TRT-BA-PT2700SP-TC220111TTRT04-001-EN
PT 2700 SP
EN
ORIGINAL INSTRUCTIONS
SPOT COOLING AIRCONDITIONING UNIT
Page 1: ...TRT BA PT2700SP TC220111TTRT04 001 EN PT 2700 SP EN ORIGINAL INSTRUCTIONS SPOT COOLING AIR CONDITIONING UNIT...
Page 2: ...ing or using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and inst...
Page 3: ...avoid fire or explosion hazards resulting from an ignition of the refrigerant by an electric furnace cooking stove or another ignition source Only position the device in rooms where there is no sourc...
Page 4: ...ns stickers and labels in legible condition The following safety signs and labels are attached to the device WARNING WARNUNG ATTENTION Follow the manual This symbol indicates that the operating manual...
Page 5: ...arning The device is not a toy and does not belong in the hands of children Warning Risk of suffocation Do not leave the packaging lying around Children may use it as a dangerous toy Warning Risk of d...
Page 6: ...d onto the mains plug while pulling the power cable out of the mains socket Drain the remaining condensate from the device Do not use the power cable to drag the device Only wheel the device on a leve...
Page 7: ...e there is no source of ignition e g open flames an active gas appliance or an electric heater Before restarting the device check the condition of the power cable If there are doubts as to the sound c...
Page 8: ...ace the cold air duct 9 on the angle flange 11 4 Turn the cold air duct 9 to the right until the cold air duct 9 engages unlock lock Klick 9 11 12 Connecting the hot air duct The hot air duct 1 must b...
Page 9: ...inside of the device will be heavily contaminated This could reduce the performance and result in damage to the device Make sure that the air filter is installed before switching the device on 1 If t...
Page 10: ...ry rooms and never immerse the device in water Switching the device on 1 Once you have completely installed the device as described in the Start up chapter you can switch it on 2 Set the function sele...
Page 11: ...e is not starting have the electrics checked by a specialist company or by Trotec The device works with reduced or no cooling capacity Check the air filter s for dirt If necessary clean or replace the...
Page 12: ...ensation tank and or drain hose X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and fore...
Page 13: ...place The entire refrigerant circuit is a maintenance free hermetically sealed system and may only be maintained or repaired by specialist companies for cooling and air conditioning or by Trotec Safe...
Page 14: ...e 4 Reinsert the air filter into the device 8 Condensate discharge manual draining In cooling mode condensate is formed which is mostly discharged via the exhaust air The remaining condensate is colle...
Page 15: ...Type of protection IPXO Max power input cooling operation 1 15 kW Sound pressure level at a distance of 1 m 55 dB A Refrigerant R290 Amount of refrigerant 250 g GWP factor 3 CO2 equivalent 0 00075 t P...
Page 16: ...700 SP Circuit diagram BL RD H FAN N N0 COM 30A RELAY WATER SWITCH YE GN GND LIGHT N L SWITCH L FAN XH 4 WTHF5VLF XH 2 WATER PCB BOARD WH RD RD BL FAN MOTOR YE FAN CAPACITOR YE BK BK BK M COMPRESSOR B...
Page 17: ...cooling air conditioning unit PT 2700 SP Overview and list of spare parts Note The position numbers of the spare parts differ from those describing the positions of other parts mentioned in this opera...
Page 18: ...ssembly 53 Water tank cover plate 10 Knob 32 Steaming tube ass 54 Water tank 11 Control panel label 33 Lower pressure tube 55 Magnetron switch support 12 Control box 34 Filter 56 Magnetically controll...
Page 19: ...nt certification European Waste Catalogue 160504 Only for United Kingdom According to Waste Electrical and Electronic Equipment Regulations 2013 2013 3113 power tools that are no longer usable must be...
Page 20: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...