air cleaner AirgoClean® 200 E

Maintenance

Maintenance intervals

Maintenance and care interval

before every
start-up

as needed

at least every
2 weeks

at least every
4 weeks

at least every
6 months

at least
annually

Check air inlets and outlets for dirt
and foreign objects and clean
if necessary

X

X

Clean the exterior

X

X

Visually check the inside of the
device for dirt

X

X

Check the filter for dirt and foreign
objects and clean or replace if
necessary

X

X

Clean the prefilter

X

Replace the filter

X

Check for damage

X

Check the attachment screws

X

X

Test run

X

Maintenance and care log

Device type: .............................................

Device number: ....................................

Maintenance and care interval

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

Check air inlets and outlets for dirt
and foreign objects and clean
if necessary

Clean the exterior

Visually check the inside of the
device for dirt

Check the filter for dirt and foreign
objects and clean or replace if
necessary

Clean the prefilter

Replace the filter

Check for damage

Check the attachment screws

Test run

1. Date:  ...................................
Signature: ................................

2. Date:  ....................................
Signature: .................................

3. Date:  ....................................
Signature: .................................

4. Date:  ....................................
Signature: .................................

5. Date:  ...................................
Signature: ................................

6. Date:  ....................................
Signature: .................................

7. Date:  ....................................
Signature: .................................

8. Date:  ....................................
Signature: .................................

9. Date:  ...................................
Signature: ................................

10. Date:  ..................................
Signature: .................................

11. Date:  ..................................
Signature: .................................

12. Date:  ..................................
Signature: .................................

13. Date:  .................................
Signature: ................................

14. Date:  ..................................
Signature: .................................

15. Date:  ..................................
Signature: .................................

16. Date:  ..................................
Signature: .................................

Summary of Contents for AIRGOCLEAN 200 E

Page 1: ...TRT BA AIRGOCLEAN 200E TC2020 53 004 EN AIRGOCLEAN 200 E EN OPERATING MANUAL AIR CLEANER...

Page 2: ...e manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock f...

Page 3: ...ed Make sure that there are no loose items or dirt located in the immediate surroundings of air inlet and air outlet Do not remove any safety signs stickers or labels from the device Keep all safety s...

Page 4: ...tion about the device Device description The device serves to filter the room air with the aim of reducing slight and medium contaminations and odours in order to improve the air quality It is equippe...

Page 5: ...rry handle To make the device easier to transport it is fitted with wheels Before transporting the device observe the following Switch the device off Hold onto the mains plug while pulling the power c...

Page 6: ...as described in the chapter Technical annex A B C C D Before restarting the device check the condition of the power cable If there are doubts as to the sound condition contact the customer service On...

Page 7: ...y LED Is illuminated according to the air quality blue good orange medium red poor 18 HEPA carbon filter LED If the Replace indication is illuminated and the last bar of the LED is illuminated in red...

Page 8: ...OC organic chemical compounds The device cannot determine the virus load inside the room It is possible that the automatic mode indicates a good air quality even though the virus load in the room is v...

Page 9: ...15 for 3 seconds again to deactivate the function The device switches back to the previous operating mode Memory function If you switch the device back on from standby mode the settings selected for...

Page 10: ...them The HEPA carbon filter is not installed Install the HEPA carbon filter Check the minimum distance to walls or other objects Position the device a little more in the room s centre if required The...

Page 11: ...t screws X X Test run X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign object...

Page 12: ...openings of the device 3 Check the inside of the device for dirt 4 If you see a thick layer of dust clean the inside of the device with a vacuum cleaner 5 Reinsert the air filters Changing the HEPA ca...

Page 13: ...se of the HEPA carbon filter according to the national regulations 6 Take the new HEPA carbon filter out of the plastic cover 7 Insert the new HEPA carbon filter into the device Make sure that the str...

Page 14: ...3 h Ambient temperature 10 C to 45 C Operating range 0 to 95 RH Mains connection 220 240 V 50 Hz Power consumption 38 W Nominal current 0 17 A Sound pressure level 54 dB A Dimensions length x width x...

Page 15: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: