Connecting the EtherWind to an RS-232 Serial Device
Note: Skip this section if you are not using the EtherWind serial port.
The EtherWind has one standard PC-compatible 9-pin female D-connectors. The
serial port uses PC-compatible 9-pin male D-connectors. Note that the standard
off-the-shelf 9-pin female to 25-pin male PC cables will require a null modem in
order to connect to most printers or terminals. The pin-outs are as follows:
DB9
DTE
DCE
pin
Signal
Signal
pin
pin
1
Not used
Not used
-
-
2
Receive Data
Transmit Data
2
3
3
Transmit Data
Receive Data
3
2
4
DTR out
DSR in
6
20
5
Signal Ground
Signal Ground
7
7
6
DSR in
DTR out
20
6
7
RTS out
CTS in
5
4
8
CTS in
RTS out
4
5
9
Not used
Not used
-
-
Basically, the cable must connect input signals (e.g., Receive Data) on the TROY
EtherWind to the equivalent output signals (e.g., Transmit Data) on the device
and vice-versa.
The serial port can be set to operate in console mode to allow you to configure
and diagnose the EtherWind via a serial terminal (or PC with a terminal emula-
tion program). To enable the console mode manually, unplug the power supply
from the serial server, hold down the Test switch and simultaneously plug in the
power supply.
The port will remain in console mode until the unit is power off.
You may also nable console mode by connecting remotely to the EtherWind via
WebXAdmin, TELNET, NCP, or XConfig (refer to Chapter 3 for information on
how to use these utilities). With WebXAdmin, select
Configure
Port from the
main menu, click on serial port S1, select
Console Mode,
and click
Submit
.
With TELNET or XCONFIG, use the following command:
1-4
Summary of Contents for C7200n
Page 1: ...User s Guide 802 11b Print Server Part Number 40148 100 Revision 1 0 ...
Page 8: ...4 ...
Page 14: ...1 6 ...
Page 20: ...2 6 ...
Page 32: ...6 4 ...