Trotec TVE 100 Operating Manual Download Page 9

EN

9

360° turbo fan TVE 100

Automatic switch-off

ü

The device is switched on.

1. Press the 

Timer

 button (

18

) to activate the timer.

ð

The segment display (

19

) flashes and the LED 

h

 is

illuminated.

2. Turn the rotary switch (

8

) clockwise to increase the

number of hours of the timer.
Turn the rotary switch (

8

) counter-clockwise to reduce the

number of hours of the timer.

ð

If you set the fan stage at the same time you select
automatic switch-off, the fan stage and switch-off time
are shown alternately on the display.

Notes regarding automatic switch-off:

Manually switching the device off disables the automatic
switch-off function.

If you select 0 hours, the timer will be off.

Memory function

When switched on from standby, the device switches back to
the preset operating mode, except sleep mode.
Any activated timer will not be saved in the device.

Switching the display on or off

Please proceed as follows to switch the display (

19

) on or off:

1. Press the 

Illumination

 button (

9

) to switch the display off.

ð

The display switches off.

2. Press any button to switch on the device.

ð

The display switches on.

Using the horizontal oscillation function

The horizontal oscillation function ensures continuous air
circulation by moving the upper fan body (

1

) to the left and to

the right at an angle of 30°, 90°, 180° or 360°.

ü

The device is switched on and operating.

1. Press the 

Oscillation

 button (

13

) several times to activate

oscillation for the angle 30°, 90°, 180° or 360°.

ð

The corresponding 

Oscillation

 LED (

14

) will be

illuminated.

ð

The fan body (

1

) moves continuously to the left and

right.

1

2. If you press the 

Oscillation

 button (

13

) again, the oscillation

function will be switched off.

ð

The 

Oscillation

 LED (

14

) goes out.

ð

The device remains in the current position.

Activating the vertical swing function

The vertical swing function ensures continuous air circulation by
moving the upper fan body (

1

) upwards at an angle of 90° and

then to the initial position.

ü

The device is switched on and operating.

1. Press the 

Swing

 button (

15

) to activate the vertical swing

function.

ð

The 

Swing

 LED (

10

) is illuminated.

ð

The upper fan body (

1

) moves continuously upwards

and downwards.

1

2. If you press the 

Swing

 button (

15

) again, the swing

function will be switched off.

ð

The 

Swing

 LED (

10

) goes out.

ð

The device remains in the current position.

Info

You can activate the swing function and the oscillation
function at the same time.

Info

All functions can also be made using the remote
control included in the scope of delivery.

Summary of Contents for TVE 100

Page 1: ...TRT BA TVE100 TC211006TTRT01 002 EN TVE 100 EN OPERATING MANUAL 360 TURBO FAN ...

Page 2: ...he immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities...

Page 3: ... of air inlet and air outlet When unmounted the device should be neither operated nor connected to the mains Improper installation can lead to a fire electric shock or severe personal injury The device is provided with an overheating protection which is activated by overheating of the device when exceeding the operating temperature In such an event the device switches off automatically Do not inge...

Page 4: ...nel qualifications Warning The device is not a toy and does not belong in the hands of children Warning Risk of suffocation Do not leave the packaging lying around Children may use it as a dangerous toy Note Do not use abrasive cleaners or solvents to clean the device Behaviour in the event of an emergency 1 Switch the device off 2 In an emergency disconnect the device from the mains feed in Hold ...

Page 5: ...e mains plug while pulling the power cable out of the mains socket Do not use the power cable to drag the device After transporting the device proceed as follows Set up the device in an upright position after transport Storage Before storing the device proceed as follows Switch off the device Hold onto the mains plug while pulling the power cable out of the mains socket When the device is not bein...

Page 6: ...le position on firm ground Do not create tripping hazards when laying the power cable or other electric cables especially when positioning the device in the middle of the room Use cable bridges Make sure that extension cables are completely unrolled Make sure that no curtains or other objects interfere with the air flow Prior to initial start up insert batteries in the remote control Inserting bat...

Page 7: ...fan speed Decreasing the number of hours of the activated timer Switching the device on Once you have completely installed the device as described in the chapter Assembly and start up you can switch it on 1 Press the On off button 12 ð The On off LED 16 is illuminated ð An acoustic signal is emitted and the device starts up in Normal operation mode Info When the device is switched on the display i...

Page 8: ...r an operating time of 30 minutes After another 30 minutes the device switches to fan stage 10 and runs permanently at this stage Proceed as follows to switch on night mode 1 Press the Mode button 11 until the LED 17 is illuminated ð The device runs in night mode ð The LED is illuminated on the display 19 2 Turn the rotary switch 8 clockwise to increase the fan stage Turn the rotary switch 8 count...

Page 9: ...rizontal oscillation function ensures continuous air circulation by moving the upper fan body 1 to the left and to the right at an angle of 30 90 180 or 360 ü The device is switched on and operating 1 Press the Oscillation button 13 several times to activate oscillation for the angle 30 90 180 or 360 ð The corresponding Oscillation LED 14 will be illuminated ð The fan body 1 moves continuously to ...

Page 10: ... position Check whether the device is mounted correctly Note Wait for at least 3 minutes after maintenance and repair work Only then switch the device back on The device still does not operate correctly after these checks Please contact the customer service If necessary bring the device to an authorised specialist electrical company or to Trotec for repair Maintenance Activities required before st...

Page 11: ... an official recycling centre for electronic and electrical equipment authorised for your country The separate collection of waste electrical and electronic equipment aims to enable the re use recycling and other forms of recovery of waste equipment as well as to prevent negative effects for the environment and human health caused by the disposal of hazardous substances potentially contained in th...

Page 12: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...