submerged waste water pump TWP 4025 E / TWP 7025 E / TWP 11025 E

Hold onto the mains plug while pulling the power cable out
of the mains socket.

Protect the power supply cable against heat, oil and sharp
edges.

Only use splash-proof extension cables intended for
outdoor use whilst observing the device's power input.
Before using cable drums, always unroll the cable
completely. Check the cable for damage.

Before performing any work on the device, in case of leaks
in the water system, before taking work breaks or when
not in use, remove the mains plug from the mains socket.

General safety warnings – Personal safety

Never use the device with persons or animals in the water
or pumping medium or if they could access it. 

There is a

risk of electric shock!

Never insert any objects or limbs into the device.

This appliance is not a toy! Keep away from children and
animals. Do not leave the device unattended during
operation.

Device-specific safety warnings for submerged
pumps

Do not leave the device running unattended to ensure an
early detection of when the device runs dry or switches off
automatically. This would damage the device. Regularly
check the float for proper functioning.

Please bear in mind, that the device is not suitable for
continuous operation (e.g. for watercourses in garden
ponds). Check the device for proper functioning on a
regular basis.

Keep in mind, that lubricants are used within the device.
These might potentially cause damages or contaminations
if emitted. Do not use the device for drinking water or in
garden ponds with either a fish population or valuable
plants.

The device is not to be carried by holding it at the power
supply cable or hose. Do not fasten it there either.

Do not place any objects on the device – not even to
weight it down. The device will sink to the ground due to
its own weight.

After the set-up of the device, its mains plug must be
readily accessible during operation.

Wear sturdy shoes to protect yourself against electric
shock.

Before taking the device into operation, have the following
checked by an expert:

– earthing, neutral conductor and RCD must be

functioning properly and correspond to the national
regulations,

– electrical plug connections must be protected from

moisture.

Provide appropriate frost protection.

Intended use

The device 

TWP 4025 E

 / 

TWP 7025 E

 / 

TWP 11025 E

 is only

suited for draining, conveying and pumping over the following
media:

clear water and waste water

non-corrosive suds (e.g. leaking washing machine)

slightly chlorinated water

When doing so, the water must not contain any suspended
matter exceeding a maximum particle size of 25 mm.
The device is fully submersible (watertight encapsulation) and
can be immersed up to 5 m (

TWP 4025 E

) or 7 m (

TWP 7025 E

 /

TWP 11025 E

) into the conveyed medium.

The water temperature must not exceed 35 °C.
The device may temporarily be used for e.g.:

pumping out flooded basements

emptying tanks and containers

the water withdrawal from wells and shafts

Summary of Contents for TWP 11025 E

Page 1: ...TRT BA TWP4025E TWP7025E TWP11025E TC2018 62 002 EN TWP 4025 E TWP 7025 E TWP 11025 E EN OPERATING MANUAL SUBMERGED WASTE WATER PUMP...

Page 2: ...This symbol indicates that you must be aware of the dangers that can occur when working with the device Device may start up without warning This symbol indicates that the device may start up without...

Page 3: ...onto the mains plug while doing so When positioning the device observe the minimum distances from walls and other objects as well as the storage and operating conditions specified in the Technical dat...

Page 4: ...lubricants are used within the device These might potentially cause damages or contaminations if emitted Do not use the device for drinking water or in garden ponds with either a fish population or va...

Page 5: ...working with electric devices in damp areas have read and understood the operating manual especially the Safety chapter Residual risks Warning of electrical voltage Work on the electrical components m...

Page 6: ...ht can be finely adjusted within the specified range by means of a locking device see technical data The water temperature must not exceed 35 C Info The illustrations in this operating manual feature...

Page 7: ...difficulties Assembly and installation Scope of delivery 1 x Submerged waste water pump 1 x Reducer for inner diameters 25 mm and 32 mm as well as for 1 internal threads 1 x Elbow 1 x Nylon cord 12 m...

Page 8: ...t thread Slide an appropriate hose clamp onto the hose 4 Push the hose inner diameter 25 mm or 32 mm onto the reducer 7 all the way to the stop 5 Affix the hose by means of the hose clamp 6 When using...

Page 9: ...ake sure that the position of float switch 4 is adjusted in a way that it does not lie flat on the ground This could prevent the automatic switch off causing the device to run dry 1 If required lock t...

Page 10: ...E 2 Lower the device into the water at a slight angle to allow any remaining air to escape 3 If you want the device to be positioned on the ground ensure that the latter is even 4 Attach the nylon cor...

Page 11: ...nto the mains plug while pulling the power cable out of the mains socket 2 If necessary pull the device out by means of the nylon cord 3 Lock the float switch 4 in the following position 4 With the fl...

Page 12: ...er the water contains any suspended matter with a particle size of more than 25 mm which could clog up the device Check whether the used hose diameter is too small Check whether the hose line is kinke...

Page 13: ...d to be maintained or lubricated by the user Cleaning Clean the device with a soft damp and lint free cloth Protect electrical components from moisture Do not use any aggressive cleaning agents such a...

Page 14: ...V 240 V 50 Hz Max power consumption 400 W 750 W 1100 W Protection type IPX8 IPX8 IPX8 Minimum operating depth 90 mm 115 mm 115 mm Max water level after suction 35 mm 35 mm 35 mm Connection type CEE 7...

Page 15: ...cm 45 cm TWP 4025 E TWP 7025 E 9 m max 7 m max max 35 C 25 cm 50 cm TWP 7025 E TWP 11025 E 11 m max 7 m max max 35 18 cm 60 cm TWP 11025E Performance chart pump height feed rate TWP 4025 E 9 000 6 00...

Page 16: ...rical and electronic equipment in your vicinity The addresses can be obtained from your municipality or local administration For further return options provided by us please refer to our website www t...

Page 17: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...