Filter change, inserting filters

Before installation

Be sure to install the explosion-proof filter only
in a place that is suitable. This includes:

Specify the installation location as a haz-
ardous area according to directive
1999/92/EC

Make sure that the internal ATEX docu-
mentation according to directive
1999/92/EC and the operational safety
regulations are available

Unpack the filter outside of areas with poten-
tially explosive atmospheres.

Handle the filter with care to not damage
the filter medium.
Hold the filter only by the edges.

Check the filter for external damage and
completeness, 

Ä

 Chapter 3  ‘Supply

package, transport and storage’
on page 2

. Do not install a damaged or

incomplete filter.

Installation

Personnel:

Properly trained person

Protective equipment:

Industrial safety helmet

Light respiratory protection

Protective gloves

Before you start changing filters, switch off the ven-
tilation and air conditioning system; if necessary,
purge the system with fresh air beforehand.

1.

Remove the existing filter and the earth
cable.

2.

Then clean the system as required.

3.

Insert the new explosion-proof filter and
secure it.

Be sure to not damage the filter medium:

Handle the filter with care and only touch the
frame.

Fig. 1: Earth cable

4.

After you have inserted the filter, make an
electrical connection between the earth
cable with the terminal (1) and an earthed
system component. Make the connection in
such a way that it cannot come loose, but
can only be separated with a tool.

Filter change, inserting filters

 

PFG-Ex Explosion-proof pocket filter

3

Summary of Contents for PFG-E Series

Page 1: ...ment group 2014 34 EU II Equipment category 2014 34 EU 2 Hazardous areas 1999 92 EC Zones 1 2 21 22 Other procedural instructions and documents related to areas with potentially explosive atmos pheres as defined in directive 1999 92 EC as well as the industry specific guidelines for use handling maintenance and disposal of air filters for ventilation and air conditioning systems SWKI 2003 and VDI ...

Page 2: ... transport damage and complete ness Then put the product back into its packaging Supply package Filter PFG Ex Earth cable ATEX label Installation and maintenance manual Transport Do not remove the protective wrapping until just before installation Storage Please note Store the product only in its original packaging Protect the product from the effects of weather Protect the product from humidity d...

Page 3: ...aged or incomplete filter Installation Personnel Properly trained person Protective equipment Industrial safety helmet Light respiratory protection Protective gloves Before you start changing filters switch off the ven tilation and air conditioning system if necessary purge the system with fresh air beforehand 1 Remove the existing filter and the earth cable 2 Then clean the system as required 3 I...

Page 4: ...ion Make sure that the terminal connec tion cannot come loose Check the electrical resistance between the filter frame and the system component with an ohm meter The electrical resistance must not exceed 1 MΩ mega ohms 5 Finally affix the supplied ATEX sticker to the outside of the filter inspection access so that people can see it Filter change inserting filters PFG Ex Explosion proof pocket filt...

Page 5: ...erential pressure has been reached if this is more economic Disposal ENVIRONMENT Risk of harm to the environment due to the incor rect handling of hazardous materials and sub stances Filters and cleaning materials that have been contaminated with bacterial toxic or radioactive particles are considered hazardous waste and have to be disposed of by an authorised business in compliance with local reg...

Reviews: