![Trotec 1510003001 Original Instructions Manual Download Page 10](http://html.mh-extra.com/html/trotec/1510003001/1510003001_original-instructions-manual_1171958010.webp)
10
EN
radial fan TFV PRO 1
Cleaning the air filter
The air filter should be cleaned prior to every use.
Note
Ensure that the air filter is not worn or damaged. The
corners and edges of the air filter must not be
deformed or rounded. Before reinserting the air filter,
make sure that it is undamaged and dry!
1. Remove the air filter from the device.
2. Clean the filter using a slightly damp, soft, lint-free cloth.
If the filter is heavily contaminated, clean it with warm
water mixed with a neutral cleaning agent.
3. Allow the filter to dry completely. Do not insert a wet filter
into the device!
4. Reinsert the air filter into the device. Make sure to slide the
air filter into the lower guide rail.
Technical annex
Technical data
Parameter
Value
Model
TFV PRO 1
Article number
1.510.003.001
Air volume
(max. stage, freely blowing)
1,250 m³/h
Air pressure (max. stage)
1,050 Pa
Fan stages
Infinitely variable
Mains connection
1/N/PE~ 230 V / 50 Hz
Power consumption
170 W
Sound pressure level
(distance 1.5 m)
73 dB(A)
Weight
6.0 kg
Dimensions
(length x width x height)
355 mm x 430 mm x 235 mm