background image

EN

Operating Manual – Dehumidifier TTK 128 E

6

Operating elements

Switching the device on

1. Ensure that the condensation tank is empty and inserted

correctly. Otherwise, the device will not operate!

2. Insert the mains plug into a properly secured mains power

socket.

3. Open the fins at the air outlet (2).

4. Press the POWER button (14).

5. Press the SPEED button (15) to select the desired fan speed.

6. Press HUMIDITY SETTING (18) to set the desired humidity

level.

Setting the humidity level

Note:
The selected humidity value must not be higher than the current
humidity level in the room where the device is positioned.

The humidity level can be adjusted in steps of 5 % in the range
between 20 % and 90 %. The set humidity value is indicated on
the display (16).

• Press HUMIDITY SETTING (18) to set the desired humidity

level.

Selecting the fan speed

The fan speed setting can be adjusted to either high or low. 

• Press the SPEED button (15) to select the desired fan speed.

– The indicator light HI (12) is illuminated at high fan speed. 

– The indicator light LOW (11) is illuminated at low fan speed.

Continuous operation mode

In continuous operation mode, the device dehumidifies the air
constantly, regardless of the humidity in the air. 
The condensate is collected in the condensation tank or drained
separately.
For separate draining, both a suitable hose (ø 

½

") and a

sufficiently dimensioned collection container or drain are
required.
Start the continuous operation mode as follows:

1. Switch off the device. 

2. If you want to drain the condensate separately, remove the

condensation tank (7) and carry out steps 3. and 4. If you
want to collect the condensate in the condensation tank,
proceed with step 5.

3. Connect a suitable hose (ø 

½

") to the hose connector (6) and

introduce it into an appropriate condensate collection
container.

– Make sure that the container is located at a lower level than

the hose connector.

– During operation, make sure that the condensate collection

container does not overflow to avoid water damage.

4. Put the condensation tank (7) back in.

– In doing so, make sure not to crush the hose.

5. Press HUMIDITY SETTING (18) until "CO" is displayed.

– The dehumidifier now works in continuous operation mode.

No.

Designation

8

DEFROST indicator light

9

TANK FULL indicator light

10

TIMER indicator light

11

Indicator light LOW

12

Indicator light HI

13

Indicator light OPERATION

14

POWER button

15

SPEED button

16

Display

17

TIMER button

18

HUMIDITY SETTING button

10

16

9

8

17

18

15

14

13

12

11

Summary of Contents for TTK 128 E

Page 1: ...TTK 128 E TRT BA TTK128E TC 001 EN OPERATING MANUAL DEHUMIDIFIER EN...

Page 2: ...rt of this publication may be reproduced without written permission from Trotec The same applies for electronically processing duplicating or spreading the publication Subject to technical changes All...

Page 3: ...ta Intended use comprises drying and dehumidifying living rooms bedrooms or basements laundries holiday homes maintaining the dryness of storage spaces archives laboratories museums garages changing r...

Page 4: ...ing the defrost phase through the integrated drain nozzle into the condensation tank 7 below It is fitted with a float to measure the filling level The device has a control panel 1 for operating and c...

Page 5: ...ative humidity 30 to 90 Air flow rate max 380 m h Mains connection 1 N PE 230 V 50 Hz Power consumption acc to EN 60335 1150 W Nominal current 5 1 A Condensation tank 7 2 l Refrigerant R410A Amount of...

Page 6: ...pter Technical Data After being switched on the device operates fully automatically Avoid open doors and windows Positioning When positioning the device observe the minimum distance from walls or othe...

Page 7: ...device dehumidifies the air constantly regardless of the humidity in the air The condensate is collected in the condensation tank or drained separately For separate draining both a suitable hose and...

Page 8: ...not turn off the device during the automatic defrost Do not remove the mains plug from the mains socket If the room temperature is less than 5 C switch the device off Wait for at least 3 minutes befor...

Page 9: ...oat in the condensation tank for dirt If necessary clean the float and condensation tank The float must be able to move freely Check the room temperature Observe the device s permissible operating ran...

Page 10: ...ings of the device 3 Check the inside of the device for dirt 4 If you see a thick layer of dust have the inside of the device cleaned by a specialist company for cooling and air conditioning or by Tro...

Page 11: ...port 23 front blade 39 float 8 discharge pipe 24 control plate 40 water tank 9 side panel 25 back panel 41 base 10 holder of 26 air filter 42 right support blade 11 capacitor 27 foam cutting piece a 4...

Page 12: ...e appropriately and according to the national regulations in accordance with the EC Low Voltage Directive 2006 95 EC Annex III Section B and the Directive 2014 30 EU about electromagnetic compatibilit...