Trotec 1180000090 Original Instructions Manual Download Page 10

10

EN

Ozone generator Airozon^®^ 14 ECO

Errors and faults

The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.

The device does not start:

Check the power connection.

Check the power cable and mains plug for damage.

Check the on-site fusing.

Switch the fuse back on or have a defective fuse replaced
by a specialist company.

Wait for 10 minutes before restarting the device. If the
device is not starting, have the electrics checked by a
specialist company or by Trotec.

The device is very loud:

Position the device on a dry, firm and level surface.

Check whether the fan and its bearing for damage. If you
detect any damage, have the device checked by a certified
specialist workshop.

The odour nuisance persists after the completed
purification process with the same intensity:

Have the device checked by a certified specialist
workshop.

The device still does not operate correctly after these
checks:

Please contact the customer service. If necessary, bring the
device to an authorised specialist electrical company or to
Trotec for repair.

Maintenance

Activities required before starting maintenance

Warning of electrical voltage

Do not touch the mains plug with wet or damp hands.

Make sure that the device is switched off.

Hold onto the mains plug while pulling the power cable out
of the mains socket.

Warning
Risk of injury caused by inhalation of ozone!

After the device has stopped operating, wait until the
end of the calculated regeneration period (see
Shutdown chapter) to make sure that the ozone
concentration has fallen below the stipulated value
before performing maintenance and cleaning work.

Care and maintenance must be performed on a regular basis to
ensure the proper functioning and failure-free operation of the
device.
The type and frequency of the maintenance tasks fundamentally
depends on the operating environment as well as on the
duration and type of use.
In the course of using the device, dust and moisture can
accumulate in or on the components which may compromise
functionality and efficiency.
In rooms with a high volume of dust and dirt or after fire
damage restorations (high moisture level) you should already
check the need for maintenance after only a few applications.
In dry surroundings e.g. hotels or as part of car valeting one can
assume a maintenance rate of several months.

Criteria for determining the maintenance interval

Device operation takes place:

frequently and several hours at a time

on many days per month

in excessively dirty surroundings

in humid rooms

Regardless of the described operating conditions you should
perform maintenance work if one or more of the following signs
become apparent:

increased noise level during operation of the fan

heavily contaminated air filter

dirty electrode (recognizable by: The hissing sound
produced during ozone generation dies away.)

Summary of Contents for 1180000090

Page 1: ...TRT BA AIROZON 14ECO TC2020 16 002 EN AIROZON 14 ECO EN ORIGINAL INSTRUCTIONS OZONE GENERATOR...

Page 2: ...ore starting or using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings...

Page 3: ...rators The device uses ozone for air purification It is a gas that due to its oxidative characteristics can cause severe health damage if inhaled Direct exposure to and intake of ozone is toxic for hu...

Page 4: ...mains plug with wet or damp hands Hold onto the mains plug while pulling the power cable out of the mains socket Warning Dangers can occur at the device when it is used by untrained people in an unpro...

Page 5: ...UV radiation It is these atoms that can react with the oxygen molecules to form ozone O3 In case of a high solar irradiation ozone forms involving other air pollutants The nitrogen oxides NOx from au...

Page 6: ...he mains plug while pulling the power cable out of the mains socket If the device was previously in use wait until the end of the calculated regeneration period see Shutdown chapter before transportin...

Page 7: ...ground Position the device as close as possible to the centre of the room to ensure an optimum air circulation When positioning the device keep a sufficient distance to heat sources Make sure that no...

Page 8: ...t an odour neutralization air purification Warning Risk of injury caused by inhalation of ozone The following symptoms could be indicative of poisoning or an irritation caused by ozone eye irritations...

Page 9: ...s proteins with nitrogen and sulphur vomit 360 720 Please contact the Trotec customer service if you like to use the device for disinfection purposes Switch off Warning Risk of injury caused by ozone...

Page 10: ...ling the power cable out of the mains socket Warning Risk of injury caused by inhalation of ozone After the device has stopped operating wait until the end of the calculated regeneration period see Sh...

Page 11: ...aning agents Make sure that no water can enter or remain inside the housing Replacing a fuse The fuse must be replace once it is defective or no longer works correctly Please proceed as follows to rep...

Page 12: ...V Frequency 50 Hz Max nominal current 0 8 A Max power input 180 W Ozone output 7 g h 14 0 g h Air flow rate 168 m h Sound pressure level at a distance of 3 m 45 dB A Dimensions depth x width x height...

Page 13: ...EN 13 Ozone generator Airozon 14 ECO Circuit diagram L N E TIMER FAN Ozone Generator Power 1 FU Ozone Generator Power 2 Indicator light...

Page 14: ...spare parts differ from those describing the positions of the components mentioned in these instructions 1 2 3 4 5 6 7 8 9 10 11 No Spare part No Spare part 1 handle 7 Ozone power supply 2 cover 8 Tim...

Page 15: ...he contents of the declaration of conformity The signed declaration of conformity can be found at https hub trotec com id 44534 Declaration of conformity in accordance with the EC Machinery Directive...

Page 16: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: