submerged clear water pump, near-ground suction TWP 4005 E / TWP 7505 E / TWP 9005 E

General safety

Do not use the device in potentially explosive rooms or
areas and do not install it there.

Do not use the device in aggressive atmosphere.

Check accessories and connection parts for possible
damage prior to every use of the device. Do not use any
defective devices or device parts.

Before carrying out maintenance, care or repair work on
the device, remove the mains plug from the mains socket.
Hold onto the mains plug while doing so.

When positioning the device, observe the minimum
distances from walls and other objects as well as the
storage and operating conditions specified in the Technical
annex.

Do not remove any safety signs, stickers or labels from the
device. Keep all safety signs, stickers and labels in legible
condition.

General safety warnings – Electrical safety

The device is to be supplied with a rated residual current
of no more than 30 mA by means of an RCD (Residual
Current protective Device).

Ensure that all electric cables outside of the device are
protected from damage (e.g. caused by animals). Never
use the device if electric cables or the power connection
are damaged!

The mains connection must correspond to the
specifications in the Technical annex.

Insert the mains plug into a properly fused mains socket.

Switch the device off and disconnect the power cable from
the mains socket when the device is not in use.

Do not under any circumstances use the device if you
detect damages on the mains plug or power cable. 
If the connection line of this device is damaged, the device
must be sent for recycling in accordance with the
specifications provided in the Disposal chapter.
Defective power cables pose a serious health risk!

Should there be a risk of flooding, install the plug
connections in a flood-proof area. 

There is a risk of

electric shock!

Make sure that the mains voltage corresponds to the
specifications on the nameplate.

Have all electrical installations carried out by an expert
according to the national regulations and the device-
specific requirements.

Do not use the power cable to drag the device.

Hold onto the mains plug while pulling the power cable out
of the mains socket.

Protect the power supply cable against heat, oil and sharp
edges. Make sure that the power supply cable is not
crushed, kinked or subjected to other mechanical stresses.

Only use splash-proof extension cables intended for
outdoor use whilst observing the device's power input.
Before using cable drums, always unroll the cable
completely. Check the cable for damage. The use of
extension cables which are not approved for outdoor use
can result in injuries due to electric shock.

Before performing any work on the device, in case of leaks
in the water system, before taking work breaks or when
not in use, remove the mains plug from the mains socket.

General safety warnings – Personal safety

Never use the device with persons or animals in the water
or pumping medium or if they could access it. 

There is a

risk of electric shock!

Never insert any objects or limbs into the device.

This appliance is not a toy. Keep away from children and
animals. Do not leave the device unattended during
operation.

Device-specific safety warnings for submerged
pumps

Do not leave the device running unattended to ensure an
early detection of when the device runs dry or switches off
automatically. This would damage the device. Regularly
check the float for proper functioning.

Please bear in mind, that the device is not suitable for
continuous operation (e.g. for watercourses in garden
ponds). Check the device for proper functioning on a
regular basis.

Keep in mind, that lubricants are used within the device.
These might potentially cause damages or contaminations
if emitted. Do not use the device for drinking water or in
garden ponds with either a fish population or valuable
plants.

The device is not to be carried by holding it at the power
supply cable or hose. Do not fasten it there either.

Do not place any objects on the device – not even to
weight it down. The device will sink to the ground due to
its own weight.

After the set-up of the device, its mains plug must be
readily accessible during operation.

Wear sturdy shoes to protect yourself against electric
shock.

Provide appropriate frost protection.

Summary of Contents for 4610000005

Page 1: ...TRT BA TWP4005E TWP7505E TWP9005E TC211020TTRT02 005 EN TWP 4005 E TWP 7505 E TWP 9005 E EN OPERATING MANUAL SUBMERGED CLEAR WATER PUMP NEAR GROUND SUCTION...

Page 2: ...ow the manual Information marked with this symbol indicates that the operating manual must be observed You can download the current version of the operating manual and the EU declaration of conformity...

Page 3: ...ns and the device specific requirements Do not use the power cable to drag the device Hold onto the mains plug while pulling the power cable out of the mains socket Protect the power supply cable agai...

Page 4: ...continuous operation e g as recirculation pump for ponds The device is not suitable for use as a filter pump in swimming pools and the like The device is not suitable as permanent automatic overflow...

Page 5: ...not in use Not suitable for pumping potable water This symbol indicates that the device is not suitable for pumping potable water Submerge pump at a slight angle This symbol indicates that the pump mu...

Page 6: ...e switch on off height can be finely adjusted within the specified range by means of a locking device see technical data The water temperature must not exceed 35 C Info The illustrations in this opera...

Page 7: ...th seal preassembled 1 x Retainer for backflow preventer 1 x Seal ring 1 x Elbow 1 x Nylon cord 12 m 1 x Manual Unpacking the device 1 Open the cardboard box and take the device out 2 Completely remov...

Page 8: ...the hose 6 Push the hose inner diameter 25 mm or 32 mm onto the reducer 7 all the way to the stop 7 Affix the hose by means of the hose clamp 8 When using a hose with internal thread 1 Screw the hose...

Page 9: ...sition by pushing the cable into the float switch locking device 3 at the side of the pump 4 3 Installing the device Please observe the following information regarding the device set up and before swi...

Page 10: ...d above the adjusted or the maximum switch on height The device will be switched off as soon as the float switch reaches the set or the minimum switch off height Info The device comes equipped with a...

Page 11: ...ice has been checked for proper functioning several times during production If malfunctions occur nonetheless check the device according to the following list The device does not start Check the power...

Page 12: ...e delivery head paired with a small hose diameter can cause a reduction of the conveying capacity Check whether the hose line is kinked or blocked Remove kinks and or blockages Note Wait for at least...

Page 13: ...240 V 50 Hz 230 V 240 V 50 Hz Power consumption 400 W 750 W 900 W Protection type IPX8 IPX8 IPX8 Minimum operating depth 80 mm 80 mm 80 mm Max water level after suction 3 mm 3 mm 3 mm Connection type...

Page 14: ...C 18 cm max 7 5 m max 7 m 42 cm TWP 7505 E max 35 C 18 cm max 10 m max 7 m 60 cm TWP 9005 E max 35 C 18 cm max 11 5 m max 7 m 60 cm Performance chart delivery head flow rate TWP 4005 E 9 000 6 000 3...

Page 15: ...ained from your municipality or local administration You can also find out about other return options that apply for many EU countries on the website https hub trotec com id 45090 Otherwise please con...