layer will not be harmed by soft cloths and plastic...

Page 17: ...ulb 2 GENERAL MAINTENANCE LIGHT BULB REPLACEMENT IDL INTEGRATED DOOR LIGHTING WARNING When replacing a light bulb make sure power to the unit is either turned off or unplugged IDL INTEGRATED DOOR LIGH...

Page 18: ...vacuums must be achieved to insure low moisture levels in the system 500 microns or lower must be obtained All claims for labor or parts must be made directly throughTRUE All claims should include mo...

Reviews: