EN
10
Operating manual – designer glass convector TCH 2000 E
Switching the device on
Once you have completely installed the device as described in
the Start-up chapter, you can switch it on.
1. Set the on/off switch (4) to
I
.
ð
An acoustic signal is emitted.
ð
The device is now in standby mode.
2. Press the
power
button (21).
ð
The device starts in
frost monitor heating mode
.
ð
The
frost monitor heating mode
indication (12) is
displayed with a flashing black frame.
Setting the operating mode
Mode
The following types of heating can be selected:
•
Comfort heating mode
(heating capacity 2000 W)
•
Economy heating mode
(heating capacity 1000 W)
•
Frost monitor heating mode
1. Press the
MODE
button (20) until the desired heating mode
is selected.
ð
The selected mode and the
heating 1
indication (13) are
displayed with a black frame.
ð
The
heating 2
indication (14) is displayed in
comfort
heating mode
and in
economy heating mode
, but not in
frost monitor heating mode
.
Comfort heating mode
The device operates with a heating capacity of 2000 W until
reaching the desired room temperature. When the desired room
temperature is reached, the device reduces the heating capacity
to 1000 W. The
comfort heating mode
indication (10) continues
to be displayed.
If the determined room temperature exceeds the desired room
temperature by 2 °C, the heating switches off.
The
heating 1
indication (13) is no longer framed and the
heating 2
indication (14) goes out.
If the determined room temperature falls below the desired
room temperature by 5 °C, the heating switches back to
comfort heating mode
.
Economy heating mode
The device operates with a heating capacity of 1000 W until the
determined room temperature exceeds the desired room
temperature by 2 °C. Then the heating switches off.
The
heating 1
indication (13) is no longer framed and the
heating 2
indication (14) goes out.
If the determined room temperature falls below the desired
room temperature by 5 °C, the heating switches back to
economy heating mode
.
Frost monitor heating mode
In
frost monitor heating mode
the devices heats automatically if
the room temperature is below 5 °C. This temperature cannot
be changed.
Setting the desired room temperature
The room temperature determined by the temperature
sensor (9) is displayed on the
temperature
indication (24). You
can set the desired room temperature at any time.
The room temperature is preset to 35 °C.
1. Press the
TEMP
button (16).
ð
The
temperature
indication (24) flashes.
ð
The desired room temperature is displayed.
2. Press the arrow buttons
increase value
(18) or
decrease
value
(19) to adjust the desired room temperature. Setting is
possible in the range between 15 °C and 50 °C in
increments of 1 °C.
ð
The desired room temperature is saved and shown on
the
temperature
indication (24) for approx. 5 seconds.
Then the current room temperature is displayed again.
Info
The desired room temperature should be higher than
the current room temperature.
Setting the timer
The timer has two modes of operation:
•
automatic switch-on upon expiry of a preset number of
hours.
•
automatic switch-off upon expiry of a preset number of
hours.
The timer run-time can be between 1 minute and 24 hours and
can be adjusted in increments of 1 min.
Note:
Do not leave the operating device unattended in a freely
accessible room with an activated timer.