EN
Operating Manual – Dehumidifier TTK 128 E
6
Operating elements
Switching the device on
1. Ensure that the condensation tank is empty and inserted
correctly. Otherwise, the device will not operate!
2. Insert the mains plug into a properly secured mains power
socket.
3. Open the fins at the air outlet (2).
4. Press the POWER button (14).
5. Press the SPEED button (15) to select the desired fan speed.
6. Press HUMIDITY SETTING (18) to set the desired humidity
level.
Setting the humidity level
Note:
The selected humidity value must not be higher than the current
humidity level in the room where the device is positioned.
The humidity level can be adjusted in steps of 5 % in the range
between 20 % and 90 %. The set humidity value is indicated on
the display (16).
• Press HUMIDITY SETTING (18) to set the desired humidity
level.
Selecting the fan speed
The fan speed setting can be adjusted to either high or low.
• Press the SPEED button (15) to select the desired fan speed.
– The indicator light HI (12) is illuminated at high fan speed.
– The indicator light LOW (11) is illuminated at low fan speed.
Continuous operation mode
In continuous operation mode, the device dehumidifies the air
constantly, regardless of the humidity in the air.
The condensate is collected in the condensation tank or drained
separately.
For separate draining, both a suitable hose (ø
½
") and a
sufficiently dimensioned collection container or drain are
required.
Start the continuous operation mode as follows:
1. Switch off the device.
2. If you want to drain the condensate separately, remove the
condensation tank (7) and carry out steps 3. and 4. If you
want to collect the condensate in the condensation tank,
proceed with step 5.
3. Connect a suitable hose (ø
½
") to the hose connector (6) and
introduce it into an appropriate condensate collection
container.
– Make sure that the container is located at a lower level than
the hose connector.
– During operation, make sure that the condensate collection
container does not overflow to avoid water damage.
4. Put the condensation tank (7) back in.
– In doing so, make sure not to crush the hose.
5. Press HUMIDITY SETTING (18) until "CO" is displayed.
– The dehumidifier now works in continuous operation mode.
No.
Designation
8
DEFROST indicator light
9
TANK FULL indicator light
10
TIMER indicator light
11
Indicator light LOW
12
Indicator light HI
13
Indicator light OPERATION
14
POWER button
15
SPEED button
16
Display
17
TIMER button
18
HUMIDITY SETTING button
10
16
9
8
17
18
15
14
13
12
11
Summary of Contents for TTK 128 E