TRU Components 2436041 Operating Instructions Manual Download Page 4

Standards .........................IEEE802.3 10BASE-T

..........................................

IEEE802.3u 100Base-TX

..........................................

IEEE802.3x

Network media (cable) ......

10BASE-T: Category 3, 4, 5 UTP cable (≤ 100 m) 

..........................................

100BASE-TX: Category 5 UTP cable (≤ 100 m)

Industry standards ............

FCC CFR47 Part 15, EN55022/CISPR22, Class A 

EMS

.............................. ....

IEC61000-4-2 (ESD): ±8 kV (contact), ±12 kV (air)

..........................................

IEC61000-4-3 (RS): 10 V/m (80 MHz - 2 GHz)

..........................................

IEC61000-4-4 (EFT): Power port: ±2 kV; Data port: ±1 kV

..........................................

IEC61000-4-5 (Surge): Power port: ±1 kV/DM, ±2 kV/CM;

 

Data port: ±1 kV

..........................................

IEC61000-4-6 (CS): 3 V (10 kHz - 150 kHz); 10 V (150 kHz - 80 MHz)

..........................................

IEC61000-4-16 (Common mode conduction): 30 V (cont.), 300 V (1 s)

Dimensions (W x H x L) ....128 x 35 x 98 mm
Weight ..............................320 g
Ambient temperature 

during operation ................-40 °C to +75 °C
Ambient temperature 

during storage ...................-40 °C to +75 °C
Ambient humidity 

during operation ................

5% to 95% rel. humidity, non-condensing

12 Technical data

Item No. 2436042
Ports .................................5x RJ-45 auto-MDI / MDI-X 

Specifications

 ...................Bandwidth: 10 Gbit/s

..........................................

Buffer packet memory: 1.2Mbit

..........................................

Forwarding rate: 1488095 pps/port

..........................................

MAC address table: 2 K

Installation ........................DIN rail

Max. frame size

 ................

1522 bytes packet size

Flow control ......................Back pressure for half duplex

..........................................

IEEE 802.3x pause frame for full duplex

Housing ............................IP40 metal housing
LED status indicator .........Power:  Red

..........................................

Ethernet: Yellow 

Operating voltage .............12 - 52 V/DC (Redundant dual)
Power consumption ..........3 Watts
Surge protection ...............ESD (Ethernet): 8 KV/DC
..........................................Surge (power supply): 2 KV/DC
Standards .........................IEEE802.3 10BASE-T

..........................................IEEE802.3u 100Base-TX

..........................................IEEE802.3ab 1000Base-T

..........................................IEEE802.3x
Network media (cable) ......

10BASE-T: Category 3, 4, 5 UTP cable (≤ 100 m) 

..........................................

100BASE-TX: Category 5 UTP cable (≤ 100 m)

..........................................

1000BASE-TX: Category 6 or better UTP cable (≤ 100 m)

Industry standards ............

FCC CFR47 Part 15, EN55022/CISPR22, Class A 

EMS

.............................. ....

IEC61000-4-2 (ESD): ±8 kV (contact), ±12 kV (air)

..........................................

IEC61000-4-3 (RS): 10 V/m (80 MHz - 2 GHz)

..........................................

IEC61000-4-4 (EFT): Power port: ±2 kV; Data port: ±1 kV

..........................................

IEC61000-4-5 (Surge): Power port: ±1 kV/DM, ±2 kV/CM;

 

Data port: ±2 kV

..........................................

IEC61000-4-6 (CS): 3 V (10 kHz - 150 kHz); 10 V (150 kHz - 80 MHz)

..........................................

IEC61000-4-16 (Common mode conduction): 30 V (cont.), 300 V (1 s)

Dimensions (W x H x L) ....128 x 35 x 98 mm
Weight ..............................360 g
Ambient temperature 

during operation ................-40 °C to +75 °C
Ambient temperature 

during storage ...................-40 °C to +75 °C
Ambient humidity 

during operation ................

5% to 95% rel. humidity, non-condensing

7 LED status indicator

The LED indicators provide information about the operating status in real time.

LED

Status

Information

POWER

ON

Indicates that the switch is on.

OFF

No power supply

Link/Act

Yellow "on"

Connection is active

Yellow "flashing"

Indicates that the switch is actively sending or 

receiving data via this port.

Yellow "off"

No device is connected to the corresponding port.

8 FAQ

The power supply indicator (POWER) is off.
Check the power supply at terminals P1 and P2. 

Is the terminal strip (2)

 firmly inserted in the socket?

 

Is the power supply between 12 and 52 V/DC?

The Link/Act LED is off.
No data is being sent on the network. 

Is the network cable intact and plugged in at both ends?

 

No data is being transferred on the switch. Check that the network automatically receives IP 

addresses. The switch does not assign IP addresses.

9 Cleaning and care

 

This product does not require any maintenance. Never attempt to dismantle it. Disconnect 

the product from the mains supply before cleaning. Dust can easily be removed using a 

clean, soft brush and a vacuum cleaner. Do not use aggressive cleaning agents, as these 

can cause discolouration. To prevent scratch marks, do not press too strongly on the sur

-

face when cleaning.

10 Disposal

10.1 Product

This symbol must appear on any electrical and electronic equipment placed on the 

EU market. This symbol indicates that this device should not be disposed of as 

unsorted municipal waste at the end of its service life.
Owners of WEEE shall dispose of it separately from unsorted municipal waste. 

Spent batteries and accumulators, which are not enclosed by the WEEE, as well 

as lamps that can be removed from the WEEE in a non-destructive manner, must 

be removed by end users from the WEEE in a non-destructive manner before it is 

handed over to a collection point.

Distributors of electrical and electronic equipment are legally obliged to provide free take-back 

of waste. Conrad provides the following return options free of charge (more details on our 

website):

 

in our Conrad offices

 

at the Conrad collection points

 

at the collection points of public waste management authorities or the collection points set 

up by manufacturers or distributors within the meaning of the ElektroG

End users are responsible for deleting personal data from the WEEE to be disposed of.
It should be noted that different obligations about the return or recycling of WEEE may apply in 

countries outside of Germany

11 Technical data

Item no. 2436041
Ports .................................5x RJ-45 auto-MDI / MDI-X 

Specifications

 ...................Bandwidth: 2 Gbit/s

..........................................

Buffer packet memory: 1 Mbit

..........................................

Forwarding rate: 148809 pps/port

..........................................

MAC address table: 2 K

Installation ........................DIN rail

Max. frame size

 ................

1522 bytes packet size

Flow control ......................Back pressure for half duplex

..........................................

IEEE 802.3x pause frame for full duplex

Housing ............................IP40 metal housing
LED status indicator .........Power:  Red

..........................................

Ethernet: Yellow 

Operating voltage .............12 - 52 V/DC (Redundant dual)
Power consumption ..........3 Watts
Surge protection ...............ESD (Ethernet): 8 KV/DC

..........................................

Surge (power supply): 2 KV/DC

This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). 
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in 

electronic data processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. 

This publication represent the technical status at the time of printing.
Copyright 2022 by Conrad Electronic SE. 

  

*2436041_42_V3_0722_02_m_VTP_EN

Summary of Contents for 2436041

Page 1: ...er Switch unter widrigsten Bedingungen eingesetzt werden Die Sicherheitshinweise und alle anderen Informationen dieser Bedienungsanleitung sind unbedingt zu beachten Eine andere Verwendung als zuvor b...

Page 2: ...gesteckt Es findet keine Daten bertragung auf dem Switch statt Pr fen Sie ob das Netzwerk automa tisch IP Adressen erh lt Der Switch weist keine IP Adressen zu 9 Reinigung und Plege Das Produkt ist f...

Page 3: ...tions RJ45 The product can be mounted on a DIN rail The switch is designed for harsh industrial environments With a temperature range of 40 C to 75 C the switch can be used in the harshest of conditio...

Page 4: ...C The Link Act LED is off No data is being sent on the network Is the network cable intact and plugged in at both ends No data is being transferred on the switch Check that the network automatically r...

Page 5: ...une plage de temp rature comprise entre 40 C et 75 C le commutateur peut tre utilis dans les conditions les plus d favorables Les consignes de s curit et toutes les autres informations de ce mode d e...

Page 6: ...age et entretien Le produit ne n cessite aucune maintenance pri re de ne pas le d manteler D branchez le produit de la prise de courant avant tout nettoyage Vous pouvez tr s facilement liminer les pou...

Page 7: ...ng Met een temperatuurbereik van 40 C tot 75 C kan de switch onder de meest ongunstige omstandigheden worden gebruikt De veiligheidsaanwijzingen en alle andere informatie die in deze gebruiksaanwijzin...

Page 8: ...st geen IP adressen toe 9 Onderhoud en reiniging Het product is onderhoudsvrij demonteer het nooit Koppel het product los van de stroom voorziening voordat u het reinigt Stof kan gemakkelijk met een z...

Reviews: