Trotec TTK 171 ECO Original Instructions Manual Download Page 10

10

EN

dehumidifier TTK 171 ECO

Operation

Notes:

Avoid open doors and windows.

After being switched on, the device operates fully
automatically.

The compressor will additionally be switched on after
3 seconds.

The fan runs permanently in dehumidification mode until
the set nominal value is reached.

Operating elements

Timer

Plus

Minus

Continuous

Tank Full

Full

Cont

Defr ost Timer

15

16

17

18

19

20

21

22

23

24

25

No. Designation

Meaning

15

Tank Full

 LED

Is displayed when the condensation tank
is full or not installed correctly

16

Continuous

button

Selection button for the operating mode

continuous operation

17

Minus

 button

For reducing the desired relative
humidity level (20 % to 90 % in
increments of 5 %)
For reducing the value of the timer
programming in increments of 1 hour
(1 h to 24 h)

18 Segment display Indication of the current room humidity

level
Indication of the desired room humidity
level
Indication of the number of hours during
timer programming

19

Plus

 button

For increasing the desired relative
humidity level (20 % to 90 % in
increments of 5 %)
For increasing the value of the timer
programming in increments of 1 hour
(1 h to 24 h)

20

Timer

 button

For enabling or disabling the 

automatic

switch-on

 timer function

For enabling or disabling the 

automatic

switch-off

 timer function

21

On / Off

 button For switching the device on or off

No. Designation

Meaning

22

Timer

 LED

Illuminated when the timer for automatic
switch-on or switch-off is activated

23

Defrost

 LED

Is displayed when automatic defrosting
is in progress

24

Continuous

 LED Illuminated during 

continuous operation

25

Full

 LED

Is displayed when the condensation tank
is full or not installed correctly

Switching the device on

Once you have completely installed the device as described in
the Start-up chapter, you can switch it on.

1. Press the 

On / Off

 button (21).

ð

The device starts to dehumidify in continuous operation.

2. Press the 

On / Off

 button (21) again.

ð

Then the compressor switches off.

ð

- -

 will be indicated on the display.

ð

The device now switches over into standby mode.

ð

The fan keeps running for approx. one minute and then
switches off.

Continuous operation

The device dehumidifies the air constantly and regardless of the
relative room humidity.
The desired relative room humidity cannot be adjusted in this
operating mode.

1. Press the 

Continuous

 button (16).

ð

The 

Continuous

 LED (24) is illuminated.

ð

The segment display (18) indicates the current relative
room humidity.

ð

Continuous operation

 is selected.

Info

For continuous operation the condensation drain hose
can be connected in order to continuously drain the
accumulating condensate.

Summary of Contents for TTK 171 ECO

Page 1: ...TRT BA TTK171ECO TC2014 18 003 EN TTK 171 ECO EN ORIGINAL INSTRUCTIONS DEHUMIDIFIER...

Page 2: ...sing the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions...

Page 3: ...uction side is kept free of dirt and loose objects Do not remove any safety signs stickers or labels from the device Keep all safety signs stickers and labels in legible condition Only transport the d...

Page 4: ...ator until it is below the dew point Water vapour contained in the room air precipitates on the evaporator fins as condensation or rime The dehumidified cooled air is slightly warmed at the condenser...

Page 5: ...5 11 10 6 8 9 7 No Designation 1 Transport handle 2 Operating element 3 Recessed handle 4 Transport wheel 5 Feed through for condensation drain hose 6 Air outlet 7 Condensation tank 8 Venting slots 9...

Page 6: ...ore switching the device back on Acting contrary might lead to compressor damage and a malfunctioning device If so any warranty claims will be voided Storage Before storing the device observe the foll...

Page 7: ...s and the axle must be attached to the device To do so please proceed as follows The device is placed on its front side 1 Place a washer 12 on the axle 13 2 Place a wheel 4 in front of the washer 3 Pl...

Page 8: ...ng the device check the condition of the power cable If there are doubts as to the sound condition contact the customer service Set the device up in an upright and stable position Do not create trippi...

Page 9: ...the device will be heavily contaminated This could reduce the performance and result in damage to the device Make sure that the air filter is installed before switching the device on Inserting the con...

Page 10: ...witch on timer function For enabling or disabling the automatic switch off timer function 21 On Off button For switching the device on or off No Designation Meaning 22 Timer LED Illuminated when the t...

Page 11: ...automatic switch on upon expiry of a preset number of hours automatic switch off upon expiry of a preset number of hours The function can be set in all operating modes and also during stand by The nu...

Page 12: ...switch on If the device is disconnected from the power supply all settings for automatic switch on are deleted Manually switching the device on disables the automatic switch on function If you select...

Page 13: ...vice is running but there is no formation of condensate Check whether the condensation drain hose is positioned correctly Check the float in the condensation tank for dirt If necessary clean the conde...

Page 14: ...de of the device is dirty have it cleaned by a specialist company for cooling and air conditioning or by Trotec Note Wait for at least 3 minutes after maintenance and repair work Only then switch the...

Page 15: ...t least annually Check air inlets and outlets for dirt and foreign objects and clean if necessary X X Clean the exterior X X Visually check the inside of the device for dirt X X Check the air filter f...

Page 16: ...irt Check the air filter for dirt and foreign objects and clean or replace if necessary Replace the air filter Check for damage Check the attachment screws Test run Empty the condensation tank and dra...

Page 17: ...side of the device for dirt 4 If you see a thick layer of dust have the inside of the device cleaned by a specialist company for cooling and air conditioning or by Trotec 5 Put the air filter back in...

Page 18: ...float when inserting or removing the condensation tank In doing so make sure that the float is positioned correctly Also make sure that the condensation tank is inserted correctly otherwise the devic...

Page 19: ...ulates that this equipment must not be disposed of with the household waste at the end of its life You will find collection points for free return of waste electrical and electronic equipment in your...

Page 20: ...inery Directive in the version 2006 42 EC Product model Product TTK 171 ECO Product type dehumidifier Year of manufacture as of 2018 Relevant EU directives Applied harmonised standards EN ISO 12100 20...

Page 21: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: