7
Operating manual – Material moisture measuring device T510
EN
Adjusting the display illumination
The display illumination can be adjusted within a range of 20 to
100 %. Another available setting is AL.on. AL.on features a
brightness of 100 % and deactivates the automatic switch-off
function.
1. Select the lamp (18) whilst in configuration mode.
2. Press the OK button (10) to confirm.
3. Select the desired value by use of the Up (7) or Down (9) key.
4. Press the OK button (10) for approx. 2 seconds.
– The set value will be adopted.
The device switches to measuring mode.
Setting the alarm
Here you can determine the limit value for the alarm function.
Upon exceeding this value, the device emits an acoustic signal
and the indication ALARM (18) flashes. The alarm function draws
on the current measured value. The limit value can be determined
within a range of 0 to 100.
1. Select ALARM (18).
2. Press the OK button (10) to confirm.
– The upper measurement value display (14) flashes.
3. Press the Up (7) or Down (9) key to activate or deactivate the
alarm.
–
On
or
Off
will be indicated in the upper measurement value
display (14).
4. Press the Right key (8).
– Depending on the selection, the alarm is either activated or
deactivated.
– The lower measurement value display (16) flashes.
5. Press the keys Right/back (8) or Left/menu (11) to select a
digit.
– The selected digit flashes.
6. Press the Up (7) or Down (9) key to change the value of the
selected digit.
7. Repeat the steps 5. and 6. until the value is set as desired.
8. Press the OK button (10) for approx. 2 seconds.
– The alarm was set based on your choice.
– The device switches to measuring mode.
– With activated alarm function the indication ALARM (18)
continues to be displayed.
Material settings
Please note that this function can only be selected for wood mois-
ture measuring.
1. Select MAT (18) whilst in configuration mode.
2. Press the OK button (10) for approx. 2 seconds.
–
Code
be indicated in the upper measurement value display.
– The current material code (see chapter Table of wood
types) is indicated in the lower measurement value display.
3. Press the keys Right/back (8) or Left/menu (11) to select a
digit.
– The selected digit flashes.
4. Press the Up (7) or Down (9) key to change the value of the
selected digit.
5. Repeat the steps 3. and 4. until the value is set as desired.
6. Press the OK button (10) for approx. 2 seconds.
– The desired material is set.
– The device switches to measuring mode.
Setting the wood temperature
Please note that this function can only be selected for wood mois-
ture measuring.
Via this function you can determine the wood temperature in
degrees Celsius (°C) or Fahrenheit (°F). The wood temperature is
required by the device in order to determine the exact material
moisture.
Note:
Determine the wood temperature prior to the measurement, e.g.
using a pyrometer.
1. Select TEMP (18) whilst in configuration mode.
2. Press the OK button (10) for approx. 2 seconds.
– The currently set wood temperature is indicated in the low-
er measurement value display.
3. Use the keys Left or Right to select a digit.
– The selected digit flashes.
4. Press the Up (7) or Down (9) key to change the value of the
selected digit.
5. Repeat the steps 3. and 4. until the value is set as desired.
6. Press the OK button (10) for approx. 2 seconds.
– The wood temperature is set.
– The device switches to measuring mode.