![Trotec DH 15 Original Instructions Manual Download Page 9](http://html1.mh-extra.com/html/trotec/dh-15/dh-15_original-instructions-manual_1171785009.webp)
EN
9
dehumidifier DH 15 / DH 30 / DH 60
8. Check whether the condensation drain hose is positioned
correctly. The condensation drain hose must not be
kinked.
Ø = 11 mm
9. Put the housing back on the device.
Operation
•
After being switched on, the device operates fully
automatically.
•
To ensure that the built-in sensor can correctly detect the
humidity, the fan continues to operate until the device is
switched off.
•
Avoid open doors and windows.
Operating elements
5
8
No. Designation
Meaning
5
Control dial
For setting the desired humidity level
8
MODE
switch
For setting the desired operating mode:
CONT.
= fan runs permanently.
CYC.
= fan switches on and off along
with the compressor.