background image

4

Operating Manual – Radial Fan TFV 900

EN

• Remove all packing materials which serve to protect the

device during transport.

• Should the device be damaged, please contact the

responsible dealer or manufacturer, where the purchase was
made.

• The device with frame may only be lifted at the points

provided with lifting gear (forklift pockets (6), crane lifting
lugs (2)). 
The carrying capacity of the lifting gear must be suitable for
the weight of the device (see Technical data).

• The device without frame may only be lifted at the lifting lugs

provided at motor and fan. The carrying capacity of the lifting
gear must be suitable for the weight of the device (see
Technical data).

• For transport with a forklift drive in from the motor side, that's

where the centre of gravity is to be found. The other forklift
pockets are for the later fine adjustment on site.

• Only wheel the device with frame on firm, level ground. Make

sure that nobody is situated in the direction of movement.
Avoid pulling the device, this increases the risk of tripping
and injury.

The following should be observed 

before

 transporting the device

using the 

castors

:

Caution!

Trip hazard! Make sure that nobody is situated in the
immediate proximity.

The following should be observed 

before

 transporting the device

using 

lifting gear

:

Danger!

Risk of injury from suspended loads. Make sure that
nobody is situated in the immediate proximity.

• Only instructed persons are allowed to perform the transport

by use of lifting gear.

• Consider the centre of gravity when transporting the load.

Storage

• Store the cleaned device in a dry location and protect it

against dust. 

• Before restarting the device, check the power cable for

perfect condition. 

Installation of the device

• Position the device on firm, dry and level ground. Depending

on the permissible floor load capacity a panel for weight
distribution may be required.

• When setting up the device, ensure a sufficient distance for

air inlet and outlet as well as for operation (see Technical
data
).

• Ensure that extension cords are completely unrolled.

• Option with frame: 

Apply the parking brakes prior to

start-up

 and secure the device against rolling away.

The following points are to be checked 

before

 start-up:

• Make sure that both air inlet and air outlet are free from

objects and/or obstacles.

• Manually check the freewheeling of the fan:

– Carefully rotate the rotor by hand, it should not rub against

the housing.

• Connect the required air transport hoses with suitable tension

belts with clamping lock to the air intake connection (8) or as
needed to the air exhaust connection (5).

• Compare the values of the power connection to the technical

data of the TFV 900. Observe the starting current of the
device, the upstream fuse must be dimensioned accordingly.

• Before connecting the device to the mains, check the rotary

field: 

clockwise rotating field

 required!

• First connect the fan plug to the power cable and then the

cable to the distribution!

Transport and storage

Start-up

Summary of Contents for TFV 900

Page 1: ...TFV 900 OPERATING MANUAL RADIAL FAN EN TRT BA TFV900 TC 001 EN ...

Page 2: ......

Page 3: ...h and safety requirements of the applicable EU regulations and was tested at the factory for perfect functionality multiple times However if faults in the functionality occur and cannot be remedied with the measures in the chapter Errors and faults please get in touch with your dealer or distributor When invoking the guarantee the data given on the fan info sheet supplied with the device is to be ...

Page 4: ...TFV 900 is not suited for installation in fluids or on flooded or boggy grounds The device must not be used for transporting media other than atmospheric air e g fluids or other gases Any unauthorised changes modifications or alterations to the device are forbidden Personnel qualifications People who use this device must be aware of the dangers that occur when working with high pressure fans have ...

Page 5: ...elivered without a frame for stationary application Optionally the device is also available with a frame as depicted for variable areas of use As for a further option the device is also available as ex proof version for the use in potentially explosive surroundings only these devices may be operated in an explosive environment The radial fan is integrated in a powder coated steel housing with high...

Page 6: ... proximity Only instructed persons are allowed to perform the transport by use of lifting gear Consider the centre of gravity when transporting the load Storage Store the cleaned device in a dry location and protect it against dust Before restarting the device check the power cable for perfect condition Installation of the device Position the device on firm dry and level ground Depending on the pe...

Page 7: ...o delta Hence it supplies its maximum conveying capacity for continuous operation Switch off 1 Press the red Control off button 12 The Operation lamp 10 goes out The fan resumes in rundown operation for a few seconds and then comes to a halt From this operating condition you can switch the device back on at any time Shutdown 1 Switch the device off as previously described 2 Upon standstill of the ...

Page 8: ...main switch Before any work detach the mains plug Repair work may only be performed by qualified electricians or Trotec Cleaning the fan You may use compressed air for a thorough cleaning of the fan Do not use a high pressure cleaner for the fan Always pay attention to unusual sounds if in doubt consult the manufacturer Errors and faults Fault Cause Possible solution The motor does not start or au...

Page 9: ...medium temperature 80 C Nominal voltage 3 N PE 400 V 50 Hz Rotary field clockwise rotating field Nominal current 32 A Recommended fusing 32 A gL Nominal capacity 18 5 kW Surrounding conditions permissible temperature range type of protection 20 C to 40 C IP 55 Mains plug CEE 32 A Engine start up star delta changeover Noise level at a distance of 1 m 82 dB A Weight without frame option with frame 4...

Page 10: ...ed TFV 900 7141000626 4 see separate list 9 15 to 13 12 SP button red TFV 900 7130000092 5 SP air exhaust connection d 630mm 7230000002 13 SP button green TFV 900 7130000093 5b SP air exhaust connection d 600mm 7230000005 14 SP contactor control TFV 900 7140000122 7 SP castor TFV900 7600000245 16 SP changeover switch star delta K1 TFV 900 7140000120 8 SP air intake connection TFV 900 d 630mm 72300...

Page 11: ...aintenance etc or unauthorized changes of the factory supplied device version this declaration loses its legal validity Device version radial fan Models TFV 900 Year of manufacture as of 2009 Applicable regulations 2006 42 EC 2006 95 EC 2004 108 EC Machinery Directive Low Voltage Directive EMC Directive Applied harmonised standards EN 12100 1 2 2007 EN 13857 2008 EN 60204 1 2006 EN 60034 1 2007 EN...

Page 12: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...