TRU Components 1661882 Operating Instructions Manual Download Page 4

*) Specialist knowledge required for the installation:
In particular, the following expertise is required for installation:
•  the applicable “5 safety rules”: Switch off power; secure against switching back 

on; determine voltage-free status; earthing and short-circuiting; cover or fence off 

nearby live parts

•  Choose appropriate tools, meters and, if necessary, personal protective equipment
•  Evaluation of the measurement results
•  Selection of the electrical installation material to ensure the shutdown conditions
•  IP protection types
•  Installation of the electrical installation material
•  Type of mains supply network (TN system, IT system, TT system) and the con-

nection conditions that follow from them (classical earthing, protective earthing, 

required additional measures, etc.)

If you do not have the expertise required for the installation, do not install it 

yourself, but entrust the work to a qualified electrician. 

a) General information

•  The unauthorised conversion and/or modification of the product is not allowed for 

safety and approval reasons. 

•  Maintenance, adjustment or repair work may only be carried out by an expert/author-

ised service centre familiar with the hazards involved and the relevant regulations. 

•  The product is not a toy and should be kept out of the reach of children! There 

is danger of a life-threatening electric shock! Install the product out of the reach 

of children. 

•  Protect the product from extreme temperatures, direct sunlight, strong vibrations, 

high humidity, moisture, combustible gases, vapours and solvents.

•  Handle the product with care; it can be damaged by impacts, blows or falls even 

from a low height. 

•  Do not leave the packaging material lying around carelessly as it may be a danger 

to children.

•  On industrial sites, the accident prevention regulations of the association of the 

industrial workers‘ society for electrical equipment and utilities must be followed!

•  Consult a qualified technician, if you are not sure how to operate or how to safely 

connect the equipment.

•  Maintenance, adjustment and repair work should only be carried out by an expert 

or a specialist workshop.

•  If you have any questions that are not answered in these operating instructions, 

please contact our technical customer service or other technicians.

b) Connection

•  Item no. 1661882 and 1661883: 

The construction of the product corresponds to protection class II (double or rein-

forced insulation). However, an internal connector for the protective earth conduc-

tor is provided. The product may thus be used for with protection class II and with 

protection class I luminaires. A mains cable with protective earth conductor must 

be used for luminaires of protection class I. The protective earth conductor of the 

mains cable must be connected to the protective earth conductor of the connected 

luminaire. Failure to observe this poses a danger to life from electric shock!

•  Item no. 1661885 and 1661886: 

The construction of the dimmer corresponds to protection class II (double or rein-

forced insulation). Only a luminaire of protection class II can be connected to the 

dimmer. Do not connect luminaires to this dimmer that require a protective earth 

conductor! There is a risk of a life-threatening electric shock!

•  Make the connection only after ensuring the absence of any voltage/ current. 
•  Ensure that the insulation of the housing is neither damaged nor destroyed.
•  The mains socket to which the product is connected must be easily accessible.
•  Never overload the product. Note the maximum load capacity in the chapter “Tech-

nical data”.

•  Observe the minimum load capacity in the chapter “Technical data”. Malfunction-

ing may occur if the minimum load capacity is not reached. 

c) Operation

•  The product is not a toy. Devices operated on mains voltage should not be used by 

children. Therefore, be especially careful when children are around. 
Use the product where it is out of the reach of children. 

•  Do not use the product in rooms with adverse environmental conditions, where 

combustible gases, vapours or dust are or may be present! There is a danger of 

explosion!

•  Connecting to the mains voltage and operating the product is only permissible if 

the housing is closed.

•  Never use the product in a vehicle.
•  Install all cables in such a way that nobody may trip over them.
•  Handle the product with care; it can be damaged by impacts, blows or falls even 

from a low height.

•  Avoid the following unfavourable ambient conditions at the installation point or 

during transportation or storage:

 Operating instructions

Dimmer 

Item no. 1661882 (slide dimmer, white, 60 - 300 W) 
Item no. 1661883 (slide dimmer, black, 60 - 300 W)
Item no. 1661885 (rotary knop dimmers, black, 25 - 150 W)
Item no. 1661886 (rotary knop dimmers, white, 25 - 150 W)

Intended use

The dimmer is a retrofitting for luminaires already in service with incandescent or halogen 

lamps without ballast. This enables you to adjust the brightness of the luminaire infinitely. The 

dimmer is only suitable for connecting to the mains voltage (see chapter “Technical data”).
For safety and compliance reasons, the product must not be converted or modified in any way. 

If you use the product for other purposes than those described above, the product may be dam-

aged. Moreover, improper use involves risks such as short-circuits, fire, electric shocks, etc. 

Please read the operating instructions carefully and do not discard them. Please include these 

operating instructions when you pass the product on to a third party.
This product complies with the applicable national and European Regulations. All names of 

companies and products are the trademarks of the respective owners. All rights reserved.

Package contents

•  Dimmer
•  Operating instructions

Up-to-date operating instructions           

Download the latest operating instructions via the link www.conrad.com/downloads or scan the 

QR code. Follow the instructions on the website.

Explanation of symbols

  The lightning symbol inside a triangle is used when there is a potential risk of per-

sonal injury, such as electric shock.

  An exclamation mark in a triangle indicates important steps in these operating in-

structions which should be absolutely observed.

  The arrow symbol indicates specific tips and advice on operation.

  The product is designed according to protection Class II (reinforced or double insu-

lation, protective insulation).

   The product is only intended to be installed and used in dry indoor spaces; it must 

not get damp or wet.

  Observe the operating instructions.

Safety instructions

Please read the operating instructions carefully and pay particular attention 

to the safety instructions. We do not assume liability for any injuries/mate-

rial damages resulting from failure to observe the safety instructions and the 

information in these operating instructions regarding the proper use of the 

product. Furthermore, in such cases, the warranty/guarantee will be null and 

void.
Attention, important note!
Only persons with relevant electro-technical knowledge and experience 

should carry out the installation! *)
If it is not installed properly, you risk:
•  your own life
•  the life of the person using the electrical system.
If it is not installed properly, you risk severe damage to property, e.g., by fire.
There is a risk of you being held liable for personal injury and material damage. 
Contact an electrician!

Summary of Contents for 1661882

Page 1: ...ssen werden Es besteht Lebensgefahr durch einen elek trischen Schlag Der Anschluss darf nur im spannungs stromlosen Zustand vorgenommen wer den Es ist darauf zu achten dass die Isolierung des Geh uses...

Page 2: ...diese Bedienungsanleitung mit den Sicherheitshinweisen vollst ndig und aufmerksam durch Lassen Sie Montage und Anschluss im Zweifelsfall durch eine Fachkraft durchf hren Ein Anschluss darf nur im span...

Page 3: ...ie wie folgt vor um die Sicherung zu wechseln Trennen Sie den Dimmer von der Netzspannung ziehen Sie den Netzstecker vollst ndig aus der Netzsteckdose Beseitigen Sie die Ursache der berlast z B eine b...

Page 4: ...serve the minimum load capacity in the chapter Technical data Malfunction ing may occur if the minimum load capacity is not reached c Operation The product is not a toy Devices operated on mains volta...

Page 5: ...s I The protective earth conductor of the mains cable must be connected to the protective earth conductor of the connected luminaire Failure to observe this poses a danger to life from electric shock...

Page 6: ...se the housing again ensure the correct orientation of the slider or knob on the dimmer Then screw down the housing Connect the dimmer to the mains voltage and test whether the dimmer and the connecte...

Page 7: ...e variateur Les lampes qui exigent un conducteur de protection ne doivent pas tre raccord es ce variateur Il y a danger de mort par choc lectrique Le raccordement des c bles d alimentation secteur doi...

Page 8: ...e s curit En cas de doute confiez le montage et le raccordement un sp cialiste Le branchement doit tre effectu uniquement lorsque l appareil est hors tension circuit Sinon il y a danger de mort par ch...

Page 9: ...c dez comme suit pour changer le fusible D connectez d abord le variateur de la tension de secteur d branchez compl tement la fiche d alimentation de la prise de courant liminez la raison de la surcha...

Page 10: ...elektrische schok De aansluiting mag alleen gebeuren in een spannings stroomloze toestand Let erop dat de isolatie van de behuizing niet wordt beschadigd of verwijderd De contactdoos waarop het produc...

Page 11: ...el de inbouw en aansluiting door een vakman uitvoeren Aansluiting mag alleen in spannings stroomvrije toestand worden uitgevoerd An ders bestaat er levensgevaar door een elektrische schok De reeds aan...

Page 12: ...rk bij het vervangen van een zekering Koppel de dimmer los van de netspanning trek de stekker geheel uit de contactdoos Stel de oorzaak van de overbelasting vast b v Een overbelasting van de dimmer ma...