6
EN
radiant heater IR 2010 / IR 3010
Assembly and installation
Scope of delivery
IR 2010
•
1 x Device
•
1 x Mounting bracket
•
2 x Wing nut
•
3 x Screw
•
2 x Fastening screw
•
3 x Wall plug
•
1 x SW 5 Allen wrench
•
1 x Manual
IR 3010
•
1 x Device
•
2 x Mounting bracket
•
4 x Wing nut
•
6 x Screw
•
4 x Fastening screw
•
6 x Wall plug
•
1 x SW 5 Allen wrench
•
1 x Manual
Unpacking the device
1. Open the cardboard box and take the device out.
2. Completely remove the packaging.
3. Fully unwind the power cable. Make sure that the power
cable is not damaged and that you do not damage it during
unwinding.
Assembly
The device is only suited for wall mounting. Observe the
following requirement for installation inside a room:
Warning
Risk of fire due to improper installation!
There is a risk of fire if the required minimum
distances are not observed.
The device must be positioned at a distance of at least
180 cm from the floor and at least 50 cm from walls
and other objects such as curtains or sockets.
Installation
When installing the device, observe the minimum distances
from walls and other objects as described in the Technical data
chapter.
•
Minimum distance of 180 cm from the floor.
•
Minimum distance of 50 cm from adjacent walls or other
objects.
•
For installation in bathrooms or washing rooms, observe
the national regulations on safety distances.
•
Do not install the device at the ceiling or directly behind a
door.
•
Never install the device in a way that it radiates directly
onto walls or other objects.
•
Only install the device in a horizontal position.
180 cm
50 cm
50 cm
50 cm
The following is required for installation:
•
a pencil for marking the drill holes
•
a suitable drill
•
wall plugs appropriate for the structure of the wall
•
a screwdriver
•
a spirit level