Operating manual – humidifier B 1 E

Cleaning the nebulizer membrane

Depending on the hardness of the drinking water used, deposits
may form on the nebulizer membrane over time. These could
affect the nebulizer performance. Therefore, the nebulizer
membrane should be cleaned on a regular basis.
To do so, please proceed as follows:

1. Remove the water tank (1) as described in 

Cleaning the

water tank

.

2. Remove any residual water from the inside of the device.
3. Wet the nebulizer membrane (12) with a conventional

descaling agent (e.g. household vinegar).

4. Let the descaling agent act for approx. 2 to 5 min.
5. Remove the deposits from the nebulizer membrane (12)

using the brush (8).

12

8

6. Rinse the inside of the device with clear water.
7. Refit the water tank (1) as described in 

Cleaning the water

tank

.

Regenerating the water softener

Depending on the hardness of the water, the water softener
must be regenerated approx. once per month.
To do so, please proceed as follows:

1. Remove the water tank (1) as described in 

Cleaning the

water tank

.

2. Unscrew the lid (11) from the water tank (1).

11

6

3. Unscrew the filter cartridge (6) from the lid (11).
4. Provide a vessel containing saturated saline solution.
5. Place the filter cartridge into the vessel containing saline

solution. Make sure that the filter cartridge is completely
covered by the saline solution.

6. Leave the filter cartridge in the saline solution for 24 h.
7. Take the filter cartridge out of the saline solution after

24 h.

8. Rinse the filter cartridge with clear water.
9. Screw the filter cartridge (6) back onto the lid (11).

6

10. Screw the lid (11) firmly back onto the water tank (1).
11. Refit the water tank (1) as described in 

Cleaning the water

tank

.

Summary of Contents for B 1 E

Page 1: ...TRT BA B1E TC 002 EN B 1 E EN OPERATING MANUAL HUMIDIFIER ...

Page 2: ...of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience...

Page 3: ...Do not use the device outdoors Any unauthorised modifications alterations or structural changes to the device are forbidden Any operation other than as described in this manual is prohibited Non observance renders all claims for liability and guarantee null and void Personnel qualifications People who use this device must be aware of the dangers that occur when working with electric devices in dam...

Page 4: ...on the water tank can be additionally illuminated by blue LEDs located in the lower part of the device The device switches off automatically when the water tank is empty Device depiction 1 2 9a 3 10 9b 4 5 6 8 7 No Designation 1 Top with water tank 2 Bottom section 3 Carbon filter 4 Filling level indication 5 Scented oil tank with sponge 6 Filter cartridge with water softener 7 SecoSan Stick 10 op...

Page 5: ...sembly and installation Scope of delivery 1 x Device 1 x Water softener 1 x Brush 1 x Manual Unpacking the device 1 Open the cardboard box and take the device out 2 Completely remove the packaging 3 Fully unwind the power cable Make sure that the power cable is not damaged and that you do not damage it during unwinding Start up Before restarting the device check the condition of the power cable If...

Page 6: ...tank over 3 Unscrew the lid 11 from the water tank 1 11 6 4 Fill fresh drinking water approx 3 l maximally 40 C into the water tank 5 Insert the SecoSan Stick optional accessory into the water tank 6 Screw the lid 11 firmly back onto the water tank 1 6 7 Place the top correctly onto the bottom section ð Please note that after inserting the water tank the water immediately starts to run into the bo...

Page 7: ...disconnected from the mains 1 Remove the scented oil tank 5 from the device 5 2 Put 2 to 3 drops of scented oil onto the sponge in the scented oil tank 5 3 Push the scented oil tank 5 back into the device Inserting the air filter Notice Do not operate the device without an inserted air filter Without the air filter the inside of the device will be heavily contaminated This could reduce the perform...

Page 8: ...ensity Switching illumination on or off When the device is in operation the water tank can be additionally illuminated by two blue LEDs located in the device bottom 1 Press the on off switch 9a to switch the illumination on or off Shutdown Warning of electrical voltage Do not touch the mains plug with wet or damp hands Switch the device off by pressing the on off switch 9a for approx 2 s Hold onto...

Page 9: ...level might be too high and water is discharged via the overflow Check the valve in the water tank lid The valve must be able to move freely If necessary clean the water tank Check the float in the lower part of the device The float should be able to move freely It may block and cause water to be discharged via the overflow Check the device for leaks The water mist has a peculiar smell The device ...

Page 10: ...he water tank with a conventional descaling agent e g household vinegar 7 Thoroughly rinse the water tank and the SecoSan Stick with clear water 8 Allow the water tank to dry 9 Clean the inside of the bottom section and the mist nozzle with a conventional descaling agent e g household vinegar and then use a lint free cloth to wipe the parts dry For cleaning the nebulizer membrane see chapter Clean...

Page 11: ...ter tank 1 as described in Cleaning the water tank Regenerating the water softener Depending on the hardness of the water the water softener must be regenerated approx once per month To do so please proceed as follows 1 Remove the water tank 1 as described in Cleaning the water tank 2 Unscrew the lid 11 from the water tank 1 11 6 3 Unscrew the filter cartridge 6 from the lid 11 4 Provide a vessel ...

Page 12: ...rn or damaged The corners and edges of the air filter must not be deformed or rounded Before reinserting the air filter make sure that it is undamaged and dry The air filter has to be cleaned as soon as it is dirty This is brought to light e g by a reduced capacity see chapter Errors and faults 1 Remove the air filter from the device 2 Rinse the filter with warm water 3 Allow the filter to dry com...

Page 13: ...quipment stipulates that this equipment must not be disposed of with the household waste at the end of its life You will find collection points for free return of waste electrical and electronic equipment in your vicinity The addresses can be obtained from your municipality or local administration For further return options provided by us please refer to our website www trotec24 com The separate c...

Page 14: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Reviews: