Recommendations for optimum unit operation
1. In case of direct sunlight, make sure to close all curtains and blinds
2. Keep doors and windows closed during operation
Expelling warm air
During cooling mode, the unit generates warm air. This air must be expelled from the room being cooled to retain the cooling
effect. It is therefore necessary to insert the supplied exhaust hose into the air outlet opening at the back of the unit.
•
Make sure that the deflector piece from the top slides down into the notches on the side until it clicks into place
•
To ensure that the unit operates effectively, do not place the flexible exhaust hose supplied at sharp angles and make
sure there are no kinks
•
You may not extend the exhaust hose
•
The air expelled from the hose contains a certain amount of moisture. We therefore recommend expelling the air to the
surroundings or the outside
Initial Operation
Prior to initial operation, the air intake and outlet openings must be inspected for foreign bodies and the air intake filter for dirt.
Blocked or dirty grilles and filters must be cleaned immediately.
Cooling operating mode
1. Switch the unit on with the power button
2. Select the cool operating mode and the cool signal light will illuminate
3. Set the desired target temperature with the timer/temp adjust button.
(The room temp signal light will disappear, the
set temp light illuminates and the selected target temperature appears on the display)
4. Select the desired fan speed
Dehumidifying operating mode
The dehumidifying operating mode is very different from the cooling operating mode with respect to the drainage of condensation
Important information on condensation drainage
•
Set up the unit in the room to be dehumidified and do not guide the exhaust hose to the outside. The warm air remains
in the room, thus improving the dehumidifying performance of the unit
•
The exhaust fan may not expel the accumulated condensation again via the exhaust hose to the air in the room in
dehumidification mode. To prevent this from occurring, the internal tank must be emptied on a regular basis
1. Switch the unit on using the power button
2. Select the dehumidifier operating mode and the dehumidification light will illuminate
3. Set the lowest target temperature of 16°C with the timer/temp adjust button.
(The med fan speed is preset and cannot
be changed)
4. Pull the plug from the condensation drain, collect the water and guide it via a hose to a drain at a lower level
5. Make sure that if there is an external container, it does not overflow.
(This can result in water damage)
6. After the dehumidifier operation is complete, reinsert the plug of the condensation drain.
(Keep in mind that if there is
no plug or it is inserted incorrectly, water may leak out)
Fan operating mode (Circulation)
1. Switch the unit on using the power button
2. Select the fan operating mode and the fan light will illuminate
3. Select the desired fan speed using the fan speed button
Timer operation
The timer can be preset to switch on or switch off the unit for a maximum of 12 hours. Each time one of the timer/temp adjust
buttons is pressed, the number of remaining hours is increased or decreased by an hour. The number of hours is shown on the
display.
How to set the unit to switch off automatically
1. While the unit is on press the timer button. The room temp button disappears and the on/off buttons will start blinking
2. Set the desired amount of time until the unit is switched off with the timer/temp adjust buttons
3. Keep in mind that after setting has been made, the room temp lights up again and the display will switch to show the
room temperature
After the set amount of time has elapsed, the unit switches off automatically. Whether or not the timer is activated is indicated
by the on/off display.