Trotec 3510205090 Operating Manual Download Page 5

EN

4

HCHO/TVOC measuring device BQ16

Display

HOLD MAX MIN

HCHO

TVOC

PPM

mg/m

³

PPM

mg/m

³

14

15

16

9

10

11

12

13

No.

Designation

9

Battery indication

10

Indication for automatic switch-off

11

HOLD

 indication

12

MAX

 indication

13

MIN

 indication

14

PPM / mg/m

3

 indication

15

TVOC measured value display

16

HCHO measured value display

Technical data

Parameter

Value

Model

BQ16

Dimensions 
(length x width x height)

230 mm x 55 mm x 35 mm

Weight

205 g

HCHO (formaldehyde)

Measuring range

0.00 to 5.00 PPM
0.00 to 5.00 mg/m

3

Resolution

0.01 PPM
0.01 mg/m

3

Accuracy

±5 % FS*

TVOC (volatile organic compounds)

Measuring range

0.00 to 9.99 PPM
0.00 to 9.99 mg/m

3

Resolution

0.01 PPM
0.01 mg/m

3

Accuracy

±10 % FS*

Operating conditions

0 °C to +50 °C 
with < 80 % RH

Storage conditions

-10 °C to +60 °C 
with < 80 % RH

Display

Backlit LCD display

Battery

9 V battery

Automatic switch-off

15 min if automatic switch-off
is activated

* FS = full scale (in relation to the full scale value)

Scope of delivery

1 x HCHO/TVOC measuring device 

BQ16

1 x 9 V battery

1 x Quick guide

1 x Device bag

Summary of Contents for 3510205090

Page 1: ...TRT BA BQ16 TC 002 EN BQ16 EN OPERATING MANUAL HCHO TVOC MEASURING DEVICE ...

Page 2: ...e Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have bee...

Page 3: ...ing device comes equipped with a selectable display illumination When not in use an automatic switch off saves the battery Examples for formaldehyde concentration in the air Formaldehyde is a colourless gas which is often contained in the room air Depending on the personal sensitivity it is perceived as a pungent odour above certain concentrations Formaldehyde also referred to as HCHO or methanal ...

Page 4: ...y indicative Even below the thresholds of an acute individual effect TVOCs can affect the human well being and health through so called combination effects A long term exposure to even low TVOC concentrations particularly to mixtures can lead to unspecific symptoms and reactions including perception of unpleasant odours and tastes runny nose and watery eyes irritation of eyes nose throat dry mucou...

Page 5: ... x 35 mm Weight 205 g HCHO formaldehyde Measuring range 0 00 to 5 00 PPM 0 00 to 5 00 mg m3 Resolution 0 01 PPM 0 01 mg m3 Accuracy 5 FS TVOC volatile organic compounds Measuring range 0 00 to 9 99 PPM 0 00 to 9 99 mg m3 Resolution 0 01 PPM 0 01 mg m3 Accuracy 10 FS Operating conditions 0 C to 50 C with 80 RH Storage conditions 10 C to 60 C with 80 RH Display Backlit LCD display Battery 9 V batter...

Page 6: ...e measurement In this case the display shows either no measured values or they are incorrect Wait a few minutes until the device has become adjusted to the changed conditions before carrying out a measurement 1 Take the device out of the packaging so that it can adapt to the climatic and chemical ambient conditions This way the measurement is not affected by substances possibly contained in the pa...

Page 7: ...ice can no longer be switched on see chapter Inserting the battery Cleaning Clean the device with a soft damp and lint free cloth Ensure that no moisture enters the housing Do not use any sprays solvents alcohol based cleaning agents or abrasive cleaners but only clean water to moisten the cloth Repair Do not modify the device or install any spare parts For repairs or device testing contact the ma...

Page 8: ......

Page 9: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...