background image

12

EN

compressor PCPS 10-1100

Checking the pressure

1. Connect the compressed-air gun (12) to the compressor

(see chapter Connecting the compressed-air gun).

2. Check whether a valve adapter is required for the planned

activity and, if so, connect it.

3. Connect the compressed-air gun directly to the item to be

inflated by means of the mounted valve adapter.

ð

The current pressure of the connected item will be
indicated on the pressure gauge (10).

Inflating

1. Switch the device on by setting the on/off switch (2) to

position 

I

.

ð

The compressor starts to build up pressure immediately
and is ready for use.

2. Pull and hold the trigger (14) until the desired pressure has

been reached on the pressure gauge (10).

14

3. Switch the device off by setting the on/off switch (2) to

position 

0

.

Deflating

If the existing pressure is too high or if the desired pressure was
exceeded during inflation, the excess air can be released. To do
so, please proceed as follows:

1. Press and hold the deflation valve (11) until the pressure

has been reduced to the desired value displayed on the
pressure gauge (10).

11

2. Disconnect the quick-release lever or any adapter used

from the inflated item.

Shutdown

Warning of electrical voltage

Do not touch the mains plug with wet or damp hands.

Switch the device off.

Hold onto the mains plug while pulling the power cable out
of the mains socket.

If required, allow the device to cool down.

Disconnect any adapters used from the compressed-air
gun (12).

Disconnect the compressed-air gun (12) from the
compressor (see chapter Disconnecting the 
compressed-air gun).

Clean the device according to the Maintenance chapter.

Store the device according to the Storage chapter.

Summary of Contents for PCPC 10-1100

Page 1: ...TRT BA PCPS10 1100 TC220330TTRT03 005 EN PCPS 10 1100 EN ORIGINAL INSTRUCTIONS COMPRESSOR...

Page 2: ...ormation marked with this symbol indicates that you should wear eye protection Wear a protective mask Information marked with this symbol indicates that you should wear a protective mask Wear protecti...

Page 3: ...door use Use of a cord suitable for outdoor use reduces the risk of electric shock If operating a power tool in a damp location is unavoidable use a residual current device RCD protected supply Use of...

Page 4: ...intained Device specific safety warnings for compressors and blow out guns Do not use the device in potentially explosive rooms or areas and do not install it there Make sure that the suction side is...

Page 5: ...ed on its rubber feet or the bottom side Never exceed the inclination angle of 10 vertical pos or 15 horizontal pos Intended use Only use the device PCPS 10 1100 for inflating car tyres bicycle tyres...

Page 6: ...and does not belong in the hands of children Warning Risk of suffocation Do not leave the packaging lying around Children may use it as a dangerous toy Caution Keep a sufficient distance from heat sou...

Page 7: ...ation 1 Transport handle 2 On off switch with protective cover 3 Storage compartment for compressed air hose 4 Compressed air hose with quick coupling 5 3 fold nozzle attachments 6 Ball needle 7 Unive...

Page 8: ...Wear hearing protection Excessive noise can lead to hearing loss Transport and storage Note If you store or transport the device improperly the device may be damaged Note the information regarding tr...

Page 9: ...into place The compressed air gun is connected 13 21 Disconnecting the compressed air gun Warning Risk of injury due to whipping compressed air hose Disconnecting the compressed air hose while the sy...

Page 10: ...an inner diameter of 8 mm or more To connect one of the nozzles via the nozzle adapter please proceed as follows The device is switched off 1 Push the quick release lever 22 at the hose 15 of the comp...

Page 11: ...only want to check or reduce the pressure e g in a car tyre it is not necessary to switch the device on 1 Connect the device to the mains 2 Switch the device on by setting the on off switch 2 to posit...

Page 12: ...ng the on off switch 2 to position 0 Deflating If the existing pressure is too high or if the desired pressure was exceeded during inflation the excess air can be released To do so please proceed as f...

Page 13: ...em to be inflated has exceeded the ambient pressure Check the item to be inflated for leaks Check the compressed air gun for proper functioning and replace it if necessary The device is running but th...

Page 14: ...sure that no moisture enters the housing Protect electrical components from moisture Do not use any aggressive cleaning agents such as cleaning sprays solvents alcohol based or abrasive cleaners to da...

Page 15: ...22 Guaranteed sound power level LWA 97 dB A Relevant EU directives 2005 88 EC 14 Dec 2005 2011 65 EU 01 07 2011 2014 30 EU 29 03 2014 Applied harmonised standards EN 1012 1 2010 EN 55014 1 2017 A11 20...

Page 16: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: