infrared heating panel TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S

Information requirements for electrical local space heaters

Parameter

Value/item

Model

TIH 300 S

TIH 400 S

TIH 500 S

Heat output

Nominal heat output P

nom

0.3 kW

0.4 kW

0.5 kW

Minimum heat output (indicative) P

min

NA

NA

NA

Maximum continuous heat output P

max,c

0.3 kW

0.4 kW

0.5 kW

Auxiliary electricity consumption

At nominal heat output el

max

0.312 kW

0.418 kW

0.566 kW

At minimum heat output el

min

NA

NA

NA

In standby mode el

sb

NA

NA

NA

Type of heat input

Manual heat charge control, with integrated thermostat

NA

NA

NA

Manual heat charge control with room and/or outdoor temperature
feedback

NA

NA

NA

Electronic heat charge control with room and/or outdoor temperature
feedback

NA

NA

NA

Fan assisted heat output

NA

NA

NA

Type of heat output/room temperature control

Single stage heat output, no room temperature control

NO

NO

NO

Two or more manual stages, no room temperature control

NO

NO

NO

With mechanic thermostat room temperature control

NO

NO

NO

With electronic room temperature control

NO

NO

NO

With electronic room temperature control plus day timer

NO

NO

NO

With electronic room temperature control plus week timer

YES

YES

YES

Other control options

Room temperature control, with presence detection

NO

NO

NO

Room temperature control, with open window detection

NO

NO

NO

With distance control option

NO

NO

NO

With adaptive start control

YES

YES

YES

With working time limitation

NO

NO

NO

With black bulb sensor

NO

NO

NO

Contact details

Trotec GmbH & Co. KG
Grebbener Straße 7
D-52525 Heinsberg

NA = not applicable

Summary of Contents for TIH1100S

Page 1: ...500S TIH700S TIH900S TIH1100S TC2015 37 005 EN TIH 300 S TIH 400 S TIH 500 S TIH 700 S TIH 900 S TIH 1100 S EN OPERATING MANUAL INFRARED HEATING PANEL EN This product is only suitable for well insulated spaces or occasional use ...

Page 2: ...rage risk level which if not avoided can result in serious injury or death Caution This signal word indicates a hazard with a low risk level which if not avoided can result in minor or moderate injury Note This signal word indicates important information e g material damage but does not indicate hazards Info Information marked with this symbol helps you to carry out your tasks quickly and safely F...

Page 3: ...device during operation Do not remove any safety signs stickers or labels from the device Keep all safety signs stickers and labels in legible condition Do not sit on the device This appliance is not a toy Keep away from children and animals Do not leave the device unattended during operation Check accessories and connection parts for possible damage prior to every use of the device Do not use any...

Page 4: ...ing manual especially the Safety chapter Maintenance tasks which require the housing to be opened must only be carried out by specialist electrical companies or by Trotec Symbols on the device Symbols Meaning This symbol located on the device indicates that it is prohibited to place objects such as towels clothes etc above or directly in front of the device In order to avoid overheating and fire h...

Page 5: ...o the mains plug while pulling the power cable out of the mains socket 2 Do not reconnect a defective device to the mains Information about the device Device description The device TIH 300 S TIH 400 S TIH 500 S TIH 700 S TIH 900 S TIH 1100 S is used to quickly generate instant heat The device is based on the functional principle of heat generation by infrared radiation Persons or objects are heate...

Page 6: ... cover to protect it from invasive dust if necessary Place no further devices or objects on top of the device to prevent it from being damaged Assembly and installation Scope of delivery 1 x IR heating panel 4 x Screw 4 x Dowel 1 x Manual Unpacking the device 1 Open the cardboard box and take the device out 2 Completely remove the packaging 3 Fully unwind the power cable Make sure that the power c...

Page 7: ...rox 0 5 cm from the wall plugs 7 Hang the device in Assembling the feet optional The feet can optionally be attached to the device in order to be able to position the device in the room The accessories for the feet are not included in the scope of delivery When positioning the device observe the minimum distance from walls or other objects as described in the Technical data chapter For assembling ...

Page 8: ...ains or similar objects in the immediate vicinity Connecting the power cable Insert the mains plug into a properly secured mains socket Operation Info Avoid open doors and windows Switching the device on Once you have completely installed or positioned the device as described in the Start up chapter you can switch it on 1 Plug the mains plug into a sufficiently fused mains socket Make sure that th...

Page 9: ...on The material expands due to heating The insulation expands as well and generates the noises This is a perfectly normal process No measures are required Note Wait for at least 3 minutes after maintenance and repair work Only then switch the device back on Your device still does not operate correctly after these checks Please contact the customer service If necessary bring the device to an author...

Page 10: ... 22 mm 705 x 605 x 22 mm 905 x 605 x 22 mm Minimum distances top A rear B sides C front D 50 cm 0 cm 10 cm 30 cm 50 cm 0 cm 10 cm 30 cm 50 cm 0 cm 10 cm 30 cm Parameter Value Model TIH 700 S TIH 900 S TIH 1100 S Article number 1 410 003 014 1 410 003 016 1 410 003 018 Heating capacity 700 W 5 900 W 5 1100 W 5 Mains connection 1 N PE 230 V 50 Hz 1 N PE 230 V 50 Hz 1 N PE 230 V 50 Hz Nominal current...

Page 11: ...c heat charge control with room and or outdoor temperature feedback NA NA NA Fan assisted heat output NA NA NA Type of heat output room temperature control Single stage heat output no room temperature control NO NO NO Two or more manual stages no room temperature control NO NO NO With mechanic thermostat room temperature control NO NO NO With electronic room temperature control NO NO NO With elect...

Page 12: ...ic heat charge control with room and or outdoor temperature feedback NA NA NA Fan assisted heat output NA NA NA Type of heat output room temperature control Single stage heat output no room temperature control NO NO NO Two or more manual stages no room temperature control NO NO NO With mechanic thermostat room temperature control NO NO NO With electronic room temperature control NO NO NO With elec...

Page 13: ... waste electrical and electronic equipment in your vicinity The addresses can be obtained from your municipality or local administration For further return options provided by us please refer to our website www trotec24 com The separate collection of waste electrical and electronic equipment aims to enable the re use recycling and other forms of recovery of waste equipment as well as to prevent ne...

Page 14: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Reviews: