Trotec 1210002004 Operating Manual Download Page 2

1

Operating manual – Local air conditioner PAC 2000 E

EN

Symbols

Hazardous electric current!

Warns about hazards from electric current which can
lead to injuries or even death.

Danger!

Warns of a hazard which can lead to personal injury.

Caution!

Warns of a hazard which can lead to property damage.

The current version of the operating manual can be found at:

Legal notice

This release replaces all previous versions. No part of this
publication may be reproduced without written permission from
Trotec. The same applies for electronically processing,
duplicating or spreading the publication. Subject to technical
changes. All rights reserved. Trademarks are used without
guarantee that they may be used freely and primarily following
the spelling of the manufacturer. Product names are registered.
Changes to construction in the interests of constant
improvements to the product, as well as changes to the shape
and colour are reserved.
The scope of delivery may vary from product images. This
document was created with all due care. Trotec accepts no
liability whatsoever for possible mistakes or omissions.
© Trotec

Warranty and liability

The device complies with the fundamental health and safety
requirements of the applicable EU regulations and was tested at
the factory for perfect functionality multiple times. However, if
faults in the functionality occur and cannot be remedied with the
measures in the Errors and faults chapter, please get in touch
with your dealer or distributor. When making a warranty claim,
supply the device number (see the rear of the device). When
manufacturer's instructions or legal regulations have not been
followed, or after unauthorised changes to the device are made,
the manufacturer is not responsible for the resulting damages.
Changes to the device or unauthorised replacement of individual
parts can drastically impact the electrical safety of this product
and will result in the loss of the warranty. Liability does not extend
to damages to people or property caused by the device being
used other than as described in the instructions in this operating
manual. Subject to changes to technical design and model
changes as part of constant development and product
improvement without prior notice.
No liability is accepted for damages resulting from improper use.
In such a case, any warranty claims will be voided also.

Table of contents

Notes regarding the operating manual .................................... 1
Safety ..................................................................................... 2
Information about the device................................................... 3
Transport and storage............................................................. 4
Set-up and installation 
............................................................ 4
Start-up 
.................................................................................. 4
Operation................................................................................ 6
Errors and faults ..................................................................... 8
Maintenance ........................................................................... 11
Technical annex...................................................................... 12

Notes regarding the operating manual

PAC 2000 E

http://hub.trotec.com/?id=39643

Summary of Contents for 1210002004

Page 1: ...PAC 2000 E OPERATING MANUAL LOCAL AIR CONDITIONER EN TRT BA PAC2000E TC 004 EN...

Page 2: ...gulations and was tested at the factory for perfect functionality multiple times However if faults in the functionality occur and cannot be remedied with the measures in the Errors and faults chapter...

Page 3: ...g the device from the mains before starting with maintenance service or repair work Intended use Only use the air conditioner PAC 2000 E for cooling ventilating and dehumidifying room air indoors whil...

Page 4: ...1 The device was designed for universal and flexible application Due to its compact dimensions it can be easily transported and used in all interior spaces The air conditioner cools the room air by wi...

Page 5: ...ositioning the device observe the minimum distances from walls and other objects stated on the product data sheet Set the device up in a level upright and stable position Do not create tripping hazard...

Page 6: ...ose see fig B 3 Attach the sealed condensation hose to the condensate outlet see fig C 4 Affix the condensation hose by means of the hose clip and snap it into the retaining clip see fig C Discharging...

Page 7: ...utton 23 until the DEHUMDIFICATION mode indication 18 lights up VENTILATION mode FAN The device circulates the room air but there is no cooling A target temperature cannot be set the plus 21 and minus...

Page 8: ...various values and settings of the device 25 MODE button Setting the operating mode COOLING COOL DEHUMIDIFICATION DRY VENTILATION FAN 26 Plus button Increases the target temperature value in COOLING...

Page 9: ...k the proper fit of the exhaust air hose In case of kinks bends or blockage in the hose exhaust air cannot be discharged Clear the way for the exhaust air Check the air filter for dirt If required cle...

Page 10: ...supply is unstable and deviates from the values on the nameplate by more than 10 Connect the device to a power supply conforming to the data on the nameplate Power supply is too low or load is too hig...

Page 11: ...tec Pump does not operate or condensate cannot be discharged Contact Trotec The rubber stopper at the condensate outlet is not properly attached Check the rubber stopper for tight fit Refrigerant leak...

Page 12: ...oling and air conditioning or by Trotec Condensate discharge In COOLING and DEHUMIDIFICATION mode condensate is formed which is mostly discharged via the exhaust air Remaining condensate accumulates a...

Page 13: ...by a reduced cooling capacity see chapter Errors and faults Caution Ensure that the air filter is not worn or damaged The corners and edges of the air filter must not be deformed or rounded Before re...

Page 14: ...ng manual Local air conditioner PAC 2000 E EN Exploded assembly drawing Note The position numbers of the spare parts differ from those describing the positions of other parts mentioned in this operati...

Page 15: ...urther information is provided on the nameplate Dispose of the refrigerant appropriately and according to the national regulations Pos no Spare part Pos no Spare part Pos no Spare part 1 Front Panel A...

Page 16: ...uch pro Stunde Electricity Consumption QSD kWh 60 min 0 8 Nennleistung im K hlbetrieb Nom Power Prated kW 2 1 Nenn Leistungsaufnahme im K hlbetrieb Nom Power Consumption PEER kW 0 95 Leistungsaufnahme...

Page 17: ......

Page 18: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...