background image

EN

9

humidifier B 7 E

Night mode

The control element's sound output is deactivated during night
mode. The display switches off after approx. 40 s and only
switches back on when a button is pressed.

ü

The device is switched on.

1. Press the 

night mode

 button (

23

) to activate the night

mode.

ð

The 

night mode

 indication (

25

) appears on the display.

ð

Night mode is now activated.

2. Press the 

night mode

 button (

23

) again to activate the

night mode.

Timer function

The 

timer

 can be programmed in order to switch the device on

or off after a preset number of hours (1 to max. 12). The 

timer

can be programmed in increments of 1 hour.

Automatic switch-off

Please proceed as follows to programme automatic switch-off:

ü

The device is switched on.

1. Press the 

timer

 button (

20

) until the desired number of

hours is displayed.

2. Wait a moment until the number of hours stops flashing.

ð

The 

timer

 setting equals the desired number of hours.

ð

The current room humidity is displayed again.

ð

The device switches off after the set period of time.

Notes regarding automatic switch-off:

Pressing the On/off button (

22

) deactivates the automatic

switch-off function.

Automatic switch-on

Please proceed as follows to programme automatic switch-on:

ü

The device is now in standby mode.

1. Press the 

timer

 button (

20

) until the desired number of

hours is displayed.

2. Wait a moment until the number of hours stops flashing.

ð

The 

timer

 setting equals the desired number of hours.

ð

The display switches off after a few seconds.

ð

The device switches on after the selected time has
elapsed.

Notes regarding automatic switch-on:

Pressing the On/off button (

22

) deactivates the automatic

switch-on function.

Shutdown

Warning of electrical voltage

Do not touch the mains plug with wet or damp hands.

Switch the device off.

Hold onto the mains plug while pulling the power cable out
of the mains socket.

Empty the water tank.

Empty the lower part.

Use a cloth to wipe all parts of the device dry.

Clean the device according to the Maintenance chapter.

Store the device according to the Transport and storage
chapter.

Available accessories

Warning

Only use accessories and additional equipment
specified in the operating manual.
Using insertion tools or accessories other than those
specified in the operating manual may cause a risk of
injury.

Designation

Article number

SecoSan

®

 Stick 10

6.100.004.110

Summary of Contents for B7E

Page 1: ...TRT BA B7E TC2021 19 002 EN B 7 E EN OPERATING MANUAL HUMIDIFIER ...

Page 2: ...f the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience ...

Page 3: ...cannot be reduced the device must only be operated in intervals If necessary switch the device off completely for a short time Absorbent materials such as carpeting curtains sheers or tablecloths must not become damp Make sure that the water in the water thank is replaced every 3 days Otherwise there is a risk of microorganisms growing in the water tank which presents a health hazard if they get i...

Page 4: ...to the air inlet Without the air filter the inside of the device will be heavily contaminated This could reduce the performance and result in damage to the device Behaviour in the event of an emergency 1 Switch the device off 2 In an emergency disconnect the device from the mains feed in Hold onto the mains plug while pulling the power cable out of the mains socket 3 Do not reconnect a defective d...

Page 5: ...tore or transport the device improperly the device may be damaged Note the information regarding transport and storage of the device Transport Before transporting the device observe the following Switch the device off Hold onto the mains plug while pulling the power cable out of the mains socket Lift the device at the lower part Empty the water tank Empty the lower part Do not use the power cable ...

Page 6: ... Start up Before restarting the device check the condition of the power cable If there are doubts as to the sound condition contact the customer service Only put up the device in an upright stable position on firm ground Do not create tripping hazards when laying the power cable or other electric cables especially when positioning the device in the middle of the room Use cable bridges Make sure th...

Page 7: ...Remove the cover of the carbon filter 6 with the integrated scented oil tank 15 from the device 2 Put 2 to 3 drops of scented oil onto the sponge in the scented oil tank 15 15 6 Inserting the air filter Note Do not operate the device without an air filter inserted into the air inlet Without the air filter the inside of the device will be heavily contaminated This could reduce the performance and r...

Page 8: ...s the On off switch 22 ð The segment display 17 indicates the last selected nebulizer intensity ð The device starts to humidify Fine water mist leaves the mist nozzle 2 ð During manual humidification the device indicates the current relative humidity on the segment display in percent Setting the nebulizer intensity Info If no operational input is made for 40 s the segment display 17 switches off T...

Page 9: ... off button 22 deactivates the automatic switch off function Automatic switch on Please proceed as follows to programme automatic switch on ü The device is now in standby mode 1 Press the timer button 20 until the desired number of hours is displayed 2 Wait a moment until the number of hours stops flashing ð The timer setting equals the desired number of hours ð The display switches off after a fe...

Page 10: ... freely Clean the water tank if required Water is leaking Check whether the device is set up in a stable and upright position Check the water level in the lower part of the device The water level might be too high and water is discharged via the overflow Check the valve in the water tank lid The valve must be able to move freely Clean the water tank if required Check the float in the lower part of...

Page 11: ...ent screws X X Test run X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Cleaning the water tank Check air inlets and outlets for dirt and foreign objects and clean if necessary Clean the exterior Visually check the inside of the device for dirt Check the air filter for dirt and foreign objects and clean or replace if necessa...

Page 12: ...s of silver ions Due to the special antimicrobial surface the silver ions are emitted to the immediate proximity of bacteria and germs This way microbial growth can be effectively prevented at the same time the water remains pure and uncontaminated The dosage of the SecoSan Stick is carried out automatically Info Clean the nebulizer membrane air outlet water tank and the water lines as often as po...

Page 13: ...ling agent 4 Let the descaling agent act for approx 2 to 5 min 5 Remove the deposits from the nebulizer membrane 10 using the cotton bud 10 6 Rinse the inside of the device with clear water 7 Refit the water tank 3 as described in Cleaning the water tank Cleaning the air filter The air filter should be cleaned or replaced in case of heavy soiling 1 Lightly push against the cover of the carbon filt...

Page 14: ...is tank is integrated in the cover of the carbon filter 1 Lightly push against the cover of the carbon filter 6 so that the cover is unlocked from the housing 2 Carefully remove the cover of the carbon filter 6 from the device 3 Now clean the area around the scented oil tank 15 6 15 4 Use a cloth to wipe the scented oil tank 15 dry 5 Slide the cover of the carbon filter 6 into the bottom section 4...

Page 15: ...quipment must not be disposed of with the household waste at the end of its life You will find collection points for free return of waste electrical and electronic equipment in your vicinity The addresses can be obtained from your municipality or local administration You can also find out about other return options that apply for many EU countries on the website https hub trotec com id 45090 Other...

Page 16: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...