background image

EN

2

Operating manual – local air conditioner PAC 2000 SH

Ensure that all electric cables outside of the device are
protected from damage (e.g. caused by animals). Never
use the device if electric cables or the power connection
are damaged!

The electrical connection must correspond to the
specifications in chapter Technical data.

Insert the mains plug into a properly secured mains
socket.

Observe the technical data when selecting extensions to
the power cable. Completely unroll the extension cable.
Avoid electrical overload.

Before carrying out maintenance, care or repair work on
the device, remove the mains plug from the mains socket.
Hold onto the mains plug while doing so.

Switch the device off and disconnect the power cable from
the mains socket when the device is not in use.

Do not under any circumstances use the device if you
detect damages on the mains plug or power cable. 
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
Defective power cables pose a serious health risk.

When positioning the device, observe the minimum
distances from walls and other objects as well as the
storage and operating conditions specified in the Technical
data chapter.

Ensure that the air inlet and outlet are not obstructed.

Do not remove any safety signs, stickers or labels from the
device. Keep all safety signs, stickers and labels in legible
condition.

Ensure that the side of the device where the air inlet is
found is kept free of dirt and loose objects.

Only transport the device in an upright position with an
emptied condensation tray or drain hose.

Discharge the collected condensate before transport and
storage. Do not drink it. Health hazard!

Intended use

Only use the device for cooling, ventilating, dehumidifying and
heating indoor air whilst adhering to the technical data.

Improper use

Do not place the device on wet or flooded ground.

Do not place any objects, e.g. clothing, on the device.

Do not use the device outdoors.

Any unauthorised modifications, such as alterations or
structural changes to the device, are forbidden.

Any operation other than as described in this manual is
prohibited. Non-observance renders all claims for liability
and guarantee null and void.

Personnel qualifications

People who use this device must:

be aware of the dangers that occur when working with
electric devices in damp areas.

have read and understood the operating manual, especially
the Safety chapter.

Maintenance tasks which require the housing to be opened
must only be carried out by specialist companies for cooling and
air-conditioning or by Trotec.

Summary of Contents for PAC 2000 SH

Page 1: ...TRT BA PAC2000SH TC 002 EN PAC 2000 SH EN OPERATING MANUAL LOCAL AIR CONDITIONER...

Page 2: ...e device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may re...

Page 3: ...pecified in the Technical data chapter Ensure that the air inlet and outlet are not obstructed Do not remove any safety signs stickers or labels from the device Keep all safety signs stickers and labe...

Page 4: ...cable out of the mains socket 3 Do not reconnect a defective device to the mains Information about the device Device description The device serves the purpose of cooling the room air It further filter...

Page 5: ...Transport To make the device easier to transport it is fitted with wheels Before transporting the device observe the following Switch the device off Hold onto the mains plug while pulling the power c...

Page 6: ...device 1 Open the cardboard box and take the device out 2 Completely remove the packaging 3 Fully unwind the power cable Make sure that the power cable is not damaged and that you do not damage it dur...

Page 7: ...ce the dehumidification performance and result in damage to the device Make sure that the air filter is installed before switching the device on 900 Connecting the exhaust air hose 1 Connect the exhau...

Page 8: ...hift The end of the exhaust air hose can also be hooked into a tilted window For this purpose we recommend using a window seal optional Install the exhaust air hose inclined with the air direction Exa...

Page 9: ...ting mode Display of current room temperature Indication of the number of hours during timer programming Indication of the error code see chapter Errors and faults C F indication 16 Timer button Switc...

Page 10: ...annot be adjusted 1 Press the operating mode button 23 until the ventilation LED 24 is illuminated 2 Press the fan stage button 13 to set the desired fan stage The fan stage LED 12 for the desired fan...

Page 11: ...24 is illuminated The current room temperature is indicated on the segment display 15 2 Press the fan stage button 13 to set the desired fan stage The fan stage LED 12 for the desired fan stage will...

Page 12: ...Wait for 3 seconds to confirm the setting The number of hours until automatic switch off will be indicated on the segment display 15 for approx 3 s The timer LED 17 is illuminated Then the segment dis...

Page 13: ...or the timer 1 h to 24 h 23 Operating mode button Selecting the operating mode heating ventilation dehumidification cooling automatic operation Automatic defrost At low ambient temperatures ice may fo...

Page 14: ...for approx 10 minutes before reconnecting it Check whether the ambient temperature equals the target temperature in cooling mode The compressor will not switch on unless the respective temperature is...

Page 15: ...ry 6 months at least annually Check air inlets and outlets for dirt and foreign objects and clean if necessary X X Clean the exterior X X Visually check the inside of the device for dirt X X Check the...

Page 16: ...e device for dirt Check the air filter for dirt and foreign objects and clean or replace if necessary Replace the air filter Check for damage Check the attachment screws Test run Remarks Empty the con...

Page 17: ...ck the inside of the device for dirt 4 If you see a thick layer of dust have the inside of the device cleaned by a specialist company for cooling and air conditioning or by Trotec 5 Put the air filter...

Page 18: ...device switches off and indicates this via the E4 error code on the segment display 15 1 Carefully transport or wheel the device to a suitable location for discharging the condensate e g a drain or po...

Page 19: ...con with the crossed out waste bin on waste electrical or electronic equipment stipulates that this equipment must not be disposed of with the household waste at the end of its life You will find coll...

Page 20: ......

Page 21: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: