12
EN
compressor PCPS 10-1100
Checking the pressure
1. Connect the compressed-air gun (12) to the compressor
(see chapter Connecting the compressed-air gun).
2. Check whether a valve adapter is required for the planned
activity and, if so, connect it.
3. Connect the compressed-air gun directly to the item to be
inflated by means of the mounted valve adapter.
ð
The current pressure of the connected item will be
indicated on the pressure gauge (10).
Inflating
1. Switch the device on by setting the on/off switch (2) to
position
I
.
ð
The compressor starts to build up pressure immediately
and is ready for use.
2. Pull and hold the trigger (14) until the desired pressure has
been reached on the pressure gauge (10).
14
3. Switch the device off by setting the on/off switch (2) to
position
0
.
Deflating
If the existing pressure is too high or if the desired pressure was
exceeded during inflation, the excess air can be released. To do
so, please proceed as follows:
1. Press and hold the deflation valve (11) until the pressure
has been reduced to the desired value displayed on the
pressure gauge (10).
11
2. Disconnect the quick-release lever or any adapter used
from the inflated item.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
•
Switch the device off.
•
Hold onto the mains plug while pulling the power cable out
of the mains socket.
•
If required, allow the device to cool down.
•
Disconnect any adapters used from the compressed-air
gun (12).
•
Disconnect the compressed-air gun (12) from the
compressor (see chapter Disconnecting the
compressed-air gun).
•
Clean the device according to the Maintenance chapter.
•
Store the device according to the Storage chapter.