Operating manual – turbo fan TFV 10 / TFV 20 / TFV 30

Available accessories

TFV 20

Accessories

Article number

Hose adapter (two-way hose
distributor, 2 x Ø 100 mm), 
incl. one sealing cap

6.100.005.055

Air hose Tronect TF-L,
Ø 100 mm, 
length 6 m

6.100.001.115

Hose clamp 80 – 130 mm

6.100.009.079

TFV 30

Accessories

Article number

Hose adapter (three-way hose
distributor, 3 x Ø 100 mm), 
incl. two sealing caps

6.100.005.061

Air hose Tronect TF-L,
Ø 100 mm, 
length 6 m

6.100.001.115

Hose clamp 80 – 130 mm

6.100.009.079

Errors and faults

The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.

The device does not start:

Check the power connection.

Check the power cable and mains plug for damages.

Check the on-site fusing.

Wait for 10 minutes before restarting the device. If the
device is not starting, have the electrics checked by a
specialist company or by Trotec.

The fan operates only for a brief period, then switches off:

Check whether the protective grid at the air inlet is
obstructed in some way. If applicable, remove foreign
objects.

The motor bearing might be damaged. Please contact the
customer service.

The fan is not running:

Check whether the device is switched on.

Check the power connection.

Check the power cable and mains plug for damages.

Check the on-site fusing.

Note

Wait for at least 3 minutes after maintenance and
repair work. Only then switch the device back on.

Your device still does not operate correctly after these
checks?

Please contact the customer service. If necessary, bring the
device to an authorized specialist electrical company or to
Trotec for repair.

Maintenance

Activities required before starting maintenance

Warning of electrical voltage

Do not touch the mains plug with wet or damp hands.

Switch the device off.

Hold onto the mains plug while pulling the power cable out
of the mains socket.

Cleaning the housing

Clean the housing with a soft, damp and lint-free cloth. Ensure
that no moisture enters the housing. Protect electrical
components from moisture. Do not use any aggressive cleaning
agents such as cleaning sprays, solvents, alcohol-based or
abrasive cleaners to dampen the cloth.

Cleaning the fan and device interior

Check fan and protective grid for perfect condition before
and after each application.

Clean the fan after each operation.

Use compressed air to remove particles, lint, dust and dirt
from motor, fan wheel and protective grid. Do not in any
event use a high-pressure cleaner to clean the fan.

Other than that, the device does not require maintenance.

Summary of Contents for TFV 20

Page 1: ...TRT BA TFV10 TFV20 TFV30 TC 002 EN TFV 10 TFV 20 TFV 30 EN OPERATING MANUAL TURBO FAN ...

Page 2: ...ry or death Caution This signal word indicates a hazard with a low risk level which if not avoided can result in minor or moderate injury Note This signal word indicates important information e g material damage but does not indicate hazards Info Information marked with this symbol helps you to carry out your tasks quickly and safely Follow the manual Information marked with this symbol indicates ...

Page 3: ...ctric cables or the power connection are damaged The electrical connection must correspond to the specifications in chapter Technical data Insert the mains plug into a properly secured mains socket Observe the technical data when selecting extensions to the power cable Completely unroll the extension cable Avoid electrical overload Before carrying out maintenance care or repair work on the device ...

Page 4: ... description The devices TFV 10 TFV 20 TFV 30 were designed for a very high air flow rate They may be used for drying carpets buildings or screed as well as for the ventilation of poorly accessible intermediate spaces Owing to the high air circulation the devices can also be used to control excessive humidity levels The fan is also very effective for the additional air circulation when heating lar...

Page 5: ... fan stage selection 2 Operating hours counter 3 Transport handle 4 Air outlet 5 Skids 6 Air inlet 7 Cable holder TFV 20 1 11 8 4 3 6 5 7 No Designation 1 Switch for fan stage selection 3 Transport handle 4 Air outlet 5 Skids 6 Air inlet 7 Cable holder 8 Service power socket 11 Dual counter operating and kilowatt hours ...

Page 6: ... Hold onto the mains plug while pulling the power cable out of the mains socket Do not use the power cable to drag the device After transporting the device observe the following Set up the device in an upright position after transport Storage Before storing the device observe the following When the device is not being used observe the following storage conditions dry and protected from frost and h...

Page 7: ...al three way hose distributor Info Seal off unused connections by means of suitable sealing caps and possibly with hose clamps to prevent a decrease in the air flow rate Info The procedure of fitting a hose distributor is described below using the example of a three way hose distributor that is connected to the TFV 30 however it applies accordingly to the TFV 20 and a two way hose distributor 1 Op...

Page 8: ...hoses for tight fit Start up Positioning Set the device up separately and in a stable position The device can be variably positioned in a way to allow an air discharge at an angle of 0 45 or 90 0 45 90 Connecting the power cable Insert the mains plug into a properly secured mains socket Operation Operating elements TFV 10 1 No Designation 1 Switch for fan stage selection ...

Page 9: ...fan stage stage 1 LOW stage 2 MEDIUM stage 3 HIGH ð The device is switched on Dual counter TFV 20 and TFV 30 The devices TFV 20 TFV 30 are equipped with a dual counter 11 The operating hours are indicated in the upper section of the counter the kilowatt hours are displayed just below The kWh counter is certified according to MID The LED 10 is illuminated as soon as a current flow is established Us...

Page 10: ...r service The fan is not running Check whether the device is switched on Check the power connection Check the power cable and mains plug for damages Check the on site fusing Note Wait for at least 3 minutes after maintenance and repair work Only then switch the device back on Your device still does not operate correctly after these checks Please contact the customer service If necessary bring the ...

Page 11: ...30 V 50 Hz 5 2 A Power input max 0 85 kW Stat air pressure freely blowing max 425 Pa Protection type IP22 Sound level distance 3 m Stage 1 Stage 2 Stage 3 73 5 dB A 80 8 dB A 86 2 dB A Dimensions L x W x H 440 x 440 x 440 mm Weight 18 5 kg Disposal The icon with the crossed out waste bin on waste electrical or electronic equipment stipulates that this equipment must not be disposed of with the hou...

Page 12: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Reviews: