background image

TRT-BA-TFVPRO1-TC2016-20-006-EN

TFV PRO 1

EN

ORIGINAL INSTRUCTIONS

RADIAL FAN

Summary of Contents for 1510003001

Page 1: ...TRT BA TFVPRO1 TC2016 20 006 EN TFV PRO 1 EN ORIGINAL INSTRUCTIONS RADIAL FAN ...

Page 2: ...e vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of...

Page 3: ...o use this device must have read and understood the instructions especially the Safety chapter Residual risks Warning of electrical voltage Work on the electrical components must only be carried out by an authorised specialist company Warning Dangers can occur at the device when it is used by untrained people in an unprofessional or improper way Observe the personnel qualifications Warning The dev...

Page 4: ...t small non marking 9 Air outlet 10 Transport handle Transport and storage Note If you store or transport the device improperly the device may be damaged Note the information regarding transport and storage of the device Transport To make the device easier to transport it is fitted with a carry handle Storage Before storing the device proceed as follows Switch off the device Hold onto the mains pl...

Page 5: ...ing the power cable or other electric cables especially when positioning the device in the middle of the room Use cable bridges Make sure that extension cables are completely unrolled Make sure that no curtains or other objects interfere with the air flow Inserting the air filter Caution Risk of injury from parts being whirled up Before switching the device on make sure that there are no loose par...

Page 6: ...e two screws Connecting a hose optional You can fit hoses to all connectors of the optionally available adapter plate Connectors which are not used should be closed with the suitable sealing caps to avoid weakening the air current The adapter plate for 3 connectors is used as an example in the following The hoses for the adapter plates with 8 or 12 connectors are connected in the same way In order...

Page 7: ...1 2 Wait until the fan has come to a standstill 3 Remove the mains plug from the mains socket 4 Clean the device according to the Maintenance chapter 5 Store the device according to the Storage chapter Available accessories Warning Only use accessories and additional equipment specified in the operating manual Using insertion tools or accessories other than those specified in the operating manual ...

Page 8: ...sary clean or replace the air filter The motor or fan is noisy or runs unevenly The fan is soiled Clean the fan according to the Maintenance chapter The fan is damaged If so contact Trotec or a specialist electrical company The motor bearing might be damaged If so contact Trotec or a specialist electrical company The fan produces grinding noises The fan blades are dirty or foreign objects are loca...

Page 9: ...components from moisture Do not use any aggressive cleaning agents such as cleaning sprays solvents alcohol based or abrasive cleaners to dampen the cloth Cleaning the fan If the fan runs unevenly or produces grinding noises it should be cleaned Should the problems persist after cleaning contact Trotec or a specialist electrical company 1 Open the upper cover of the housing by loosening the attach...

Page 10: ...ontaminated clean it with warm water mixed with a neutral cleaning agent 3 Allow the filter to dry completely Do not insert a wet filter into the device 4 Reinsert the air filter into the device Make sure to slide the air filter into the lower guide rail Technical annex Technical data Parameter Value Model TFV PRO 1 Article number 1 510 003 001 Air volume max stage freely blowing 1 250 m h Air pre...

Page 11: ... 1 L 5 4 N 10K R1 h kWh P1 LinLout N M1 DC out E1 GND L1 N PE Aderfarben wire colors sw schwarz black rt rot red ge gelb yellow gnge gruen gelb green yellow Gehäuse housing 230V AC 50 60Hz HW66 Kombizähler L in L out N BL GE RT SW BL GNGE bl blau blue ...

Page 12: ... declaration of conformity The signed declaration of conformity can be found at https hub trotec com id 39587 Declaration of conformity in accordance with the EC Machinery Directive 2006 42 EC Annex II Part 1 Section A Herewith we Trotec GmbH declare that the machinery designated below was developed constructed and produced in compliance with the requirements of the EC Machinery Directive in the v...

Page 13: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Reviews: