laser distance measuring device BD22

Twofold indirect height measurement

This method is suitable for e.g. height measurements when you
are not at the same height as the base point.
The measurement result is calculated by determining the
distances A, B and C.

A

B

C

1. Press the 

 button (13) until the 

 symbol for the

twofold indirect measurement appears on the display.

2. First, aim the device at the highest point (C) and briefly

press the Switch-on/measurement button (7) once to
perform a measurement. In doing so, hold the device as
steady as possible. 

The alignment of the device in

relation to the reference point must not be changed
during the measurements!

ð

The length of the line segment is displayed in the
"Indication of the measured value 1" (17).

3. Align the device horizontally (point B) and briefly press

the 

 button (7) one time to measure the horizontal

distance.

ð

The second measured value is displayed in the
"Indication of measured value 2" (18).

4. First, aim the device at the highest point (A) and briefly

press the 

 button once to perform a measurement.

ð

The third measured value is displayed in the "Indication
of measured value 3" (19).

ð

The line segment to be determined is displayed as result in
the lower measurement value display (20).

Indirect measurement of a partial height

This method is suitable for measuring partial heights (e.g. storey
heights, window heights, etc.).
The measurement result is calculated by determining the
distances A, B and C.

C

B

A

1. Press the 

 button (13) until the 

 symbol for the

indirect measurement of a partial height appears on the
display.

2. First, aim the device at the upper point (A) of the partial

height to be measured and briefly press the 

 button (7)

once to perform a measurement. Make sure to hold the
device as steady as possible. 

The alignment of the

device in relation to the reference point must not be
changed during the measurements!

ð

The length of the line segment is displayed in the
"Indication of the measured value 1" (17).

3. Now aim the device at the lowest point (B) of the partial

height to be measured and briefly press the 

 button (7)

once to perform a measurement.

ð

The second measured value is displayed in the
"Indication of measured value 2" (18).

4. Using the spirit level, align the device horizontally at the

lower measuring point (C) and briefly press the 

button

once to measure the horizontal distance.

ð

The third measured value is displayed in the "Indication
of measured value 3" (19).

ð

The partial height to be determined is displayed as result in
the lower measurement value display (20).

Summary of Contents for BD22

Page 1: ...TRT BA BD22 TC210826TTRT02 001 EN BD22 EN OPERATING MANUAL LASER DISTANCE MEASURING DEVICE ...

Page 2: ... id 45780 Safety Read this manual carefully before starting or using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference Do not use the device i...

Page 3: ...long in the hands of children Warning Dangers can occur at the device when it is used by untrained people in an unprofessional or improper way Observe the personnel qualifications Caution Keep a sufficient distance from heat sources Note To prevent damages to the device do not expose it to extreme temperatures extreme humidity or moisture Note Do not use abrasive cleaners or solvents to clean the ...

Page 4: ...t value in the history No Designation Function 13 button Press briefly change measuring mode Press for a long time enable or disable acoustic signal Display 28 26 14 15 16 17 18 19 20 21 22 23 24 25 MAX MIN 29 27 No Display element 14 Battery status 15 Area measurement Volume measurement 16 Trapezoidal measurement 17 Indication of measured value 1 incl unit 18 Indication of measured value 2 incl u...

Page 5: ...dry conditions and protect the device from external influences e g by using a suitable bag Storage When the device is not being used observe the following storage conditions dry and protected from frost and heat protected from dust and direct sunlight the storage temperature complies with the values specified in the Technical data Remove the batteries from the device Operation Inserting the batter...

Page 6: ...hrough the history and call up the saved measured values 3 Press the button 9 for a long time to delete the saved measured values 4 Briefly press the button the button 13 or the C Off button 10 to return to the measuring menu Press the Unit button 11 to return to the pin dimension measuring mode Briefly press the C Off button 10 to return to the laser measuring mode Info It is not possible to save...

Page 7: ...d value for a distance e g a measurement from a ground plan A 1 531m 1 Press the button 7 for a long time ð With activated signal indication function a recurring acoustic signal is emitted ð The maximum minimum and current value are indicated on the display 2 Depending on the desired measurement move the device slowly back and forth or up and down e g in the corner of a room 3 Briefly press the bu...

Page 8: ... measurement Pythagoras Using this method the length of an unknown straight line segment can be determined via the Pythagorean Theorem This method is suitable for e g height measurements The measurement result is calculated by determining the distances A and B A B 1 Press the button 13 until the symbol for the indirect measurement appears on the display ð The upper bar hypotenuse flashes 2 First a...

Page 9: ...etermined is displayed as result in the lower measurement value display 20 Indirect measurement of a partial height This method is suitable for measuring partial heights e g storey heights window heights etc The measurement result is calculated by determining the distances A B and C C B A 1 Press the button 13 until the symbol for the indirect measurement of a partial height appears on the display...

Page 10: ...building To do so please proceed as follows 1 Press the button 13 until the number 10 and the symbol for the timer 27 appear on the display 2 Use the 12 and buttons 9 to set the delay time between 5 and 60 s 3 Position the device in a way that it is firmly placed on the ground and that measurements up to the desired point e g horizontally can be performed 4 Briefly press the button 7 to activate t...

Page 11: ... proper functioning several times during production If malfunctions occur nonetheless check the device according to the following list The following fault indications can appear in the lower measurement value display Display Cause Remedy 203 The temperature is too high Allow the device to cool down Observe the permissible operating temperature according to the Technical data chapter 220 The batter...

Page 12: ... contact an official recycling centre for electronic and electrical equipment authorised for your country The separate collection of waste electrical and electronic equipment aims to enable the re use recycling and other forms of recovery of waste equipment as well as to prevent negative effects for the environment and human health caused by the disposal of hazardous substances potentially contain...

Page 13: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Reviews: